IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 36 documents. Displaying 25 entries per page.


A short note on the subject of pretreatment decay in wood
1984 - IRG/WP 1245
The paper reviews five national standards for wood utility poles and some literature that concerns the problems of pretreatment decay. Finally it is proposed to form a new sub-group to study that problem....
J A Taylor


Remedial treatment of joinery. Comparison of distribution of organic solvent preservative and ammonium bifluoride
1978 - IRG/WP 3115
It is some years since it was recognised in the United Kingdom that there was a problem of premature decay in untreated external joinery. Consequently, recommendations for preservative treatment were made by the Building Research Establishment, Princes Risborough Laboratory. In addition, the National House-Building Council has also included the preservative treatment of external joinery in its req...
J M Taylor


Comparisons of differences in electrical conductivity and corrosivity between CCA-oxide and CCA-salt treated wood
1981 - IRG/WP 3178
CCA preservatives have served well in many applications throughout the world. In developed areas it is the preservative in demand for clean dry paintable surfaces with long durability. In developing areas it is widely used for economic and logistical reasons. With the current emphasis on energy resources, the CCA preservatives are gaining greater acceptance as a substitute for hydrocarbon-related ...
J A Taylor


The effect of felling time of year on CCA fixation rate and quality of selected hardwoods
1998 - IRG/WP 98-40116
White birch (Betula papyrifera), poplar (Populus sp.) and red maple (Acer rubrum) trees were harvested in winter, in spring, before the leaves flushed, after leaf flush and later in the summer. Sapwood discs were cut from the freshly felled trees, dried and cut into 25 mm and 19 mm cubes. The cubes were pressure impregnated with CCA-C and fixed under high relative humidity and at 50°C or at room ...
Y T Ung, A Taylor, P A Cooper, D P Kamdem


Mold susceptibility of oriented strandboard made with extracted flakes
2008 - IRG/WP 08-40402
As part of a larger study on the manufacture of oriented strandboard (OSB) using hot-water-extracted flakes, the mold susceptibility of extracted-flake and un-extracted-flake OSB was assessed using the standard ‘mold box’ test. OSB made with extracted flakes was much less susceptible to mold. This suggests that the extraction of hemicelluloses and other carbohydrates from wood for the producti...
A M Taylor, O Hosseinaei, Siqun Wang


An Open Letter to Proponents of CLT/Massive Timber
2016 - IRG/WP 16-40755
We present an Open Letter that discusses the need to address the potential for biodeterioration in CLT/Massive timber structure. We invite members to review and sign the document. We also welcome suggestions for potential recipients....
A Taylor, J Lloyd, T Shelton


Effect of extractive fractions of Thuja plicata and Chamaecyparis nootkatensis heartwood on Coptotermes formosanus
2004 - IRG/WP 04-10535
Heartwood of some species has natural resistance to attack by termites due to the presence of toxic and/or repellent extractives, but the role of individual extractives in termite inhibition is poorly understood. Developing a better understanding of which extractives are most effective against termites may be useful for the identification of improved termite management strategies. The effect of se...
A Taylor, B L Gartner, J J Morrell, K Tsunoda


Effects of deck washes and brighteners on the leaching of CCA components
1999 - IRG/WP 99-50128
Small CCA treated Southern pine decks were exposed to natural weathering and the CCA leaching characteristics determined by analyzing the collected rain drippage over several rain events. The decks were then treated with a number of commercial deck washes/brighteners and the CCA components in the wash solution compared to that from water wash only. Washes containing phosphoric acid, citric acid an...
A Taylor, P A Cooper, Y T Ung


Effect of humic acid on leaching of CCA from treated wood
2000 - IRG/WP 00-50151
Laboratory studies indicate that relatively high concentrations (1.000 - 10.000 ppm) of humic acids can increase the leaching of chromium and copper from CCA-C treated wood, and that copper is most affected. They also show that leaching with natural water samples can result in higher leaching of all components than leaching with distilled water. Evaluation of CCA component retentions and mass bala...
P A Cooper, D Jeremic, J L Taylor, Y T Ung


Kiln drying of poles as a means of solving the problems of pre-treatment decay in poles
1985 - IRG/WP 1263
The concept that pre-treatment decay can cause wide variation in the treatability of wood and especially wood poles has caused much discussion and debate in wood preservation circles. Yet it seem only logical that if decay has effected the strength characteristics of the wood and caused a differential moisture content in the wood the treatment of the end product will be highly variable and the lon...
J A Taylor


Waterborne preservative treatability of tamarack (Larix laricina (Du Roi) K.Koch)
1998 - IRG/WP 98-40112
Eastern larch or tamarack (Larix laricina (Du Roi) K.Koch) lumber from New Brunswick, Canada was evaluated for preservative treatability with chromated copper arsenate (CCA-C) and ammoniacal copper arsenate (ACA). The fixation and leaching characteristics of CCA-C treated tamarack sapwood and heartwood were also evaluated. CCA-C penetration into both sapwood and heartwood was poor. ACA fully penet...
A Taylor, Y T Ung, P A Cooper


Effect of climate, species, preservative concentration and water repellent on leaching from CCA-treated lumber exposed above ground
2001 - IRG/WP 01-50178
Few studies have examined leaching of chromated copper arsenate (CCA) from treated wood in above ground exposures due to the assumption that leaching is less severe compared to wood in continuous contact with soil or water. However, a significant portion of CCA treated wood is used for above ground applications, exposing considerable volumes of the preservative to precipitation and potential leach...
J L Taylor, P A Cooper


Evaluation of the efficiency of industrial kiln type CCA fixation chambers
1996 - IRG/WP 96-40063
Six commercial CCA treating plants in Canada were assessed for the fixation efficiency of their hot air fixation chambers. The wood temperature was measured with thermocouples over the fixation period at different locations in the chamber and at the end of the fixation cycle, the degree of chromium fixation was determined by a boring leaching procedure. There was a great variation in the effective...
A Taylor, P A Cooper


Effects of pre-harvest girdling on selected properties of red pine, red maple and Eastern larch
1999 - IRG/WP 99-40137
Trees of three species - tamarack (Larix laricina), soft maple (Acer rubrum) and red pine (Pinus resinosa) - were girdled immediately below the crown,one to two years before felling. The wood from these trees was compared with wood taken from un-girdled control trees felled at the same. Sapwood and heartwood, from the controls, and from above and below the girdle of treated trees, were examined fo...
A Taylor, P A Cooper


Examination of power poles by computerized tomography
1980 - IRG/WP 2142
The technique known as computed axial tomography (CAT or CT) has become widely known because of the success it has achieved in medical imaging and diagnostics. It has now been used to give non-destructive crosssectional pictures of a variety of industrial objects, including wooden power poles, with a spatial resolution of about 1 mm (0.04 in.). It is obvious the benefits that would be derived from...
J A Taylor, I L Morgan, H Ellinger


Residual CCA levels in CCA treated poles removed from service
2000 - IRG/WP 00-50152
Fifty-two CCA treated poles removed from service after 1 - 50 years were sampled at different depths from their below ground and above ground zones and the preservative levels and mass balances related to the location in the pole and pole age. Generally CCA retentions were still well above the toxic threshold for decay in even the oldest poles. This confirms the good leach resistance of CCA and th...
P A Cooper, D Jeremic, J L Taylor


Natural durability of tamarack (Larix laricina (Du Roi) K. Koch)
1998 - IRG/WP 98-10277
Eastern larch or tamarack (Larix laricina (Du Roi) K. Koch) lumber from New Brunswick, Canada was evaluated for heartwood natural durability according to ASTM D2017-81. The natural durability of tamarack heartwood exposed to two brown rot fungi, Gloeophyllum trabeum and Postia placenta was low and generally inferior to that of the heartwood of spruce (Picea sp.) and white pine (Pinus strobus L.) a...
U Srinivasan, A Taylor, P A Cooper


Water analysis in chemicals, wood or chemically treated wood using a new analytical method for selective water detection
2006 - IRG/WP 03-30391
Water or moisture content analysis can be a challenging task in many applications. However, knowing accurately the type of water which can be found in a given sample or product can provide important information about a chemical compound used for wood treatment and especially about the treated wood sample. Moisture content in wood plays an important role in fungal growth and it needs to be extensi...
R Craciun, D Taylor


Effect of ozone treatment on survival of termites and wood decay fungi
2007 - IRG/WP 07-40365
There is increased concern about the potential for transport of invasive pests on or in untreated wood. Current regulations utilize heating or fumigation as mitigation tools, but both have drawbacks that have stimulated interest in new phytosanitation methods. Ozone fumigation has been shown to control insects, fungi and bacteria on a variety of agricultural products. Systems for the controlled g...
A M Taylor, L J Mason, J J Morrell


Near infrared spectroscopy for the quantification of wood preservatives
2008 - IRG/WP 08-20391
Near infrared (NIR) spectroscopy is a rapid, flexible, inexpensive and non-destructive technology that has many applications, including the evaluation of many wood properties. Initial studies have indicated the potential to apply NIRS for the quantification of wood preservatives. However, further evaluation with borate and azole preservative systems has revealed that NIRS technology is challenged ...
A M Taylor, Seung H Baek, Myong K Jeong, J D Lloyd, J J Morrell


Preventing decay in termite monitoring stations
2010 - IRG/WP 10-30546
In-ground monitoring stations and termite baits are widely used in the southern United States with the intent of detecting and eradicating subterranean termite activity near buildings. These stations comprise a wood (or other cellulose material) substrate (monitor) and perhaps a termiticidal toxicant (bait) held in a plastic cage that allows for both easy examination and access by termites. The us...
A M Taylor, Jae-Woo Kim, S Duarte, L Nunes, J D Lloyd


Ambient-temperature borate dip-diffusion treatment of green railroad crossties
2011 - IRG/WP 11-40556
In the USA, borates are increasingly being applied prior to air seasoning and creosote treatment of railroad ties (railway sleepers). Borates are typically applied to green ties by vacuum pressure application at 1 to 10% disodium octaborate tetrahydrate (DOT) concentration or by traditional dip-diffusion treatments at elevated temperatures. Higher temperatures are used to maintain the 30 to 50% so...
Jae-Woo Kim, A M Taylor, C Köse


Eastern redcedar included sapwood: Resistance to mold and termites under laboratory conditions
2012 - IRG/WP 12-10765
The heartwood of eastern redcedar (Juniperus virginiana) frequently contains areas of light-colored wood. This “included sapwood” is considered to be a defect by some manufacturers. In this study, sapwood, included sapwood and heartwood samples from five eastern redcedar trees were exposed to mold fungi or to subterranean termites in a no-choice feeding test. Extractives content was also measu...
C Köse, A M Taylor


Decay factors in termite in-ground monitoring stations
2012 - IRG/WP 12-10775
Subterranean termites are serious pests of wood in service in much of the world. One of the most common techniques for monitoring and controlling termites is the use of in-ground monitoring stations which comprise a wood or other cellulosic material monitor (cellulosic matrix) and/or a termiticide bait held in a open plastic holder so facilitates examination and the termite access. Wood and other ...
S Duarte, A M Taylor, Jae-Woo Kim, J D Lloyd, M Duarte, L Nunes


Preliminary evaluation of degradation patterns in wood samples from the Yenikapı shipwrecks
2013 - IRG/WP 13-10798
The uncovering of several shipwrecks during the excavation of the Marmaray Rail Tube Tunnel Project in Istanbul provides an important opportunity to evaluate waterlogged woods buried for centuries. Identification of these woods showed that a variety of species was used in the ships. One shipwreck (a galley) from the Yenikapı Marmaray was examined using electron microscopy. The micrographs rev...
C Köse, A M Taylor


Next Page