IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 129 documents. Displaying 25 entries per page.


Determination procedure for wood preservatives in waste wood - statistics of sampling and analysis
1998 - IRG/WP 98-50121
In a RTD research programme funded by the German Federal Environmental Agency (UBA - Report No. 126-06-010103) a standardised and validated procedure was developed for sampling and analysing wood preservative components in waste wood. For this investigation a realistic quantity of waste wood from house demolition was used and 80 components analysed. The examination of single wood pieces and woodch...
P Stolz, J Krooss, U Thurmarm, R-D Peek, H Giese


Microbial decomposition of salt treated wood
1993 - IRG/WP 93-50001-22
Specialized microorganisms which are able to convert fixed inorganic preservatives from treated wood into water soluble components are investigated. A number of brown rot fungi like Antrodia vaillantii have been isolated from cases of damage and examined under unsterile conditions with CCA-, CCB-, CCF- and CC-treated wood at retention levels of at least 50% higher than recommended for wood in grou...
R-D Peek, I Stephan, H Leithoff


Composting of waste building up in sawmill dipping basins
1990 - IRG/WP 3570
We have studied composting of waste building up in dipping basins at sawmills although this waste can also be disposed of by incineration. Controlled composting within the sawmill area seems to be a feasible method. Another possibility is to accomplish composting directly at the local dumping site. Waste containing antistain chemicals is generally classed as hazardous. It cannot therefore be place...
I A Linderborg, U Ek


Biological detoxification of wood treated with salt preservatives
1992 - IRG/WP 92-3717
The use of microorganisms that are capable to convert chemically fixed inorganic preservative complexes from impregnated wood waste into watersoluble components is investigated. A number of fungi were isolated from deteriorated and initially well-treated wood. They revealed an exceptionally high production of organic acids (pH 2). The fungi were identified and used together with others of the same...
I Stephan, R-D Peek


Tendency of the preservative use for impregnation industries in Japan
1998 - IRG/WP 98-50101-05
In Japan, since 1997, the acceptable limit of the arsenic in the waste water become to 0,1 mg/l and the additional regional severer restriction can be established. In this reason, Japanese wood preservation industries intend to use other than CCA, like DDAC, ACQ, Tanalith CuAz, copper-naphthate and zinc-naphthenate, as replacing from CCA. In Jan-June 1997, the share of CCA preservatives was less t...
K Suzuki


Analysis of contaminants in waste wood
2001 - IRG/WP 01-50179
Waste wood is increasingly used as fuel in Sweden. It is of Swedish origin as well as imported, Mainly from Germany and the Netherlands. The major chemical contaminants are surface treatments (paints etc) and wood preservatives. The surface treatments contribute in particular to contaminants of zinc and lead. In some cases zinc has been found to cause severe deposits in the furnaces. Surface treat...
J Jermer, A Ekvall, C Tullin


Co-incineration of CCA-treated wood and Municipal Solid Waste in MSWI plant
2005 - IRG/WP 05-50224-19
The Norwegian Association of Energy Users and Suppliers (Norsk Energi) have carried out incineration tests with addition of 10 % by weight CCA-treated wood waste to municipal solid waste in a MSWI plant. The objective with the test was to determine emissions and composition of bottom ash. The incineration test was done at the Klemetsrud plant in Oslo The main conclusions are: -No significant inc...
D Borgnes, B Rikheim


Recycling CCA-treated poles with Charterm
2005 - IRG/WP 05-50224-17
After 10 years of Research and Development, the first “Chartherm” industrial unit is now operating since nearly half a year, thanks to Thermya SA, engineering company, current owner of all the “Chartherm” process Patents and Rights. In accord with the recycling contracts signed with several French major companies, the “Chartherm” plant, located near Bordeaux, recycles every day severa...
J-S Hery


Tolerance of Wood Decay Fungi to Commercial Copper Based Wood Preservatives
2002 - IRG/WP 02-30291
Due to the use of copper based preservatives like CCB or CCA for more than a century, copper tolerant fungi have appeared in some European countries in recent times. It is therefore important to find out whether this phenomenon is specific for only classical copper ingredients, or generally for all copper based formulation. Thus, we tested the tolerance of three commercial copper based pres...
F Pohleven, M Humar, S A Amartey, J Benedik


The use of preservative containing waste wood as substrate for growing greenhouse crops
1993 - IRG/WP 93-50011
In the Netherlands a large amount of waste wood and wood waste is produced every year. An important part of this amount comes from the pallet and packaging industries. One of the possibilities to re-use this relatively clean material is to convert it into substrates for growing crops in glass houses instead of the commonly used materials such as rock wool and glass wool. In this research, the infl...
W J Homan,H Militz


Solidification - A viable option for the safe disposal of CCA treatment plant wastes
1993 - IRG/WP 93-50001-21
Treatment plant operations generate small quantities of waste materials contaminated with wood preservatives - for example, sludges, contaminated sawdust, yard dirt. A practical system involving the immobilisation of such wastes has been established to assist the operators to safely dispose to landfill sites. The results of cold water and hot dilute acid leaching regimes are described, which simul...
M R Gayles, D Aston


Worker aggregation and baiting for management of subterranean termites
1994 - IRG/WP 94-10052
Environmental concern in the current use of cyclodiene and other chemicals for subterranean termite control had led to search of alternative environmental friendly management strategies. Worker aggregation and baiting are promising strategies. Aggregation is mediated through food recognition, attraction to some synthetic chemicals such as d-camphor, cinnamyl alcohol and sereral styryl compounds, s...
P K Sen-Sarma


Electrochemical removal of Cu, Cr and As from CCA-treated waste wood
2001 - IRG/WP 01-50166-18
CCA-treated waste wood poses a potential environmental problem due to the content of copper, chromium and arsenic. This paper presents the results obtained by electrodialytic remediation of CCA-treated waste wood. It is found that more than 90% Cu, and approximately 85% Cr and As was removed from the wood during the remediation. Thereby the concentration of copper in the wood is reduced from app. ...
I V Kristensen, L M Ottosen, A B Ribeiro, A Villumsen


Bioremediation of surfactant contaminated waste
1996 - IRG/WP 96-50070
The objective of this work was to determine the potential of fungi as agents for the bioremediation of wastes (particularly wood and soil) contaminated with quaternary ammonium compounds (QACs). Until now only bacteria have been investigated for this purpose. Tolerant strains of Gliocladium roseum and Verticillium bulbillosum were studied for their ability to degrade the following QACs: didecyldim...
J L Bürgel, J Dubois, J N R Ruddick


Sawn timber of fir (Abies alba Mill.) - Treatability and usability for the Hazard Classes 3 and 4
1999 - IRG/WP 99-40147
Within a national research project, tests on the treatability on sawn timber of fir (Abies alba Mill.) in oscillation pressure, vacuum pressure and double-vacuum processes have been worked out with 95 trunks taken from 3 different altitude levels (up to a height of 590 metres, 600 to 990 metres and over 1000 metres) and from 4 different regions of Switzerland. As the treatability of round wood can...
E Graf, T Bör


Characteristics and quantity of impregnated wood waste in Germany
1995 - IRG/WP 95-50041
The disposal of wood waste in Germany is one of the main problems not only for the wood preservation industry but also for all concerned with wood waste. Data on characteristics and quantity of wood waste are still needed. Based on criterions given in a previous paper (IRG/WP 93-50006), several assortments have been characterized with regard to their hazardous potential and their logistical aspect...
A Voss, H Willeitner


Preliminary evaluation of the answers to the 2nd IRG/WP-questionnaire on the state of pollution control in the field of wood preservation
1982 - IRG/WP 3209
This preliminary evaluation of the answers to the 2nd IRG/WP-Questionnaire only gives a general survey on those questionnaires which the author received until April 30th, 1982. Details, such as correlations between importance of wood preservation and pollution control, as well as a comparison of the answers with those to the first questionnaire (Doc. IRG/WP/369), could not be considered due to lac...
H Willeitner


The effect of a chelator mediated fenton system on activation of TMP fibres and decolorization of synthesized dyes
2004 - IRG/WP 04-50223
The purpose of this work is to improve our current knowledge of the non-enzymatic mechanisms involved in the brown rot degradation of wood, but also to study the potential applications of a chelator-mediated Fenton system in activation of wood fibers and decolorization of synthesized dyes. In this work, Electron Spin Resonance (ESR) spin-trapping techniques were used to study the generation of hyd...
Yuhui Qian, B Goodell, J Jellison


Possibility and problems of characterizing treated wood after service with regard to disposal
1993 - IRG/WP 93-50006
For the disposal of wood waste under ecological conditions, information about its hazardous potential and the logistic aspects for its handling is needed. The main criterion to evaluate the hazardous potential besides the determination of the type and quantity of active ingredients in the wood will be the degree of mixture with different treated or untreated timber. Assortments can be homogeneous ...
A Voss, H Willeitner


Health and safety regulations on the use of wood preservatives in Switzerland
1980 - IRG/WP 3148
There is not any doubt that the chemical protection of wood (besides the architectional-constructional wood protection) is of utmost importance for the increase of the durability of technically used timber. The toxic properties of wood preservatives make certain legal regulations necessary for the protection of human beings, animals and the environment. Thereby wood preservatives fall under the po...
O Wälchli


Biosorption of metals for wood waste effluent clean up
1997 - IRG/WP 97-50090
The common filamentous fungi can sorb metal ions from aqueous solutions. The biosorption of metal ions like copper Cu2+, chromium Cr6+ and arsenic As5+ by dead fungal mycelia was investigated. Two industrial fermentation byproducts are tested: Mucor miehei and Aspergillus oryzae. The adsorption of metal ions depends on parameters such as chemical treatment of fungi before biosorption (acid or basi...
S Legay, G Labat


Environmental situations on wood preservation industries in Japan
1995 - IRG/WP 95-50040-21
Because of environmental civil oppinions, Ministry of Agriculture, Forestry and Fisheries in Japan, reviesed "the standards for sawn lumber" in 1994. For the possibilities of the use of preservatives out of CCA, by the using of the hazard levels, new products like ACQ, DDAC and emulsified zinc-naphthenate can be used in the standards. Since 1994, the permitable limit of the arsenic in the waste wa...
K Suzuki


Management strategies for the disposal of CCA-treated wood
2000 - IRG/WP 00-50155
A two-fold management strategy is presented for the disposal of wood treated with chromated copper arsenate (CCA). The first part focuses on the use of alternative wood treatment preservatives. The second part of the management strategy addresses short-term disposal issues (less than 25 years) by developing new methods to handle the waste. A set of seven alternative wood preservatives were evaluat...
H M Solo-Gabriele, T G Townsend


The use of light organic solvents in industrial wood preservation - an environmental perspective
1995 - IRG/WP 95-50040-22
The paper examines the evolving regulatory environment concerning the use of hydrocarbon solvents in industry and, in particular, the European wood preserving sector. The implications of the proposed EU Directive on industrial solvent use are explained and possible responses to such regulation examined, including process modification, product changes and emission abatement, where necessary. The de...
G A Ewbank


Chemical analysis of wood waste - The problem of sampling
1999 - IRG/WP 99-20168
A quantitative analysis of the content of active substances in wood is often demanded in quality control after processing and for the proper waste management. As a measure for quality control, analysis has the advantage that the type of preservative is known and assumptions can be made about its distribution in the treated wood.W aste wood may have been treated by a wide range of organic and inorg...
A Peylo, R-D Peek


Previous Page | Next Page