IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 109 documents. Displaying 25 entries per page.


Cuticular hydrocarbons for species determination of tropical termites
1990 - IRG/WP 1465
Insect species have unique mixtures of cuticular hydrocarbons in the protective wax of their integument. We use hydrocarbons to evaluate similarities among termite populations. Our assumption is that colonies with similar hydrocarbon profiles are closely related. We have collected Reticulitermes in California from areas suspected to have only Reticulitermes hesperus or Reticulitermes tibialis. The...
M I Haverty, M Page, B L Thorne, P Escoubas


The evaluation of the occurrence of soft rot in creosoted wooden poles
1988 - IRG/WP 1368
The occurrence of soft rot decay in creosoted wooden poles for overhead power lines was investigated by collection of field samples, their subsequent microscopic examination and statistical analysis of the data collected. Examination of samples collected from 296 poles revealed that approximately 15% of the pole population studied (Eastern Electricity Board) showed the presence of soft rot decay. ...
A Wylde, D J Dickinson


The reliability of colouring methods for the determination of biflourides and boron in spruce wood
1994 - IRG/WP 94-20036
From practical reasons, qualitative spraying methods are widely used for the detection of bifluorides and boron in wood. The main aim of this research was to detect whether the concentration of the active ingredient in the coloured area is equal or greater than the toxic value against basidiomycetes. Both colouring methods, Z-A reagent for fluorides and curcuma reagent for boric acid, are a reliab...
R Grell, M G Sanders, W J Homan, H Militz


Summarized comparison of four techniques for detecting defects in poles
1979 - IRG/WP 2126
Since our discussions in open session of Working Group II at Peebles, a number of workers in Australia have collaborated in comparing the efficacy of X-ray, sonic testing, or resistivity measurements for detecting internal defects in poles. The purpose of this circular is to draw to your attention some of the results, in summary form. No attempt has been made to compare techniques. More detailed a...
H Greaves


Study of the degradation of retified wood through ultrasonic and gravimetric techniques
1994 - IRG/WP 94-40030
One of the non-polluting processes that increase the natural durability of wood is a thermal treatment in an atmosphere poor in oxygen, producing what is normally denominated "retified wood". In this study the validity of a non-destructive technique (ultrasound) in order to determine the biodegradation suffered by wood across time has been studied. For this reason, the behavior of a wood species (...
D T De Troya, A M Navarrete


Determination of fixation properties by bioassays - A proposal for the assessment of safety indexes in wood protection
1990 - IRG/WP 3566
In the determination of environmental effects of chemicals tests with fishes, daphnia and algae have proved to be practicable. With respect to wood protection such bioassays are suitable to control effects of treated timber against aquatic organisms. By using the fish-acute-toxicity-test the development of a laboratory test method is described for the checking of the fixation rate of a copper-chro...
H-W Wegen


Development of a turbidity method for the determination of water repellent in CCA treatment solutions
2000 - IRG/WP 00-40177
The use of aqueous water repellent emulsion formulations has increased significantly in the wood treatment industry. These are primarily used to enhance the weathering characteristics of wood products treated with water borne preservatives systems used in exterior above ground exposures. However, they are also used in pole treatments to improve the climbing characteristics and in low VOC millwork ...
P J Walcheski, L Jin


A comparison of inductively coupled plasma spectroscopy and neutron activity analysis for the determination of concentrations in wood
1993 - IRG/WP 93-10048
As wood decays the ionic composition changes, with increases often being seen in the concentrations of Ca, Mg, Fe, Mn and sometimes K. The concentration of eight cations in red spruce sapwood and heartwood samples was determined independently by inductively coupled plasma spectroscopy (ICP) and by neutron activation analysis (NAA) as part of an effort to standardize our analytical procedures and c...
J Jellison, J Connolly, K C Smith, W T Shortle


ATP assay for the determination of mould activity on wood at different moisture conditions
1992 - IRG/WP 92-2397
To determine fungal responses to fungicides and environmental conditions and for detection of microbial activity in wood, sensitive and objective methods are needed. We have developed a suitable assay based on analysis of adenosine triphosphate (ATP) by using the luciferin-luciferase reaction. With the aid of this assay the activity of Penicillium brevicompactum on wood at different RH levels was ...
J Bjurman


Industrial wood preservation in Kenya. Present status – future prospects
2005 - IRG/WP 05-30385
Although some 50 years old, industrial wood preservation in Kenya does not appear to have technically, scientifically, and commercially evolved and contributed to significantly extend service lives of timbers, protect health and the environment, and curb unnecessary over-exploitation of forests. The population of the country has increased by 530% over the past 50 years; regular excisions have red...
R Venkatasamy


Longterm monitoring of termite activity on multiple feeding sites: a laboratory method intended for the determination of attractant/repellent properties of wood preservatives and baits
2001 - IRG/WP 01-20225
A method is introduced allowing the continuous monitoring of the activity of a small laboratory termite- colony at 8 different feeding sites simultaneously. The test assembly consists of a small central polycarbonate-tube containing a colonie of Reticulitermes santonensis (de Feytaud) beeing connected with 8 external feeding sites by small glass-capillaries. The termites passing through the glass ...
M Pallaske, E Graf, H Takiuchi


Determination of total fluoride and boron in preservative-treated wood fluoride by ion selective electrode without steam distillation, and boron colorimetrically using azornethine-h
1998 - IRG/WP 98-20135
An analytical method was developed to determine total fluoride and boron in wood treated with aqueous or solid diffusing fluoride or borate-fluoride formulations. Ground wood was mixed with 30% sodium hydroxide solution and oven-dried for 2 hours before furnacing at 600° C for 1 hour. The cool fused product was dissolved in hot water, transferred to a plastic beaker and neutralised. Fluoride was ...
P A Collins, M J Kennedy


Determination of absorption, accumulation and transport of copper in mycelium of some wood decay fungi
1999 - IRG/WP 99-10323
Copper compounds are common wood preservatives. However, tolerance of some wood decay fungi to copper compounds has been observed recently. Therefore, we tried to elucidate possible causes of this phenomenon. We investigated uptake, accumulation and secretion of copper in the mycelium of potentially copper tolerant fungi (Antrodia sp.) and non tolerant fungus Trametes versicolor. We observed that ...
F Pohleven, S Breznikar, P Kalan, M Petric


Evaluation of the pulsed-current resistance meter (Shigometer®) for determination of the internal condition of utility poles
1979 - IRG/WP 2128
A number of Telecom poles, which had been removed from service to be replaced by a radio link, were inspected using an electrical resistance meter (Shigometer®). These poles were creosoted, non-durable Victorian species in service in New South Wales. Six of these poles, chosen to represent various internal conditions typical of the range of the population tested, are discussed here. Data, from tr...
J D Thornton, W G Seaman, M McKiterick


Determination of the water sorption properties and preliminary results from field tests above ground of thermally modified material from industrial scale processes
2004 - IRG/WP 04-40279
In this study the differences in moisture behavior and durability above ground of heat treated wood originating from different European industrial heat treatment plants by means of the water sorption properties as well as field tests were examined. The manufacturers of heat treated material were: PLATO Hout B.V./Netherlands, Thermo Wood (Premium wood)/ Finland and Menz Holz/ Germany, where Oil-...
C R Welzbacher; A O Rapp


Zur Analytik von Pentachlorphenol und Tetrachlorphenol in der Luft und im Urin. [On the analytics of pentachlorophenol and tetrachlorophenolin the air and in urine]
1979 - IRG/WP 3139
Because of its excellent fungicide and insecticide properties PCP has been used for more than three decades in the field of wood preservation. Recently, however, its application has been criticized repeatedly. The motives for criticism were diseases, the origin of which was supposed to be closely connected with the use of pentachlorphenolic wood preservatives. The quantitative evidence of this sub...
A Dahms, W Metzner


On-site test for indicative determination of leaching of components of preservatives from treated timber
1993 - IRG/WP 93-50001-12
In the late eighties the environmental concern about treated timber increased and it is still a hot issue in the Netherlands. From the environmental point of view three phases in the timbers life cycle can be distinguished: - the production phase - the service life - the waste phase. In the Netherlands at this moment much emphasis is laid on the production phase. In 1992 this has led to a new legi...
W J Homan, H Militz


Gas chromatographic determination of 1,8-naphthalimide, N-Hydroxy-1,8-naphthalimide (N,N-naphthaloylhydroxylamine) and the sodium salt of N-Hydroxy-1,8-naphthalimide
2003 - IRG/WP 03-20259
A number of naphthalimide (NI) derivatives are used as efficient laser dyes, in medicine or in scanning electron microscopy. Only N,N-naphthaloylhydroxylamine (NHA) has been shown to be an effective wood preservative against wood decay fungi and termite damage. However, limited information is available concerning the analytical detection of NI-derivatives in treated timber. There is a clear need ...
E Melcher, F Green III


Determination of ethanolamine in impregnated wood
2000 - IRG/WP 00-20198
Leaching of copper based preservatives from wood is usually prevented by adding chromium compounds to copper containing formulations. It seems that suitable substitutes for chromium fixation agents may be amines. In this paper, we report our results on interactions between copper(II) octanoate and ethanolamine (C2H7NO, 2-aminoethanole) with wood or its components. A part of ethanolamine from a woo...
M Humar, M Petric


Determination procedure for wood preservatives in waste wood - statistics of sampling and analysis
1998 - IRG/WP 98-50121
In a RTD research programme funded by the German Federal Environmental Agency (UBA - Report No. 126-06-010103) a standardised and validated procedure was developed for sampling and analysing wood preservative components in waste wood. For this investigation a realistic quantity of waste wood from house demolition was used and 80 components analysed. The examination of single wood pieces and woodch...
P Stolz, J Krooss, U Thurmarm, R-D Peek, H Giese


Application of (n-a)-radiography for determination of boron in wood impregnated with boron-containing antispetics
1975 - IRG/WP 351
The method of (n-a)-radiography for quantitative determination of boron is based on creation of defective regions (tracks) in a polymer (the detector), which form during passage of a particles through the detector, these particles being produced in the reaction 10B(n, a)7Li when the test specimen in contact with the detector is irradiated with neutrons. Etching of the detector with an appropriate ...
N A Dubinskaya, M Ya Tsel'millere


The influence of the location of a wood defect on the modulus of elasticity determination in wood durability testing
2004 - IRG/WP 04-20287
This study investigates the influence of the location of a wood failure in stakes upon elastic changes observed in beech specimens with the resonance vibration technique. Natural failures were simulated by artificially created defects at different locations of the test stake. The results indicate that the location of an attack in a stake is important for the measurement outcome. When the attack is...
L Machek, H Militz


A novel guide for the determination of the physical properties of wood including kiln drying and full-cell preservative treatment
2004 - IRG/WP 04-20298
An ideal flow chart for the sequential experimental determination of a range of physical properties relevant to wood drying and subsequent preservation was designed as a novel guide to assist wood scientists. In this manner, data assembly and experimental processing are shown. This was designed according to experience and published literature. Aspects emphasised in this review were the physical p...
I Usta, M D C Hale


A survey of the incidence of decay in copper-chrome-arsenate treated trellis support posts used in horticulture in New Zealand
1984 - IRG/WP 1225
Copper-chrom-arsenate treated softwood posts used as trellis support structures in 5 major horticultural districts of New Zealand were systematically examined for presence of decay. Principal crops on properties examined were grapes and kiwifruit; a minority of properties grew hops, boysenberries, and dwarf apples. Occurrence and severity of decay were variable within specific age classes of posts...
M E Hedley, J A Drysdale


A comparison between different accelerated test methods for the determination of the natural durability of wood
1996 - IRG/WP 96-20099
According to the European standard EN 350-1 the natural durability of wood is defined as: "the inherent resistance of wood to attack by wood destroying organisms". This standard also describes how, for certain hazard classes, the durability is determined. The two methods described in this standard are the kolleflask method (EN 113) and the field-stake-test method (EN 252). The EN 113 test gives re...
H Militz, S G L Michon, J E Polman, M Stevens


Previous Page | Next Page