Proposed method for out-of-ground contact trials of exterior joinery protection systems

IRG/WP 2157

J K Carey, D F Purslow, J G Savory

Methods for testing the efficacy of preservative treatments for exterior joinery are described using the format of a European Standard. Commercially used treatments applied to jointed test units (L-joints) which are then protected by conventional finishes are exposed to normal outdoor hazards out of ground contact. Assessment is made a) by determining eventual failure through decay and b) by destructive examination of replicate treated and untreated units, after increasing time intervals, rating comparative performance in terms of wood permeability increase and the progress of microbial colonisation.


Keywords: TESTING; EXTERIOR JOINERY; L-JOINTS; EUROPEAN STANDARD; PRESERVATIVES; TREATMENTS; OUT-OF-GROUND CONTACT; PERFORMANCE

Conference: 81-05-11/15 Sarajevo, Yugoslavia