A critical review of the AWPA standard method (M12-72) for laboratory evaluation to determine resistance to subterranean termites

IRG/WP 1298

J P La Fage, M Jones

The American Wood Preservers' Association standard (M12-72) for evaluation of candidate wood preservatives against subterranean termites is reviewed and suggestions for revision are made. The most serious flaws in the current test procedure involve a failure to recognize inter- and intraspecific variation and a lack of quantification of test results.


Keywords: ISOPTERA; RHINOTERMITIDAE; SUBTERRANEAN TERMITES; LABORATORY BIOASSAYS; VIGOR; TERMITE TESTS; AWPA STANDARD M12-72; INSECTICIDES

Conference: 86-05-26/30 Avignon, France