The use of the Pilodyn for detecting soft-rot decay in CCA treated eucalypt poles

IRG/WP 2251

L E Leightley, G A Willoughby

A 6 Joule Pilodyn unit with 2.5 mm diameter pin was used to inspect CCA treated eucalypt poles, suspected of suffering groundline soft-rot decay. Pole plugs were removed at the inspection region and the amount of soft-rot decay present determined microscopically. High correlation (R² = 0.73) was obtained between the amount of soft-rot and Pilodyn pin penetration. The Pilodyn is recommended as a useful instrument for inspecting eucalypt poles.


Keywords: NON-DESTRUCTIVE TESTING; EUCALYPTUS; CCA; SOFT ROT; POLES; PILODYN; DECAY DETECTION; POKING METHOD; MICROSCOPY

Conference: 86-05-26/30 Avignon, France


Download document (568 kb)
free for the members of IRG. Available if purchased.

Purchase this document