Sampling variation in a copper chrome arsenic treated power transmission pole
1990 - IRG/WP 2351
The Queensland Forest Service routinely samples poles treated at all treatment plants throughout the State. Each treatment plant is issued with a Certificate of Registration and the accompanying documents list the different levels of preservative retention required for performance in various service conditions. The posted levels represent the.minimum permissible, and it is to these concentrations ...
J Norton


Estimation of the population of a sound colony of Coptotermes lacteus (Froggatt)
1988 - IRG/WP 1353
Selecting an area with a high termite hazard is deemed essential in locating field sites in order to screen potential termiticides and wood preservatives. Yet, quantifying termite populations in such sites remains imprecise. There are major problems associated with estimating populations of termites in mound colonies (either free-standing or in trees), and these are briefly discussed. In this pape...
D M Ewart, J R J French


Sampling rates and the probability of detecting defective treatment in the sampling of preservative treated timber
1987 - IRG/WP 2277
When attempting to enforce standards of penetration and retention set for treated timber, the regulating authority must establish a sampling or inspection scheme which will prevent large quantities of substandard product entering the market. On the other hand, the scheme should not penalise treaters for the small quantities of such material which are inevitably produced by any industrial process. ...
M J Kennedy, L E Leightley


A Long-term Observation of Termite Activity in The Nest by Continuous Acoustic Emission (AE) Monitoring
2003 - IRG/WP 03-20280
In order to evaluate the influence of temperature on the termite activity, acoustic emission (AE) monitoring was applied to two nests of Coptotermes formosanus SHIRAKI; a nest in the stem of a standing tree and a nest in the underground of a wooden house, respectively. Temperature change in and around the nests were continuously measured for about one year using thermocouples at four points; the c...
Y Yanase, Y Fujii, S Okumura, T Yoshimura, Y Imamura


The use of modulus of rupture and modulus of elasticity in natural durability testing
1997 - IRG/WP 97-20117
Losses in weight, losses in bending strength and changes in elastic behaviour were assessed in a fungus cellar test with beech wood stakes (Fagus sylvatica). Results were gained after 8, 12, 16 and 20 weeks resp . The outcomes show, that the non-durable species beech is very rapidly attacked by fungi and loses up to 60% of its initial bending strength even within the first 8 weeks. Earlier researc...
L Machek, H Militz, W Gard


A novel device for detecting internal defects in wooden poles
1989 - IRG/WP 2329
The diagnosis of internal defects caused by termites and decay in hardwood transmission poles has been investigated using a novel Automatic Feed Drill (AFD) pole testing device. Internal defects were recognised by changes in drill feed-rate as the automatic air-driven drill traversed its 100 mm working stroke. The instrument is portable, simple to operate and recognises defects instantaneously. Te...
R A Eaton, R S Johnstone


The use of the Shigometer® and Pilodyn® as non-destructive test methods for detecting decay in CCA treated eucalypt poles
1981 - IRG/WP 2153
The groundline condition of sixty C.C.A. treated eucalypt poles comprising six different species was examined using the Pilodyn® and Shigometer®. Although sensitive to the presence of soft-rot decay, the Shigometer® would seem to offer little practical advantage in the eucalypt soft-rot decay situation, since a comparable visual examination could reveal the presence and extent of decay. Initial...
L E Leightley


Influence of sampling on the composition of test solutions
1985 - IRG/WP 2235
For four commercial products of CCB-salts the influence of the kind of sampling on the composition of test solutions has been tested. For each product several 5 g samples have been taken at random, after careful mixing the content of each bottle, and after grinding the whole content. With each sample a 5% test solution was made and analyzed on the content of chromium, copper and boron. Altogether ...
H Willeitner, K Brandt


Evaluation of the pulsed-current resistance meter (Shigometer®) for determination of the internal condition of utility poles
1979 - IRG/WP 2128
A number of Telecom poles, which had been removed from service to be replaced by a radio link, were inspected using an electrical resistance meter (Shigometer®). These poles were creosoted, non-durable Victorian species in service in New South Wales. Six of these poles, chosen to represent various internal conditions typical of the range of the population tested, are discussed here. Data, from tr...
J D Thornton, W G Seaman, M McKiterick


On-site test for indicative determination of leaching of components of preservatives from treated timber
1993 - IRG/WP 93-50001-12
In the late eighties the environmental concern about treated timber increased and it is still a hot issue in the Netherlands. From the environmental point of view three phases in the timbers life cycle can be distinguished: - the production phase - the service life - the waste phase. In the Netherlands at this moment much emphasis is laid on the production phase. In 1992 this has led to a new legi...
W J Homan, H Militz


Proposals for further co-operative studies on determining toxic values against wood-destroying Basidiomycetes
1985 - IRG/WP 2247
Document IRG/WP/2194 reported the status of the programme of co-operative experiments up to and including December 1982. During discussions at IRG-13 in Turkey members endorsed the decision to complete the programme of tests and conduct repeat tests. At IRG-14 in Brisbane the report was noted but no further action agreed. At IRG-15 in Sweden a number of interested parties in the European/Scandinav...
A F Bravery


Determination procedure for wood preservatives in waste wood - statistics of sampling and analysis
1998 - IRG/WP 98-50121
In a RTD research programme funded by the German Federal Environmental Agency (UBA - Report No. 126-06-010103) a standardised and validated procedure was developed for sampling and analysing wood preservative components in waste wood. For this investigation a realistic quantity of waste wood from house demolition was used and 80 components analysed. The examination of single wood pieces and woodch...
P Stolz, J Krooss, U Thurmarm, R-D Peek, H Giese


Detection of Termite Attack to Wood Stakes in a Monitoring Station Using Ceramic Gas Sensors and Acoustic Emission (AE) Sensor
2003 - IRG/WP 03-20271
To evaluate the termite activity in monitoring stations non-destructively, metabolic gas from termites and acoustic emission generated by feeding of termites were measured. Ten cylindrical stations with small wood stakes of Japanese red pine (Pinus densiflora) were buried around a house attacked by Coptotermes formosanus SHIRAKI. A sample air in the station was collected by sucking through a drill...
Y Yanase, Y Fujii, S Okumura, T Yoshimura, Y Imamura, T Maekawa, K Suzuki


A new approach to the maintenance of wooden railway sleepers. (Final Report)
1992 - IRG/WP 92-3724
The micro-environment of wooden railway sleepers was investigated to assess their condition, to determine the necessary treatment, repair and replacement criteria. In the final report the secondary preservative treatment of wooden sleepers with solid boron rods is discussed; the complete development of an in-situ, non-destructive test method based on structural dynamics analysis is described. The ...
W Beauford, A M Brown, D J Dickinson


Non-destructive stress wave measurement of decay and termite attack in experimental wood units
1986 - IRG/WP 2256
The purpose of this study was to determine if stress wave analysis could be used to monitor the degradation of wood specimens exposed to the brown-rot decay fungi (Gloeophyllum trabeum) and of wood specimens subjected to attack by subterranean termites. One hundred fifty 3/4 by 3/4 by 12 in. Southern pine specimens were used for exposure to brown-rot decay fungi and two hundred twenty-five 3/4 by ...
R F Pellerin, R C De Groot, G R Esenther


New approaches to practical evaluation method of bio-degradation of wooden construction - Non-destructive detection of defects using radar technique
2000 - IRG/WP 00-20214
There have been a number of researches and developments on the techniques and apparatus for the nondestructive evaluation of the biological deterioration in wood and wooden constructions, such as decay or insect attack in house, public buildings or in historically important architectures. As for the detection of the decay in wood, techniques using sound in audible or in ultrasonic frequency ranges...
Y Fujii, Y Komatsu, Y Yanase, S Okumura, Y Imamura, M Tarumi, H Takiuchi, A Inai


Laboratory tests on the natural durability of timber methods and problems
1984 - IRG/WP 2217
In literature a large variety of test methods is mentioned to examine the natural resistance of timber against fungal attack. This concerns the kind of sampling as well as the test procedure, the test fungi, the duration of test, and the classification of the resistance according to the test results. These variations, however, are of great influence on the test result. Long term exposure will lead...
H Willeitner


A dynamic approach to assess the modulus of elasticity in wood decay testing
1998 - IRG/WP 98-20139
In this study, the changes in elastic behaviour and mass losses of different hardwood and softwood species exposed to decay in a laboratory soil tests were assessed. Wood decay was monitored using different assessment methods, namely: mass loss and changes in elastic behaviours (MOE) determination. Elastic changes were determined by static and dynamic methods, for the latter, acoustic technique wa...
L Machek, H Militz, R Sierra-Alvarez


Non-destructive detection of the presence and behaviour patterns of wood-destroying insects
1988 - IRG/WP 2302
An apparatus, designed for the automatic recognition of the presence and of specific behaviour patterns of wood-boring insects, is introduced. From a wood sample, a mixture of noise and action induced substratum vibrations is picked up, amplified, filtered and translated into a sequence of computer-readable numbers which are passed to a microcomputer-based signal-pattern-recognition. If an incomin...
M Pallaske


The treatment of Douglas fir fence posts: specification and compliance using new European standards
1999 - IRG/WP 99-20178
New European standards for the preservative pre-treatment of timber require the results of the treatment process to be specified and subsequently verified by examination of the treated timber for penetration and retention of the preservative. For penetration, the standards are restrictive in that there are only a limited number of options available to the specifier. Thus for ground contact service...
R J Orsler, H Derbyshire


Co-operative research project on L-joint testing. Sampling after 18 months exposure
1984 - IRG/WP 2233
In September 1983, Document No: IRG/WP/2208 was distributed giving guidance on sampling after 8 months exposure (due 1 December 1983 for those L-joints exposed on schedule on 1 April 1983), and including tables on which to record the test results. No major problems have been notified to Princes Risborough Laboratory concerning the sampling method. It is therefore proposed that the next sampling, a...
J K Carey, A F Bravery


Sampling and analysis of NeXgen-treated timber
1998 - IRG/WP 98-20134
Green sawn timber surfaces of the softwood Caribbean pine and the hardwood white cheesewood were treated by dipping, spraying, and precise spiking with the antisapstain product NeXgen. After storing for either two hours or two weeks, the treated surfaces were sampled by one of four alternative protocols, which included two involving a square wad sampling punch (one hit or six hits), one involving ...
M J Kennedy, D E Ferlazzo, T L Woods, M H Freeman


Detection and estimation of Hylotrupes bajulus L. wood damages by ultrasonics
1990 - IRG/WP 2350
To evaluate the validity of the ultrasonic application in the detection and evaluation of wood damages produced by Hylotrupes bajulus L. larvae, some laboratory tests were made with small wood samples. The pulse through transmission method was used. The transit time of ultrasonic pulses in transversal sections, radial and tangential, of the samples was measured. The increment of the transit time o...
G Prieto


Proposals for further co-operative studies on determining toxic values against wood-destroying Basidiomycetes
1985 - IRG/WP 2237
Document IRC/WP/2194 reported the status of the programme of co-operative experiments up to and including December 1982. During discussions at IRG-13 in Turkey members endorsed the decision to complete the programme of tests and conduct repeat tests. At IRG-14 in Brisbane the report was noted but no further action agreed. At IRG-15 in Sweden a number of interested parties in the European/Scandinav...
A F Bravery


Make ready of a detection system for insect attack by acoustical method
1996 - IRG/WP 96-10183
A contract CRAFT of European research allowed to build a detector prototype able to diagnose on site the presence of Hylotrupes bajulus and termites, even during the first stages of infestation when no sign of activity is visible. Based on non destructive control technics, the device picks up the acoustical waves emitted by the insects in the wood fibers. The amplification and the filtering of the...
M Hyvernaud, F Wiest, M-M Serment, M Angulo, O Winkel