IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 75 documents. Displaying 25 entries per page.


Wood-Plastic Composites preservation against fire: Nanofillers as fire retardant alternative
2018 - IRG/WP 18-40843
The purpose of this study is to improve fire resistance of Wood-Plastic Composites (WPCs) by adding inorganic nanofillers. Indeed, the main components of WPC, namely wood and polymer are both flammable materials despite the fact that WPCs are used in the field of construction. The effect of nanofillers on fire retardancy of Wood-High density polyethylene Composites was studied with three nanofille...
D Ben Ammar, A Koubaa, S Migneault, H Bouafif


The development of a suitable fire retardant for Radiata pine and other species
2019 - IRG/WP 19-30744
The use of fire retardant chemicals, with the overarching aim of creating a safer environment is not a new one, however it is generally under-developed and is often afflicted with an image of environmental and health issues and misperceived high costs. There is an ever-increasing need and desire for effective fire retardancy in timbers to inhibit or suppress the combustion process. This is paramou...
B R Derham, M R Fortune


An overview of recent studies involving the thermal modification of hardwood species
2019 - IRG/WP 19-40869
This paper outlines recent activities related to the thermal modification of hardwood species, and particularly to tropical hardwood species. Timber demand is ever increasing, but this is being limited by the necessity to protect virgin forest stands. As such, the majority of supply of popular species is being met from juvenile short rotation stands. The limited age from these stands often plays a...
D Jones, M Gaff, F Kacik


Yellow birch fire-protection using polyelectrolytes complexes
2020 - IRG/WP 20-30755
Fire protection has been a major challenge in wood construction for many years. The demand for high-performance, environmentally friendly treatments respecting the physical and chemical characteristics of the material has been accentuated in recent years. Halogenated fire-retardant (FR) compounds were commonly used from the 70’s for their low-cost and high efficiency. They are able to form radic...
M Soula, F Samyn, S Duquesne, V Landry


Development of Wooden Fireproof Structures for Mid- and High-rise Buildings in Japan
2021 - IRG/WP 21-30757
When constructing a mid-to-high-rise building more than 4 stories in general in Japan, it is necessary to have a fireproof structure stipulated by the Building Standard Law. The performance required as a fireproof structure in Japan is generally stricter than in other countries, and it is required to be structurally sound after a fire even without fire extinguishing activities. In order to satisfy...
D Kamikawa, M Harada, H Matsunaga, R Takase, N Hattori, Keisuke Ando, M Miyabayashi


Effects of Borax and Boric Acid as Fire Retardants on the Resistance of Pterygota macrocarpa Wood to Fire Tests
2022 - IRG/WP 22-30770
The combustible nature of wood as a building material, when exposed to hazards of fire underscores the reason for fire retardant treatments. Pterygota macrocarpa wood is commonly used by builders in Nigeria for roof and other structural applications. Therefore, this study was carried out to assess the effect of Borax and Boric acid on the fire-retardant properties of P. macrocarpa wood. Wood sampl...
J M Owoyemi, O Apogbona, T O Akinwamide


Fire resistance of preservative treated fence posts
1994 - IRG/WP 94-30033
Pine fence posts were pressure treated separately with CCA-C, CCA-wax, CCA-oil and creosote. Treated posts and untreated controls were planted in the ground in a randomised block design, weathered for six months and then subjected to a controlled burning test using two fuel loads. Creosote treatment increased the time that posts were alight whereas CCA treatment had no such effect. However, CCA tr...
P D Evans, P J Beutel, C F Donnelly, R B Cunningham


Oxygen index levels and thermal analysis of wood treated with melamine-formaldehyde-boron combinations
1997 - IRG/WP 97-30135
Melamine formaldehyde (MF) resin was impregnated into scots pine (Pinus sylvestris L.) specimens with aqueous solutions of 5, 10 and 20% concs. Boric acid (BA) and borax (BX) was added to MF resin at the concentration levels of 0.25, 1.00 and 4.70% to each level of resin concs. BA and BX mixture was prepared at the 5:1 (w/w) ratio considering resultant pH of solutions and better fire resistance. U...
M K Yalinkilic, W-Y Su, Z Demirci, E Baysal, M Takahashi, S Ishihara


Absorption of inorganic salts solutions. Retentions of inorganic salts. Fire retardants
1990 - IRG/WP 3625
The study aims evaluated the impregnation capacity using fire retardants on woods with differents densities. At the same time, impregnation with several fire retardant salts were carried out in order to obtain their absortion and retention in wood....
A Garcia, J Navarro


Bibliography: Interactions of wood preservatives with wood, metals, glues, paints and concretes
1983 - IRG/WP 3271
H Becker


Wood preservation in China
1989 - IRG/WP 3546
Huiming Zhou, Zhongwei Jin


Bibliography on the use of boron compounds for the preservation of wood
1973 - IRG/WP 315
This bibliography is based on an earlier literature survey prepared by J. Thornton and Wm. E. Bruce (O.E.C.D. Document No. 27/DAS/CSI/M/91) which was enlarged and revised for a meeting in Paris in October 1968 (Document 27/DAS/CSI/M554) by Professor W. Bavendamm of Reinbek. The latter (1968) document with its 166 references has now been extended and brought up to date. Acknowledgments are due to B...
R Cockcroft, J F Levy


Wood preservation in Japan
1982 - IRG/WP 3218
The report indicates the importance of wood preservation in Japan, which is the world's largest importer. The main hazards of timber are listed, fungi, insects and marine borers. Besides wood preservation fire protection treatments are also important in Japan. Classifications are given of the durability and treatability of the timbers used. In describing the wood preservation industry, th...
S Amemiya, R Cockcroft


A study on insect pests and preservation of fire-damaged timbers in Da Xing An Ling forest region
1991 - IRG/WP 1499
Investigated insect pest of timbers of Da Xing An Ling forest region by means of sampling inspection. Meanwhile we had researched insects pest situation, regularity occurred and biological nature for fire damaged timbers attacked in the log yard. The results showed that the mainly insect species are small black-marmorated longicorn (Monochamus sutor L). We had eagaged in various small tests of tim...
Lu Wenda, Li Jian, Shao Jing Wen, Liu Yixing, Cui Yongzhi


Influence of Acetylation on Fire Resistance of Beech Plywood
2006 - IRG/WP 06-40326
Influence of acetylation on fire resistance was studied in beech plywood. Beech layers were acetylated in a reactor with acetic anhydride at 120ºC for varying durations. Plywoods were made from the acetylated layers and directly exposed to burning flame from their edges for 60s according to ISO 11925-3. Ignition and glowing time were measured in samples. Results were analyzed statistically based ...
B Mohebby, A Talaii, A Karimi , S Kazemi Najafi


Effect of fire retardants (monoammonium phosphate and diammonium phosphate, mixture of monoammonium phosphate and borax and ammonium sulphate) on beech wood with dipping and Lowry methods
2006 - IRG/WP 06-40350
In this study, the possibilities of using four kinds of chemicals as fire retardants with 12% concentration for beechwood (Fagus orientalis Lipsky) was surveyed. Providing testing samples that are related to the measurement of fire resistance properties according to JIS A-1321-1975 standard were evaluated. Wood samples were impregnated with Lowry and dipping methods. In this study, samples impregn...
M Akhtari, D Parsapajouh, M Arefkhani


Effect of fire retardants (monoammonium phosphate and diammonium phosphate, mixture of monoammonium phosphate and borax and ammonium sulphate) on beech wood with dipping and Lowry methods
2006 - IRG/WP 06-40350
In this study, the possibilities of using four kinds of chemicals as fire retardants with 12% concentration for beechwood (Fagus orientalis Lipsky) was surveyed. Providing testing samples that are related to the measurement of fire resistance properties according to JIS A-1321-1975 standard were evaluated. Wood samples were impregnated with Lowry and dipping methods. In this study, samples impregn...
M Akhtari, D Parsapajouh, M Arefkhani


Fire, flame resistance and thermal properties of oil thermally-treated wood
2007 - IRG/WP 07-40361
Oil thermal treatment, first developed by German scientists, is a promising technology for improving the durability and dimensional stability of wood for outdoor above-ground residential uses such as siding and shingles. The present authors’ previous research showed that 220ºC is an optimal treatment temperature, with 2 hours’ treatment producing wood with significantly improved moisture and ...
Jieying Wang, P Cooper


Fire Safety of Wood Floor Assembly: Model and Full-scale Test
2007 - IRG/WP 07-20375
The present paper describes the model for the prediction of fire safety of wood floor assemblies. The model includes heat transfer model for the calculation of the flow of heat in floor assembly and structural model for the analysis of the mechanical performance of wood joists. The floor assemblies considered in this paper are constructed with nominal 2x10 (38x241mm) wood joists lined by Type X ...
H Takeda


Bi-oleothermal treatment of wood at atmospheric pressure: resistance to fungi and insects, resistance to weathering and reaction to fire results
2008 - IRG/WP 08-40418
Bi-oleothermal process is a simple treatment which has been developped by CIRAD in cooperation with FCBA. It allows a deep impregnation of wood with hydrophobic products using cheap facilities. The process includes two steps at atmospheric pressure. The first one is a dipping of wood samples in a hot oil bath (between 110 °C and 200°C) which creates an overpressure inside the wood. The second on...
L Podgorski, I Le Bayon, I Paulmier, J-D Lanvin, V Georges, D Grenier, H Baillères, J-M Méot


Laboratory and field exposures of FRT plywood: Part 1. Physical test data
2008 - IRG/WP 08-40426
Our understanding of the laboratory induced degradation with fire retardant systems is currently limited since we are unable to correlate laboratory steady-state experiments with actual in-service field degradation. Current model studies have generally been limited to isothermal rate studies with selected model FR chemicals. Other factors also play a major role in the degradation of FR-treated woo...
H M Barnes, J E Winandy, C R McIntyre


Improving the Dimensional Stability and Fire Resistance of OSB by Roller-Coating Panels with UV-Curable Finishes
2008 - IRG/WP 08-40434
Oriented strandboard was sanded and roller-coated with UV-cured finishes. The effects of these treatments on the surface roughness, dimensional stability and fire resistance of OSB were assessed. Sanding reduced the average roughness of OSB, but it had a smaller effect on maximum roughness because sanded boards still contained surface voids between some strands. Sanded boards absorbed less than ha...
P D Evans, I Cullis


Thermal behavior of zinc borate-treated wood
2009 - IRG/WP 09-30511
The objective of this study was to investigate the thermal behavior of zinc borate (ZnB)-treated solid wood by thermal analysis (TA). Thermogravimetry (TG) and differential thermogravimetry (DTG) curves obtained from TA showed that ZnB-treated wood specimens had higher char yields and lower maximum thermal decomposition temperature than untreated wood specimens. Reducing thermal decomposition temp...
E Terzi, H Sutcu, S N Kartal


Novel Approaches to the Development and Testing of Anti After-glow Additives for CCA-based Treatments of Poles
2011 - IRG/WP 11-30561
In this paper, a field fire stake testing screen method is described. This method uses stake samples from matched wood sources allowing replicates from different boards to be included. The method is easy to control and can provide quick comparative fire resistance test results. The parameters measured from the tests are percentage weight loss, minimum residual circumference and residual thicknes...
L Jin, P Walcheski, A Preston


Tannin resin-boron for outdoor wood protection and fire retardancy
2011 - IRG/WP 11-30567
Boron in the form of boric acid is well known for its efficacy against wood destroying organisms, as well as for its high leachability from treated wood when in outside exposure. Moreover, due to the European directive 2008/58/EC, boric acid is only authorized at low levels. In order to keep considering boric acid as an interesting active ingredient for wood protection, the issue is now to fix it ...
M-F Thévenon, G Tondi, N Leménager, S Wieland, A Pizzi


Previous Page | Next Page