IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 70 documents. Displaying 25 entries per page.


Japanese Classification of Wooden Building Members for ISO Use Classes according to the Building Code in Japan.
2006 - IRG/WP 06-20337
Because of the international approve of use class system for the biological degradation of wood by ISO/DIS 21887 and ISO/DIS 21892, Japanese committee of ISO/TC165/SC1 asked to the JWPA for classify the wooden commodities by use class of these draft ISO. The JWPA was prepared a draft use class model in Japan. Japanese building code systems are described and Japanese draft use class system is also ...
K Suzuki


Assessing the performance of wood preservatives from biological tests - the European approach
1994 - IRG/WP 94-20040
The impetus for the European Standardisation Committee to undertake the development of a performance standard for characterising the effectiveness of wood preservatives from biological tests, lies in the Construction Products Directive. This is effectively the European Community law which provides the basis for Construction Products to be traded across all member states without technical or regula...
A F Bravery


The natural durability of wood in different use classes
2003 - IRG/WP 03-10457
The natural durability of important European wood species has been tested on 3970 specimen in field trials. The wood was exposed at five test fields in Germany with different climates at each site in European hazard class 4 and 3 (with and without soil contact). Within EHC 3 it was distinguished between tree different expositions (end grain sheltered, unsheltered and with water trap). The test is...
U Augusta, A O Rapp


A field test with anti-sapstain chemicals on sawn pine timber stored and seasoned under different conditions
1984 - IRG/WP 3245
Newly sawn timber of European redwood (Pinus sylvestris L.) was dip treated in four different anti-sapstain chemicals. The protectife effect against sapstain, mould and decay was examined after 10 weeks' and 10 months' storage in open and closed stacks. The results showed that the performance of individual chemicals was different in open and close stacks, although the wood as wel...
D J Dickinson, B Henningsson


A survey of the incidence of decay in copper-chrome-arsenate treated trellis support posts used in horticulture in New Zealand
1984 - IRG/WP 1225
Copper-chrom-arsenate treated softwood posts used as trellis support structures in 5 major horticultural districts of New Zealand were systematically examined for presence of decay. Principal crops on properties examined were grapes and kiwifruit; a minority of properties grew hops, boysenberries, and dwarf apples. Occurrence and severity of decay were variable within specific age classes of posts...
M E Hedley, J A Drysdale


Permanence of permethrin and bifenthrin in framing timbers subjected to hazard class 3 exposure
2005 - IRG/WP 05-30383
End-sealed Pinus radiata specimens measuring 235 x 90 x 35 mm were treated using a modified Lowry schedule with permethrin or bifenthrin in white spirit to Hazard Class 2 (H2) retentions. After conditioning, the specimens were exposed at 45o on north facing racks near Melbourne (Australia). Samples of the specimens were taken before installation, and after three and six months exposure. Analyses o...
A C Hunt, D G Humphrey, R Wearne, L J Cookson


Revised South African standards for wood preservation: Protocols for approval of wood preservatives
1995 - IRG/WP 95-20072
In 1994 the South African timber treatment industry completed its revision of the South African Bureau of Standards (SABS) Code of Practice for the preservative treatment of timber. These revisions were undertaken in parallel with changes to the SABS specifications for preservative treated timber. As a result of shortcomings in the previous wood preservative classification system which was based o...
D Conradie, P Turner, W E Conradie, A D Currie, I S J Burger


Summary report: Symposium "The challenge - Safety and Environment"
1990 - IRG/WP 3590
This summary, presented orally to the audience before the closure of the meeting, received on the principles a wide consensus. It has been written down to be submitted for presentation and discussion at the IRG/21st meeting in ROTORUA, 13-18 may 1990. It cantains summaries from Dr C R Coggins, chairman of Session I (PESTICIDES AND FORMULATIONS); Dr B Hegarty, chairman of Session II (TREATED WOOD);...
Anonymous


Report on the efficacy and performance of the insecticide candidate termiticide in H2 field trials
2004 - IRG/WP 04-10516
This paper explains the field results of phenol pyrazole treated timber against in an above ground mound colonies of Coptotermes acinaciformis (Froggatt). C. acinaciformis (‘termites’) are the major pest of human structures throughout tropical and sub tropical regions, causing billions of dollars in damage to timber-in-service worldwide. The result of this field test have shown that candidate ...
B M Ahmed, P Vinden, J Hann, J R J French


Proceedings from the wood preservation symposium "The Challenge - Safety and Environment" 19-20 February 1990, Cannes, France
1990 - IRG/WP 3600
Contains the List of Participants and the following 29 Documents (IRG/WP/3562-3590): Canadian code of good practices - Recommendations for design and operation of wood preservation facilities. (IRG/WP/3582) Current models used by the European health authorities to evaluate the vililization of active ingredients from treated wood used inside dwellings. (IRG/WP/3565) Creosote and cancer. (IRG/WP/...
Anonymous


Wood preservation requirements in Queensland, Australia
1983 - IRG/WP 3227
In Queensland the preservative treatment and utilization of timber must comply with the Timber Users' Protection Act. Preservative retention levels and penetration patterns must be complied with. Analytical zones are specified for removing samples for chemical analysis of preservative retention. The required retention levels have been expressed as percent weight of oven dry wood weight. T...
L E Leightley, M J Kennedy


Proceedings of the 3rd international wood preservation symposium "The Challenge - Safety and Environment" 6-7 February 1995, Cannes-Mandelieu, France
1995 - IRG/WP 95-50040
Contains the following 35 Documents (IRG/WP 95-50040/1 - IRG/WP 93-50040/35), conclusions (summaries of the sessions chairmen) and some poster abstracts: Le pin: Matériau à contact alimentaire [Pine wood as a material for food contact] (IRG/WP 95-50040/1); The use of a physical field model to study the effects of remedially treated timber on the growth of perennial ryegrass (Lolium perenne) and...
Anonymous


Studies and experiences of occurrence and development of soft rot in salt-treated poles of pine (Pinus sylvestris) installed in Swedish transmission lines in the years 1940-1945
1977 - IRG/WP 277
The present work describes the result of microscopic examinations of some 2,000 borings extracted from 20 to 23-year-old salt-treated poles (Scots pine) from the southern and central parts of Sweden. The purpose was to map out the occurrence of soft rot in Sweden and its influence on the mechanical strength of the poles as well as to contribute to the development of new and more satisfactory metho...
H Friis-Hansen


Categories in wood preservation hazard, risk, and use
1994 - IRG/WP 94-20048
In various countries hazard-, risk-, or use-categories have been established. The different terms seem to be only a sophisticated language problem, but they are rather a basic principle of the philosophy of wood preservation which is going to obtain importance with respect to the low reputation of chemical wood preservatives in an increasing number of countries. Whilst hazard signifies the fact th...
H Willeitner


Methods to determine the efficacy of three water repellent additives in waterborne preservatives
1997 - IRG/WP 97-30142
The paper describes the methods used to determine the efficacy of three different water repellent additives in waterborne preservatives. The wooden samples used are pine (Pinus sylvestris) and spruce (Picea abies) that are treated with 9 different waterborne preservatives in retention for hazard class 3 (above ground commodities). There are two sample sizes exposed, cladding boards (19 x 148 mm) w...
F G Evans, B Nossen, K M Jenssen, L R Wilhelmsen, G Fuglum


Aquatic toxicity research of structural materials
1998 - IRG/WP 98-50114
Continuing from preliminary results reported on the aquatic toxicity of some tropical hardwoods under high hazard conditions, a more comprehensive research study is set-up in order to assess the environmental toxicology of various structural materials in water applications. Hazard class 4 preservative treated wood is tested for its toxic response on a battery of aquatic test organisms, next to con...
G M F Van Eetvelde, S De Geyter, P Marchal, M Stevens


A 53-year old field trial to evaluate the performance of a range of chemical treatments on eucalypt poles
1989 - IRG/WP 3526
Hardwood pole stubs of Eucalyptus maculata, Eucalyptus pilularis, Eucalyptus saligna and Eucalyptus paniculata were examined for termite attack and fungal decay after 53 years in ground contact. The trial compared eight different chemical treatments with untreated pole stubs of the four species investigated. Untreated Eucalyptus paniculata, a Class I durability species, performed particularly well...
R S Johnstone, R A Eaton


The risk assessment process. Point of view of a biocide manufacturer [Évaluation du risque. Point de vue d'un fabricant de biocide]
1990 - IRG/WP 3568
Risk assessment is an inherent part of our everyday lives. The risk assessment equation combines Hazards and Exposure. For the Wood Preservation Industry, the hazards may be characterised by the toxicity a the ecotoxicity of chemicals and the exposure by the identification of exposed people, of the exposure routes and exposure frequency. To quantify the exposure, good co-operation is required betw...
D Baur


The use of organic wood preservatives in ground contact and the suitability of laboratory test procedures to determine their efficacy
1999 - IRG/WP 99-20175
Organic fungicides, such as propiconazole, have proven to be highly effective when used as a co-biocide in recently developed wood preservative formulations. They have however been ineffective when used as a stand alone preservative, particularly when used in ground contact (European Hazard class 4). Previous research, using the test methods of ENV 807 (1993), provided conflicting evidence regardi...
I J Herring, D J Dickinson


The critical timing of inspections for field testing of natural durability
1994 - IRG/WP 94-20018
An overestimation of performance will almost always result if the condition of a specimen is considered to be attained at the precise time that an inspection is carried out. The time at which the condition is actually attained, referred to in this document as the "Condition time", is best considered to be halfway between two successive inspections. The requirement to obtain data that is relevant t...
J D Thornton


The natural durability of wood in different use classes - PART II
2006 - IRG/WP 06-10598
The natural durability of important European wood species has been tested on 3970 speci¬mens in field trials. The wood was exposed at five test sites in Germany with different climates, at each site in European use class 4 and 3 (with and without soil contact). Within European use class 3 three different expositions were tested: vertical with sheltered end grain, vertical unsheltered and horizont...
A O Rapp, U Augusta, K Brandt


Information on a project about the conditions of admissibility of wood-protecting agents in connection with environmental protection in Poland
1974 - IRG/WP 57
Wood-protecting agents are compounds acting toxically on fungi and insects. If handled improperly or carelessly, they may exert an action harmful to health and safety of men. This action is concerning: a) workers employed at the production of wood-protecting agents; b) workers employed at the impregnation, or at the transport and handling of impregnated wood; c) inhabitants of buildings with impre...
J Wazny


Is Field Test Data from 20 x 20mm Stakes Reliable? Effects of Decay Hazard, Decay Type and Preservative Depletion Hazard
2006 - IRG/WP 06-20327
Effects of decay hazard, decay type and preservative depletion hazard on the performance of variously preservative treated 20 x 20 x 500 mm Radiata pine and Fagus sylvatica test stakes across 13 field test sites in New Zealand and Queensland Australia were determined. Radiata pine treated with an ammoniacal copper quaternary preservative (ACQ) (1.56% m/m a.i.) and copper chrome arsenate (CCA) (...
R Wakeling


A New Decay Hazard Map for North America Using the Scheffer Index
2008 - IRG/WP 08-10672
Wood decay experts in the USA and Canada use the Scheffer Index for above-ground wood decay potential to decide among design and treatment options to ensure the durability of wood construction. This paper provides an updated North American decay hazard map and includes data on Central America. Index values calculated from recent climate data are higher than published values due to directional or c...
P I Morris, J Wang


Decay Hazard Classifications in China for Exterior Above-Ground Wood
2007 - IRG/WP 07-20357
A decay hazard map for exterior above-ground wood structures is presented based on Scheffer’s Climate Index, with the major purpose of promoting awareness for proper protection of wood structures in different locations in China. A very large area in the South, including southern Yunnan, most of Sichuan Province and Chongqing, and part of Hunan, Hubei, Anhui, Jiangxi, and Zhejiang, as well as all...
J Wang, X Wu, M Jiang, P I Morris


Previous Page | Next Page