Analysis on dynamics of basidiomycetes in decayed wood by a method using non-specific amplification of DNA
2009 - IRG/WP 09-20426
A combination of non-specific amplification of DNA by Phi29 DNA polymerase and specific amplification of the internal transcribed spacer (ITS) region of ribosomal DNA (rDNA) by polymerase chain reaction (PCR) was applied to elucidate the ratio of basidiomycete species inhabiting decayed wood from an outdoor bench. After more than 8 hours incubation with Phi29 DNA polymerase, concentration of DNA ...
T Wada, K Igarashi, M Samejima


rDNA-ITS sequence of Serpula lacrymans and other important indoor rot fungi and taxon-specific priming PCR for their detection
1999 - IRG/WP 99-10298
Taxon-specific priming polymerase chain reaction (TSPP) is a powerful molecular tool for fungal diagnosis. For its application to indoor rot fungi, the internal transcribed spacer (ITS) of the ribosomal DNA (rDNA) of the main fungal species causing wood rot in European buildings was amplified with the polymerase chain reaction (PCR). The ITS region was sequenced. The complete sequences are present...
O Schmidt, U Moreth


Detection of the dry rot fungus Serpula lacrymans by amplified ribosomal DNA restriction analysis
1998 - IRG/WP 98-10245
Isolates of the dry rot fungus Serpula lacrymans and the wild merulius S. himantioides were investigated by amplified ribosomal DNA restriction analyses (ARDRA) of the internal transcribed spacers (ITS). The technique uses the polymerase chain reaction (PCR) to amplify the variable region of the ITS between the conserved 18S and 28S genes of the nuclear ribosomal DNA (rDNA). The ITS region of all isolates of Serpula lacrymans and S. himantioides was successfully amplified. The length of the amplified product was about 630 bp. Subsequent double digest of the ITS with the restriction endonucleases Haelli and Taql separated the closely related fungi by species-specific fragments. Thus, ARDRA-ITS proved to be suited for the detection of the dry rot fungus.
O Schmidt, U Moreth


Low temperature drying conditions of Pinus radiata wood for avoiding internal stain
1989 - IRG/WP 3507
It has been observed that, if in little sawmills, timber is dried with a low temperature schedule, it arrives at destination with internal sapstain besides of superficial mould. In this study, the lowest drying temperature at which wood should be exposed for sterilization, which results to be 52°C, is searched. It is not possible to avoid entrainment of pentachlorophenol, even though a waiting pe...
M C Rose


Cu, Cr and As distribution in soils adjacent to CCA treated utility poles in Eastern Black Sea Region of Turkey
2004 - IRG/WP 04-50214
In this study, the main objective was to asses the distribution of Cu, Cr, and As in soils adjacent to CCA treated utility poles in Eastern Blacksea Region of Turkey (Trabzon, Rize and Artvin ) and determine the influence of soil composition. Surface (0-5cm), subsurface soil samples (30-40cm) were collected near CCA-treated utility poles and control soil samples away from CCA-treated utility pole...
E D Gezer, Ü C Yildiz, A Temiz, S Yildiz, E Dizman


Termite standards questionnaire survey. Second Report
1989 - IRG/WP 1395
Information contained in replies received from IRG members responding to the survey continue to be summarised. Again, highlighted in this second report are the major termite species in the various zoogeographical regions, their damage ranking to timber-in-service, the chemicals used in control methods, and the status of the termite standards in the respondent countries....
J R J French, J P La Fage


The internal-external diffusion process: Table salt treated poles
2005 - IRG/WP 05-50224-25
This new technique of preservation of wooden poles consists of keeping preservative in stock, in a reservoir drilled inside the pole, in its whole length. This permits the use of non toxic, common products such as table salt, grease, etc, in the preservation of utility poles, building columns, or the like. Some major obstacles to a good implementation of a good preservation with the classical pr...
L Nitunga


The effect of storage or simulated internal use on the durability of wood based panels to decay fungi
1997 - IRG/WP 97-20106
Wood based panels such as particleboard and medium density fibreboard are experiencing a steady increase in use, in areas from structural to decorative applications. Understanding the "natural" durability of these panel products against basidiomycete fungal decay is therefore of great importance. Various methods have been proposed or are under development to test the durability/susceptibility of v...
S F Curling, R J Murphy, J K Carey


Wood-destroying insects found in the Eastern Black Sea sub-region of Turkey
1982 - IRG/WP 1153
The Eastern Black Sea subregion has important forest resources. The settlement areas are scattered at the countryside. That's why a good deal of wood and timber is used in the construction of buildings without sufficient protective measures in the rural areas. In the forests and rural buildings 52 wood-destroying insect species have been specified 35 of which are new in this subregion and...
O A Sekendiz


Examen chimique du traitement de poteaux effectué à St-Michel s/Meurthe
1974 - IRG/WP 337
J Guillemain-Thévenot, C Jacquiot


Methods of assessing decay in poles in service with the Pilodyn wood tester
1978 - IRG/WP 2107 A
H Friis-Hansen


Wood-destroying Rhinotermitidae (Isoptera) in the oriental region
1984 - IRG/WP 1236
Species of the family Rhinotermitidae are important wood-destroying termites. From the Oriental zoogeographical region, 85 species of the family are reported of which some are wide spread and cause extensive damage to wood, wooden articles and other cellulosic products. The distribution, biology, ecology and pest status of the important wood-destroying species, in the Oriental region, are given in...
O B Chhotani


The leachability and specificity of the biological protection of timber using Scytalidium sp. and Trichoderma spp
1986 - IRG/WP 1302
The results of field experiments, using biological control against internal decay of creosoted poles, are briefly reviewed and the evidence concerning the leachability of the antibiotics produced by these species is presented. A pure culture miniblock decay test on biological control treated pine sapwood is described and the results compared to previously published data. The protection against Len...
P I Morris, N A Summers, D J Dickinson


Ancillary properties of vapor boron-treated composites
2001 - IRG/WP 01-40210
This paper discusses the water absorption, thickness swelling, and internal bond strength of North American composites treated using a vapor boron treatment process. For oriented strandboard, high boron loadings led to lower internal bond strength and lower thickness swelling. Water absorption results were variable but no deleterious effect of treatment was noted. For medium density fiberboard, th...
W A Jones, H M Barnes, R J Murphy


Survey of maintenance management of a residence
2001 - IRG/WP 01-10405
The following points were clarified from the responses to the questionnaire. Termite damage was most common in the bathroom, washroom, and entrance, in that order. Termite damage was most commonly found beneath floors, followed by floor surfaces, and inside walls, in that order. Damage in framing was minimal. Damage in all structural components was most common in the Kyushu region, with the most s...
Y Yamaguchi, M Azuma, Y Hikita, K Nishimoto


Termite standards questionnaire survey - First Report
1988 - IRG/WP 1354
Information contained in replies received from IRG members responding to the termite standards questionnaire survey are summarised. Highlighted in the results of this first report are the major termite species in the various zoogeographical regions, their damage ranking to timber-in-service, the chemicals used in control methods, and the status of termite standards in the respondent countries....
J R J French, J P La Fage


Performance if internal remedial treatments to arrest fungal attack in poles and large timbers
2018 - IRG/WP 18-40834
Internal remedial treatments have been used to arrest internal fungal attack in utility poles and other large timbers. Water diffusible systems and volatile fumigants have both been used for this purpose. While both work, it is important to understand the performance attributes of each system. This paper reviews the literature on both systems and makes recommendations for future research....
J J Morrell


Summarized comparison of four techniques for detecting defects in poles
1979 - IRG/WP 2126
Since our discussions in open session of Working Group II at Peebles, a number of workers in Australia have collaborated in comparing the efficacy of X-ray, sonic testing, or resistivity measurements for detecting internal defects in poles. The purpose of this circular is to draw to your attention some of the results, in summary form. No attempt has been made to compare techniques. More detailed a...
H Greaves


A Preliminary Report on the Properties of Engineered Wood Composite Panels Treated with Copper Naphthenate
2005 - IRG/WP 05-40294
This paper reports on our preliminary investigation of the properties of randomly oriented strandboard which had waterborne or powdered copper naphthenate (CuN) incorporated into the board during manufacture. When compared to zinc borate-treated controls (ZnB), the mechanical properties of strandboard (MOR, MOE, work-to-maximum load, internal bond strength) were not adversely affected by treatmen...
J W Kirkpatrick, H M Barnes


Decay Resistance and Bonding Properties of Structural Flakeboard
2002 - IRG/WP 02-40233
Experimental structural flakeboard panels consisting of differing furnishes and resins were produced and tested for internal bond, linear expansion, thickness swell, and decay resistance. One group of panels was produced with recycled CCA-treated wood as the furnish and commercial phenol formaldehyde (PF) resin as the binder. Other groups of panels were produced with either mixed hardwoods or so...
T F Shupe, Chung-Yun Hse


Internal pressure monitoring during the treatment of Pinus radiata (D. Don)
1995 - IRG/WP 95-40049
The use of micro-transducers to monitor the internal pressure of wood during treatment is investigated. The rates of pressure transfer in radiata pine sapwood and heartwood are compared during Bethell treatment with copper chrome and arsenic preservative. The effect of pre-conditioning treatments are also evaluated using micro-transducer monitoring. It is anticipated that knowledge of the changes ...
P R S Cobham, P Vinden


A novel device for detecting internal defects in wooden poles
1989 - IRG/WP 2329
The diagnosis of internal defects caused by termites and decay in hardwood transmission poles has been investigated using a novel Automatic Feed Drill (AFD) pole testing device. Internal defects were recognised by changes in drill feed-rate as the automatic air-driven drill traversed its 100 mm working stroke. The instrument is portable, simple to operate and recognises defects instantaneously. Te...
R A Eaton, R S Johnstone


The use of the Shigometer® and Pilodyn® as non-destructive test methods for detecting decay in CCA treated eucalypt poles
1981 - IRG/WP 2153
The groundline condition of sixty C.C.A. treated eucalypt poles comprising six different species was examined using the Pilodyn® and Shigometer®. Although sensitive to the presence of soft-rot decay, the Shigometer® would seem to offer little practical advantage in the eucalypt soft-rot decay situation, since a comparable visual examination could reveal the presence and extent of decay. Initial...
L E Leightley


Evaluation of the pulsed-current resistance meter (Shigometer®) for determination of the internal condition of utility poles
1979 - IRG/WP 2128
A number of Telecom poles, which had been removed from service to be replaced by a radio link, were inspected using an electrical resistance meter (Shigometer®). These poles were creosoted, non-durable Victorian species in service in New South Wales. Six of these poles, chosen to represent various internal conditions typical of the range of the population tested, are discussed here. Data, from tr...
J D Thornton, W G Seaman, M McKiterick


Contribution to the knowledge of wood-rotting fungi in Brazil. Part 1: Occurrence and distribution of fungi on different substrates from the Manaus region, Amazonas State
1995 - IRG/WP 95-10096
A total of 945 spezimens of fungi were studied with regard to their distribution on ditterent substrates, abundances and economic importance. The samples came from the collection ot the Wood Pathology Laboratory of CPPF/INPA in Manaus, Brazil. Altogether, 163 spezies and 87 genera were identified. The following genera Trametes, Auricularia, Panus, Rigidoporus and Hymenochaete were represently by m...
M Aparecida de Jesus