Control of termite attack using a trapping method and acoustic emission (AE) monitoring a case study at an electric power plant

IRG/WP 97-10224

Y Fujii, Y Imamura, E Iwatsubo, S Yamamoto

To prevent subterranean termites (Coptotermes formosanus Shiraki and Reticulitermes speratus Kolbe) from invading the buildings of an electric power plant and to control their attack, artificial traps were buried around the buildings. The attack of the termites in and around the traps was monitored by detecting acoustic emissions (AE) generated by the feeding behavior of the workers. The cylindrical artificial traps were 600 mm long and 300 mm in diameter, and consisted of pieces of Japanese red pine surrounded by slender polystyrene foam sticks. Termite inhabitation was observed in eight of the ten traps set, and particularly high levels were found in three traps. The traps were renewed every one or two months. The amount of termites inhabiting the traps decreased drastically after the first renewal, but varied only slightly over the following two and a half years. The amount of termites in the traps increased when the traps were not renewed. Termite activity was significantly restricted by installing artificial traps and no additional serious attacks were found in or around the buildings during the study period. AEs generated by feeding activities were monitored by piezoelectric AE sensors attached to the wooden sticks in the traps or to wooden bait stakes near the trap. The rate of AE events varied according to feeding activity which was associated with the number of termites in the trap and the temperature.


Keywords: ARTIFICIAL TRAP; AE MONITORING; CONTROL OF TERMITE ACTIVITY

Conference: 97-05-25/30 Whistler, British Columbia, Canada


Download document (698 kb)
free for the members of IRG. Available if purchased.

Purchase this document