Drying Rates and Mold Growth on Various Building Materials under Different Environmental Conditions
2010 - IRG/WP 10-20454
Mold growth on building materials is a major problem for homeowners. The most suitable method to control mold growth on building materials is to utilize design features, construction tools and practices that prevent moisture accumulation, and keep the wood as dry as…
Dian-Qing Yang


Towards designing eco-friendly buildings with in-built termite protection
2010 - IRG/WP 10-50273
…IRG members and IRG as an institution, which include the building, chemical, academic, and pest control industries dealing with the challenge of global warming in sustaining their businesses? Can we advise these industries to make choices to minimise the impact of global warming and minimise their carbon…
J R J French, B M Ahmed Shiday, B Maggiolo, D Maggiolo


The amazing wooden churches from Northern Romania - learning from the past, restoring for the future, preserving the present valuable heritage of forgotten wood building tradition
2009 - IRG/WP 09-10683
…were erected in a way in which even today some of these building are still standing and integrate nicely with the landscape. As always good time and bad time are cycles in the human history and time have its impact on the any wooden construction. Restoring and preserving these unique wooden churches from…
R Craciun, R Möller


Building with termites: The challenge of biomimetic design for carbon neutral buildings.
2009 - IRG/WP 09-20405
…What termites can tell us about realizing the living building”, Turner and Soar (2008) opens up a new era in how we think of human habitations, not only on earth, but maybe on other planets, and using the termite model as the corner stone of innovative engineering. We know that termites are masters of…
J R J French, B M Ahmed (Shiday)


Wood decay fungi from New Zealand leaky buildings – PCR identification (Part 2) and aerial spore trapping
2008 - IRG/WP 08-10649
…species of decay fungi caused decay in New Zealand leaky buildings. Use of molecular biology methodology, polymerase chain reaction (PCR), and subsequent DNA sequencing, as well as classical mycological techniques based on morphology, has enabled identification of decay fungi and has provided insight into their…
D Stahlhut, R L Farrell, R Wakeling, M Hedley


Water Absorption of Various Building Materials and Mold Growth
2008 - IRG/WP 08-10657
…for house owners, as it often occurs on the surface of building materials in damp houses. The principal method to control mold growth on building materials is to prevent water penetration into the materials. A study was recently conducted to determine water absorption rates of different wood species and panel…
Dian-Qing Yang


Japanese Classification of Wooden Building Members for ISO Use Classes according to the Building Code in Japan.
2006 - IRG/WP 06-20337
…was prepared a draft use class model in Japan. Japanese building code systems are described and Japanese draft use class system is also described.
K Suzuki


A review of environmental emissions from building and construction materials in comparison with preserved wood
2005 - IRG/WP 05-50224-11
…from materials which are used in the construction of buildings (e.g. Concrete, Asphalt, Galvanised Steel), in comparison with preserved wood, and a review of the approaches taken by the construction sector in assessing the risk from environmental emissions, in comparison with the approaches taken by the wood…
E F Baines


Development on Damage Functions of Wood Decay for Building Envelope Design
2005 - IRG/WP 05-10556
For the hygrothermal analyses of building envelope systems for insulation design, we tried a natural decay test of wetted wood specimens without any inoculation of fungi. Three principal experimental types: under steady-state conditions (Experiment A), at a cyclic water dripping under…
H Suzuki, Y Kitadani, K Suzuki, A Iwamae, H Nagai


Risk reduction from curative treatments, restoration and maintenance of building and individual housing - simple precautions that make the difference
2005 - IRG/WP 05-50224-15
…of result with procedures adapted to the site of the building and its own exposure, another route of improvement. As works in this field are often non typical, there is still room for the optimisation of individual options, based on experience, to locate the necessary dose and performance at the right place.…
G Ozanne


Evaluation of decay fungi in Norwegian buildings
2005 - IRG/WP 05-10562
…2001 - 20 March 2003) Mycoteam had 3161 consultations in buildings in southern Norway, 1428 revealing damage from decay fungi. One consultation often revealed several occurrences of fungi, and the total number of occurrences of decay fungi was 3434. Thirty-five different species/genera/groups of decay fungi were…
G Alfredsen, H Solheim, K Mohn Jenssen


Long-term preservation technology for a large-scale timber structure building in Japan
2001 - IRG/WP 01-40203
…which are inscribed on the World Heritage List. These old buildings are indicative of excellent timber construction technology having existed in ancient Japan, though it is thought that such technology has not been handed down. This paper introduces one of large-scale wood buildings built in recent years that…
Y Iimura


Experimental real building evaluation of termite attack - Effect of the space between the mat foundation and the thermal insulation
2000 - IRG/WP 00-10374
…barrier system against termites were evaluate by the real building scale test method.
K Suzuki, K Hagio, Y Tanaka


Wood durability in the light of recent trends and research on the durability of building materials and components
2000 - IRG/WP 00-20195
Building-related research of today demonstrates a clear shift in focus from the design and production phases to usage and to the entire life time. A consequence is that the performance criteria of materials, components and of the entire building must be…
K Ödeen


The dry rot fungus (Serpula lacrymans) in nature and its history of introduction into buildings
1999 - IRG/WP 99-10300
…(Wulf.: Fr.)Schroet.) has exclusively been found in buildings. That is why it is called the True dry rot fungus. The origin of the fungus has always been a mystery, but a wild ancestor must have occured. In the literature there is some information about finds of Serpula lacrymans in nature, however it is…
J Bech-Andersen, S A Elborne


Results on termite resistance of building materials against Coptotermes formosanus by choice test
1998 - IRG/WP 98-10275
Various building materials, included wood species, wooden board materials, thermal insulation materials and fire-protection materials, were tested for grading of termite resistance against Coptotermes formosanus. The dimension of most specimens were 2x2x2cm3. Ten…
K Suzuki, K Hagio


A novel chemical barrier system, KORDON® TMB, for the protection of buildings against subterranean termites using a synthetic matrix as carrier for the chemical
1998 - IRG/WP 98-10264
…LDPE. Installation of the barrier follows existing building practice of setting down and sealing the vapour barrier, as required, during site preparation for building. Results of the evaluation of component materials and key features of the Kordon TMB system, which has been ongoing for the past eight years,…
M Lenz, P Morrow, S Runko


An overview of termite control in buildings in Kenya
1997 - IRG/WP 97-10242
…timber and are responsible for considerable damage in the building sector in sub-Saharan Africa. A general diagnostic survey of damaging termite species in agriculture, forestry and buildings was carried out for the first time in Kenya (1991-1992). Termite species implicated in damage to wooden materials and…
G R S Ochiel, W Gitonga, L Toft


Termite physical barriers: update on retrofitting Granitgard™ around 'mock-up' buildings after five years
1997 - IRG/WP 97-10226
…when retrofitted around 'mock-up' buildings. The field site is located at Walpeup in the semi-arid mallee region of north-west Victoria (360 km from Melbourne), and there are eight common indigenous subterranean termite species at the site. This paper describes the results of the field…
J R J French, B M Ahmed


How predictive are laboratory experiments for assessing the effects of chitin synthesis inhibitors (CSI) on field colonies of terrnites? - A comparison of laboratory and field data from Australian mound-building species of termit
1996 - IRG/WP 96-10143
A singular advantage of using mound building species of termite is their directly accessible nest. This allows evaluation of control methods by accurate assessment of the effects at the colony level. The mound building species Coptotermes acinaciformis (Froggatt) and Nasutitermes exitiosus…
M Lenz, P V Gleeson, L R Miller, H M Abbey


Granitgard used as a partial and perimeter barrier in the protection of buildings against subterranean termites
1995 - IRG/WP 95-10114
…of National Accreditation issued by the Australian Building Codes Board, and is included in Australian Standards. After several years in developing the specifications and installation techniques for Granitgard, it may be used to protect almost all footing designs. Granitgard can be simply placed around slab…
D M Ewart, J R J French


New methods for nondestructive inspection of timber in buildings
1995 - IRG/WP 95-20070
In these years older buildings are renewed in most European countries on a large scale, and new techniques are needed for both inspection and eradication of fungal attacks. Heat treatment as a means of eradicating the dry rot fungus has been used in Denmark during the last…
B Madsen, O V Frederiksen


Experiences from a Danish large scale test by means of a new method of treatment by attack of true dry rot fungus (Serpula lacrymans) in buildings
1994 - IRG/WP 94-10064
…large scale test comprising repair of more than 150 Danish buildings over a period of approximate 5 years. The method being both gentle to the building and presenting savings of at least 70% compared with the traditionally known repairing methods is based on thorough recording of the extent of attack and examination…
O Munck, H Sundberg


Termite physical barriers: Current status of retrofitting Granitgard around 'mock-up' buildings
1994 - IRG/WP 94-10057
…when retrofitted around 'mock-up' buildings. The field station is located at Walpeup in the semi-arid mallee region of northern Victoria (360 km north of Melbourne), and there are several indigenous subterranean termite species at the site. After 20 months, no foraging by Coptotermes species…
J R J French, B M Ahmed


The status of Anobium punctatum and Hylotrupes bajulus in buildings in the United Kingdom
1993 - IRG/WP 93-10039
…with remedial treatment companies, local authorities and building societies to establish the incidence and status of these insects with respect to geographical location, age and type of building. The results update those from previous BRE surveys published in 1965 and 1973. Results for Anobium punctatum show a…
R W Berry, R G Lea, D Higham