IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 18 documents.


Use of freeze disinfection for the control of the common furniture beetle Anobium punctatum
1992 - IRG/WP 92-1528
The common furniture beetle Anobium punctatum is an extremely widespread pest of wooden objects in Danish museums. In order to develop non-chemical methods of controlling the pests, experiments were conducted to elucidate the lower lethal temperature of Anobium punctatum. The egg stage was used for the experiments as it is considered the most temperature resistant stage. Groups of Anobium punctatu...
L Stengård Hansen


Eradication of wood decay fungi by means of radio frequency
1998 - IRG/WP 98-10292
High frequency electromagnetic fields i.e. radio frequency (RF) are used in wood industry for heating, gluing and bending of wood and are also appropriate for eradicating of wood decay fungi and insects. We investigated the effects of RF exposure on wood samples which were in vitro infected by Coniophora puteana, Gloeophyllum trabeum and Lentinus lepideus. For each fungus, the lethal temperature a...
F Pohleven, J Resnik, A Kobe


The restricted distribution of Serpula lacrymans in Australian buildings
1989 - IRG/WP 1382
Temperature data has been gathered over a number of years, not only for flooring regions of various buildings in Melbourne, but also within roof spaces and external to the buildings. Findings are discussed in relation to the distribution of Serpula lacrymans within Australia, its restriction to certain types of building construction and its restriction to flooring regions. The subfloor spaces of b...
J D Thornton


Supercooling points of Anobium punctatum, the common furniture beetle
1995 - IRG/WP 95-10120
Ice formation within the body of larvae of the common furniture beetle Anobium punctatum causes death of the larvae. Freezing can therefore be used as a means of eradication of the larvae in infested wood. To optimize the freezing process, knowledge of the temperatures sufficient to kill the larvae is essential. Ice formation is initiated by temperatures equaling the so-called supercooling point, ...
T E Hallas, K Bohn Hansen


The use of zirconium as an inert fixative for borates in preservation
2001 - IRG/WP 01-30256
Stand-alone borates have been used in internal protected situations as wood preservatives for about 60 years. They have not been deemed acceptable for external situations because of their leaching characteristics. Work carried out to reduce the leachability of borates has been reviewed briefly here, and a specific fixation agent based on zirconium has been tested in standard leaching and decay tes...
J D Lloyd, J L Fogel, A Vizel


Laboratory and field evaluation of Plasmite Reticulation System using bifenthrin as a chemical barrier within wall cavities against subterranean termites.
2005 - IRG/WP 05-20307
Laboratory and field bioassays undertaken to demonstrate Plasmite Reticulation system effectively delivers the termiticide (bifenthrin) within a simulated wall cavity at the required concentration. The chemical assay indicated that the amount of bifenthrin sampled at 5, 10, 15, 20, and 25m along the simulated reticulation system tested (30m) exceeded the manufacturer’s minimum recommendation of ...
J R J French, B M Ahmed, J Thorpe, A Anderson


Quality control of microwave treatment of timber after dry rot attack
2001 - IRG/WP 01-40205
In Denmark microwave treatment of timber has been used during the last 15 years for eradication of dry rot (Serpula lacrymans). About 1500 microwave treatments have been employed in coorporation with Hussvamp Laboratoriet. Previously all the infected timber was removed plus an extra metre as a safety zone. This meant that all casting boards and plaster had to be removed as well and joists replaced...
J Bech-Andersen, J Andreasson, S A Elborne


Methods for testing fumigant efficacies against termites
1986 - IRG/WP 1297
Methodologies for testing fumigants against termites are reviewed and factors needed to be taken under consideration for standardization listed. Toxicity should be defined by both direct exposure to the gas and under more practical "barrier" conditions which include test enclosures simulating abiotic surroundings of the termites, i.e. wood, nest material, etc. To observe latent effects, mortality ...
N-Y Su, R H Scheffrahn


Investigation of microwave as a means of eradicating dry rot attack in buildings
1992 - IRG/WP 92-1545
A microwave-apparatus developed for treatment of building-structures infested by dry rot was tested in the laboratory. The test-conditions simulated treatment of either infested timber or infested brickwork. Sawdust samples, both wet and dry, infested by viable mycelium of Serpula lacrymans were packed in glass-tubes. The tubes were then placed in the middle of either 20 cm thick wooden beams or 3...
C Kjerulf-Jensen, A P Koch


Report on the burning of wood treated with wood preservatives containing copper, chromium and arsenic
1976 - IRG/WP 379
Mixtures of copper, chromium and arsenic salts are used extensively in the UK to preserve timber. This report is concerned with the fate of these metals when timber treated with these salts is burned. A large percentage of the arsenic present in the timber is shown to be volatilised during combustion and the potential environmental implications of this are assessed by comparison with the release o...
A J Dobbs, C Grant


The residual effects of remedial timber treatments on bats
1986 - IRG/WP 1281
By means of controlled laboratory experiments it was established that timber treatment fluids containing g-HCH and pentachlorophenol (PCP) and used according to manufacturers recommendations rapidly cause the death of pipistrelle bats roosting in contact with timber treated between six weeks and 14 months previously. The chemicals responsible are presumably ingested when the bats groom their fur a...
P A Racey, S M Swift


Risk of pulmonary damage as a result of an evaporation of ca. 50 ppb = 42 mg HF, evaporated from wood treated by difluorides
1987 - IRG/WP 3401
In this review of the literature the effects of fluorides and fluorine on man are described, especially the low level effects of inhaled HF on human beings. The term "fluoride" is used as a general term everywhere, where exact differentiation between ionic and moluecular forms or between gaseous and particulate forms is uncertain or unnecessary. The term covers all combined forms of the element, r...
H F M Nijman


Lethal temperature for some wood-destroying fungi with respect to eradication by heat treatment
1984 - IRG/WP 1229
The lethal heat dosis as a function of temperature and time of exposure has been tested for mycelium and for wood infested by three strains of Serpula lacrymans and by Coniophora puteana, Poria monticola, Paxillus panuoides, Gloeophyllum trabeum and Gloeophyllum sepiarium. Even for Serpula lacrymans, which is well known for its sensivity to heat treatment, 30 min at 55°C were necessary to kill th...
M Miric, H Willeitner


The loss of insecticidal action from synthetic pyrethroid-treated wood samples: The effect of high temperatures and relative humidities
1992 - IRG/WP 92-1569
This paper describes the results from bioassays using Hylotrupes bajulus, and chemical analyses, of pyrethroid-treated wood samples following storage for up to 3 years. A range of four storage environments was used consisting of combinations of two temperatures (20°C and 40°C) and two relative humidities (60% and 90%). It is concluded from the chemical analyses that, although losses at room temp...
R W Berry, S J Read


Determination of the lethal dose of fipronil for workers of Coptotermes formosanus (Isoptera: Rhinotermitidae
2007 - IRG/WP 07-10616
This document is a combination of two articles previously submitted to the journal, Sociobiology. Lethal dose of fipronil was determined in two experiments: topical application and contact with treated sandy loam. In the topical application the toxicity of fipronil was evaluated against workers of a laboratory colony of Coptotermes formosanus Shiraki. Fipronil was applied by the microsyringe to t...
K Tsunoda, R Yamaoka


Tensile stress relaxation of wood impregnated in different ACQ formulations at various temperatures
2009 - IRG/WP 09-40456
The reactions between ammoniacal copper quat (ACQ) constituents and wood components were investigated by tensile stress relaxation approach. Small wood samples were stressed and impregnated in ACQ solutions with different formulation including the ethanolamine (MEA) to copper molar ratio, copper (as copper oxide) to quat (as DDAC) weight basis, treatment temperature and also the solution concentra...
Lili Yu, Jinzhen Cao


The effect of UV irradiation on some technological properties of different polyurethane varnishes coated plywood panels from veneers dried at different temperatures
2014 - IRG/WP 14-40661
In this study, the effect of UV irradiation on some technological properties of three different polyurethane varnishes coated plywood panels produced from Scots pine (Pinus sylvestris L.) and Maritime pine (Pinus pinaster L.) veneers manuactured and dried at different temperatures was studied. Accordingly, 32°C log peeling temperature and three different veneer drying temperatures (110, 140 and ...
Ö Özgenç, C Demirkir, Ü C Yildiz, G Çolakoğlu


Susceptibility of wood substrates to Aurebasidium pullulans at different temperatures
2016 - IRG/WP 16-10863
There is an increasing awareness of how the aesthetical performance of wood exposed outdoors changes over time and especially in the first few years after installation. Mould and blue stain fungi are biological agents that contribute to the weather grey colour on a wooden façade, and the blue stain fungi Aureobasidium pullulans is commonly identified as colonizer on coated and uncoated wood expos...
L Ross Gobakken, G Alfredsen