A standardised procedure for the treatment of timber with test chemicals
1986 - IRG/WP 2257
A procedure is described which allows the standardisation of sample handling and data manipulation during trials invastigating the treatability of timber with test chemicals. The use of computer software allows the data to be handled efficiently....
J Norton, A Zosars, L E Leightley


Steam conditioning of partially dried radiata and Corsican pine roundwood
1988 - IRG/WP 3499
The effect of partial air drying prior to steam conditioning and its effect on subsequent preservative treatment by the Bethell treatment process was investigated. A high standard of preservative treatment was obtained in both radiata and Corsican pine, irrespective of whether a period of partial drying was imposed before or after steam conditioning....
P Vinden, D R Page, K Nasheri


Performance of surface-treated hardwoods and softwoods out of ground contact
1990 - IRG/WP 3592
A number of fungicides were tested as brush treatments for protection of southern pine, Douglas-fir, maple, and red oak against decay above ground. Cross-brace and L-joint test units were treated just before assembly and exposed from 3-10 years. Untreated Douglas-fir cross-brace units were not decayed at either the Mississippi or Madison, WI, site. Untreated red oak cross-brace units were not deca...
T L Highley


Long-term performance of a "wax" type additive for use with water-borne pressure preservative treatments
2000 - IRG/WP 00-40159
Field performance results are updated for matched CCA treated decking boards with and without an emulsion water repellent additive incorporated with the initial pressure treatment. Decks have been exposured for over 9 years in Harrisburg, NC. Boards were evaluated for in-service and laboratory performance for water repellent efficacy, as well as additive loadings in the boards after this exposure....
A R Zahora


How best to specify retentions of preservative treatments: kg/m3 or % (m/m)
1998 - IRG/WP 98-20151
When specifying treatments according to the European Standard EN 351-1, retentions in the analytical zone are based on the amount of product found to be effective in biological tests; this is expressed in terms of the retention of the product per unit volume (kg/m3) for penetrating treatments and per unit area (g/m2) for superficial treatments. However, to check whether the retentions have been ac...
J K Carey


Fumigation as a remedial treatment: A review of North American literature
1983 - IRG/WP 3253
The development of the use of fumigants for eliminating decay in timber and roundwood in North America is reviewed. Initial experiments on oak wilt identified volatile chemicals which eradicated decay in roundwood. Subsequently, extensive experimentation on Douglas-fir poles in service showed that treatment with chloropicrin eliminated internal decay for more than ten years. Vorlex was also quite ...
J N R Ruddick


Control of death-watch beetle (Xestobium rufovillosum Deg.) with experimental permethrin smoke generators
1982 - IRG/WP 3199
This paper presents results obtaining by monitoring population figures, the condition and reproductive state of beetles collected at weekly intervals after each annual treatment....
S J Read


An approach to testing the preventive effectiveness of preservative treatments for wooden joinery
1981 - IRG/WP 2156
The ecological sequence established in field trial samples exposed out of ground contact has shown the need for outdoor exposure in testing potential joinery preservative pretreatments. A system of exposure of L-joint units is proposed. Data obtained by examining samples destructively show promise as the basis for predicting service life after relatively short exposure periods (within 2 years)....
J K Carey, A F Bravery, J G Savory


Study of the natural durability and impregnability of a metropolitan species of tree
1986 - IRG/WP 2261
The current and predictable evolution of construction timber supply conditions is motivating research for a more efficient utilization of native woods. It is now important to determine statistically reliable impregnability values on a national scale, and to evaluate the natural durability of woods recently introduced in France, or economically important native woods....
M E Mathieu


The influence of previous anti-blue-stain preservative treatments on the fixation of CC in spruce
1997 - IRG/WP 97-30134
Freshly cut and kiln dried spruce boards were treated with 4 different anti-blue stain preservatives (ABP). After a period of 10 days allowing the samples to dry and fixate, the samples were treated with CC (chromium, copper formulation) using a vacuum pressure cycle. After impregnation the wood was steam fixed. A submersion leaching test showed differences in the leachable quantity of copper and ...
M Van der Zee, W J Homan


A comparative field test of the effectiveness of anti-sapstain treatments on radiata pine roundwood
1986 - IRG/WP 3376
Peeled radiata pine posts were sprayed with one of six antisapstain formulations, with and without a wax water-repellent additive, to evaluate the protection given by each treatment. After 3 months' outside storage the best treatments tested were 4% product Busan 30, 2% product Busan 1009, and 2% active sodium pentachlorophenoxide (NaPCP) with 1.5% borax. After 6 months' storage ...
J A Drysdale, R M Keirle


Decay resistance of resin treated wood
1999 - IRG/WP 99-30206
Selected natural resin systems were evaluated for their potential as wood protecting agents according to standard test procedures. As indicated by the European standard EN 599 both a Basidiomycete test according to EN 113 and a ENV 807 soil bed test were carried out. Six resin treatments were tested using 3 concentration or treatment levels. Using the biocidal activity criteria as usually applied ...
J Van Acker, A J Nurmi, S M Gray, H Militz, C Hill, H Kokko, A O Rapp


Treatment of messmate (Eucalyptus obliqua L'Hérit) by double-diffusion: Preliminary report
1983 - IRG/WP 3234
Modified double-diffusion is suggested as a method of impregnation for mixed tropical hardwoods for certain types of ground contact use in less developed countries. Compared with vacuum/pressure impregnation, capital costs are low and little skill is needed for the operations involved. Treatment of messmate (Eucalyptus obliqua L'Herit) rounds involving pre-heating in water prior to their ...
F F K Ampong, C-W Chin


A laboratory soil-block decay evaluation of plywoods edge-treated with preservatives
1982 - IRG/WP 2174
Preservative-treated plywood used under conditions or severe decay hazard frequently has its original, or cut edges, protected by the application of a field-cut preservative. This study uses a laboratory test method to compare the efficacy of four commercial preservative treatments against two commonly occurring brown-rot fungi. The results are not meant to indicate the service life of such treate...
R S Smith, A Byrne


Safety technique in wood preservation
1974 - IRG/WP 54
S N Gorshin, I G Krapivina, B I Telryatnikova


A new approach to the maintenance problems of wooden railway sleepers
1986 - IRG/WP 3392
The microenvironment of wooden railway sleepers is being investigated to assess their condition to determine the necessary treatment, repair and replacement criteria. The research work involves the development of an integrity tester to determine the condition of sleepers, a remedial treatment of sleepers by selective application of boric acid and a synthetic repair system....
W Beauford, P I Morris.


Groundline treatments for poles - Wedding Bells S.F. test site layout
1983 - IRG/WP 3259
R S Johnstone


Evaluation of the leach resistance and preservative efficacy of novel biocides as surface treatments applied by brush to spruce (Picea abies)
1998 - IRG/WP 98-30170
The comparative leach resistance and preservative efficacy of a number of alternative organic preservatives (available from Zeneca Specialties) and selected commercially available biocides as surface coatings to wood in Hazard Class 3 have been assessed. Two concentrations of test preservatives were applied by brush to Spruce (Picea abies), including formulation and untreated controls. A leaching ...
I M Tierney, A Bruce, D C R Sinclair, T Yeates


Thirty-four year test of on-site preservative treatments to control decay in wood above ground
1993 - IRG/WP 93-30015
This research was initiated in 1958 to investigate efficacy of various preservatives and treating methods for new lumber going into exterior structures of buildings. Post-rail units (2x4 inches) constructed of Southern Pine sapwood, Douglas-fir heartwood, and mill run western hemlock were dip- or brush-treated before or after assembly. Units were trested with pentachlorophenol in various petroleum...
T L Highley, T C Scheffer


Creosote immersion treatments in fence-posts of Castanea sativa, Pinus nigra and Pinus halepensis
1988 - IRG/WP 3488
The method of soaking in creosote was applied to fenceposts of Castanea sativa, Pinus nigra and Pinus halepensis, taking into account its easy use in the field. Absorption, retention and penetration rates were recorded and analysed. Absorption rates were higher in Pinus nigra than in Pinus halepensis, and lowest in Castanea sativa. Thin fence-posts always absorbed more preservative than thick ones...
C De Arana Moncada


The permanence of permethrin in wood preservation
1984 - IRG/WP 3288
The permanence of the synthetic pyrethroid permethrin in treated wood has been assessed for double vacuum and immersion treated Scots pine sapwood and whitewood using a 0.5% m/m solution of the insecticide in a hydrocarbon solvent. It is concluded that for all but the outermost 0.5 mm of the treated battens the distribution of the permethrin is relatively permanent. The outermost 0.5 mm appears vu...
R J Orsler, M W S Stone


Traitement de poteaux au moyen de solutions de Wolmanit CB
1974 - IRG/WP 338
J Guillemain-Thévenot, C Jacquiot


The use of bifluorides-diffusion in remedial treatments
1983 - IRG/WP 3256
A description is given about the experience to date of a 14 years' development to bring bifluorides-diffusion from laboratory evaluation to commercial service application. The described treatment is an adjunct to good design and not a replacement for it. The process is also used with an injection method for the remedial treatment of premature decayed external joinery....
H F M Nijman


Diffusion treatment plants (Latin America - Africa)
1974 - IRG/WP 333
B N Prasad


Report on the questionnaire sent out to IRG Members for the creation of a new Sub-group 4 "evaluation of superficial treatments for preventive action against basidiomycetes"
1992 - IRG/WP 92-2417
On Thuesday May 12th, 1992 a subgroup meeting was held between 16.00-17.00 h. About 50 people attended this meeting. The results of the questionnaire sent out last year to the IRG members, was discussed. The analysis as well as the practical conclussions of the discussions are retained in this document....
A R Valcke