IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 11 documents.


Evaluation of some polyurethanes as protective marine coatings for wood
1985 - IRG/WP 4115
Several polyurethane formulations were evaluated in the marine environment as possible replacements for Irish felt used on U.S. Navy minesweepers as a marine borer barrier between the main wooden hull and an outer, wooden sheathing which covers it. Pine panels coated with the candidate materials were tightly juxtaposed with untreated pine baitwood to simulate the hull/sheathing configuration, the ...
J D Bultman, J E Pinto


Summary of development of pile wrappings in Los Angeles Harbour
1987 - IRG/WP 4141
G Horeczko


Ultrastructure of degraded, CCA-treated Pinus radiata wood from a marine pile
1990 - IRG/WP 1461
During an inspection of marine piles, 12 years after installation, severe degradation was noted on one of them in the vicinity of a corroded eye-bolt. The wood was dark brown in colour and tended to crumble easily. Wood fragments were examined by light microscopy and scanning and transmission electron microscopy and were also analysed for carbohydrates and lignin. Light microscopy showed numerous ...
A P Singh, M E Hedley


The practice of using concrete on wood piling for marine use in Thailand
1982 - IRG/WP 492
The practice of using concrete on wooden poles has been carried on in Thailand for a long time in pile-houses and pier constructions which have been situated in, or partly in the sea. In such instances, the hewed round and/or square-sawn heartwood poles of naturally durable timber species have been coated with concrete of about 5 to 10 cm or more in thickness, and to about 100 cm above the highest...
B Anuwongse


Premature failure of treated timber in wharfs in Papua New Guinea, attributed to defects in design
1991 - IRG/WP 4158
The performance of timber in wharfs in Papua New Guinea has been monitored for a number of years. Premature failure of wharf structures was found in many cases to be due to defects in design rather than ineffective preservative treatment. Above-water timbers were found to be prone to severe checking followed by decay. Protection for the end grain of pile tops and the limiting of radial checking in...
S M Cragg


Protection of pile tops using combinations of internal treatments and water shedding caps
1993 - IRG/WP 93-30020
Preservative treatment produces an excellent barrier against fungal, insect, and marine borer attack; however, fabricators often disrupt this barrier during construction, creating avenues for entry of decay agents. This problem is particularly acute in marinas along the coastal United States. Standards recommend the application of a water-shedding cap at the time of installation to prevent pile to...
P Schnieder, M A Newbill, J J Morrell


Expected service life of outdoor wooden structures such as guard fences and noise barriers indicated by questionnaire survey
2007 - IRG/WP 07-20372
Forestry Agency, Japan has intended to expand the utilization of domestic wood in many areas such as not only housing constructions also outdoor structures. In order to respond the policy, actual durability and service life of these structures should be clarified, and the guide line for archiving planned service life also should be established. Japan Wood Preservers Industries Association carried ...
K Yamamoto, A Makita, A Yamaguchi, T Shiraishi, K Maeda, D Tezuka, S Katsumata, M Higaki


Conclusions and Summary Report Environmental Life Cycle Assessment of Highway Guard Rail Posts
2013 - IRG/WP 13-50297
The Treated Wood Council has completed a quantitative evaluation of the environmental impacts associated with the national production, use, and disposition of treated wood and galvanized steel highway guard rail posts using life cycle assessment (LCA) methodologies and following ISO 14044 standards. The results for treated wood guard rail posts are significant. • Less Energy & Resource Use: ...
AquAeTer, Inc.


Foundation piles: analysis of beech wood decay in service life conditions
2016 - IRG/WP 16-10858
Wood piles foundation system was largely used over decades. Thus, numerous buildings over the world are based on this constructive system. In the context of reduction of CO2 emissions in the building field of constructions, substitution of concrete by wood as material for foundation piles seems to be a promising alternative. However, fluctuation of the water table level in soil may promote fungal ...
Q Kleindienst, A Besserer, M-L Antoine, C Perrin, J-F Bocquet, L Bléron


Assessment of the quality and lifetime of wooden pile foundations
2017 - IRG/WP 17-10883
The development of wooden pile foundations started centuries ago and enable man to build and live in strategic and fertile areas. Although the building methods, the building materials and the building regulations chanced especially over the last decades, worldwide wooden pile foundations still fulfil their function to support above ground constructions of which many belong to our cultural heritage...
R W W M Klaassen, A Jorissen, H Keijer


Effect of damage to polyurea coatings on metal losses from ammoniacal copper zinc arsenate treated Douglas-fir pile sections
2019 - IRG/WP 19-40867
Metal-based preservatives remain the most widely used treatments for protecting wood in soil or water contact. While these treatments are highly effective, one drawback is a tendency for small amounts of metal to migrate into the surrounding environment. The greatest risk in this regard is copper because many organisms are highly sensitive to this metal. While post treatment practices can reduce ...
M J Konkler, J J Morrell