IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 473 documents. Displaying 25 entries per page.


European laboratory termite testing
1986 - IRG/WP 1299
As with all testing of wood preservatives the evaluation of the resistance to termites of treated wood requires methodology which is approriate to, and can be readily extrapolated to, the practical situation. Thus not only must the variations in possible treatment systems be taken into account (eg dip, brush or pressure application) so too must the range of termite species and the type of exposure...
R W Berry


The case for non-chemical termite barriers in termite control
1989 - IRG/WP 1381
A brief outline of current non-chemical barriers in subterranean termite control and their use in Australia is presented. Recent use of non-chemical barriers in Hawaii has led to their evaluation in termite control here and elsewhere. In Australia, preliminary laboratory and field experiments have shown similar results to those found against Coptotermes formosanus in Hawaii, namely, Australian Cop...
J R J French


Wood protection by surface treatment of two borate preservatives, TIM-BOR® and BORA-CARE®, for the formosan subterranean termite and eastern subterrean termite
1993 - IRG/WP 93-10044
TIM-BOR® (disodium octaborate tetrahydrate: DOT, Na2B8O134H2O) and BORA-CARE® (40% DOT in ethylene glycol) are two borate products marketed for treating wood in use by brushing or spraying onto the wood surface. The active ingredients presumably diffuse into wood by the 10-15% existing wood moisture. Few data, however, are available to demonstrate the diffusion rate. Su & Scheffrahn (1991) s...
M Toroko, N-Y Su


Size of food resource determines brood placement in Reticulitermes flavipes (Isoptera: Rhinotermitidae)
2000 - IRG/WP 00-10351
Most species of subterranean termite house and care for larvae in specialised chambers or complex nurseries. In addition to these chambers, the genus Reticulitermes also keeps larvae at sites where foragers are feeding, a trait more commonly found in damp wood and dry wood termites. This phenomenon of holding larvae at foraging sites is quite well known among researchers who work with Reticuliterm...
M Lenz, B M Kard, J K Mauldin, T A Evans, J L Etheridge, H M Abbey


Further thoughts on standard principles of testing termiticides and/or wood preservatives
1992 - IRG/WP 92-1530
At the last annual meeting in Kyoto, Japan, there was a special session devoted to the standard principles of testing termiticides. There was definitely a perceived need by researchers and industry for some guidelines that spell out basic procedures required for any methodology in testing termiticidal formulations anywhere in the world. In the testing of new potential active ingredients, considera...
J R J French


Using AE monitoring for detecting economically important species of termites in California
1991 - IRG/WP 2375
Acoustic emission (AE) monitoring was conducted on wooden samples containing three economically important species of termites in California (dampwood termite, Zootermopsis nevadensis, Western drywood termite, Incisitermes minor, and Western subterranean termite, Reticulitermes hesperus). Laboratory AE studies included varying termite species, as well as 7 day studies exploring the periodicity of t...
V R Lewis, R L Lemaster, F C Beall, D L Wood


A rapid method for collecting large numbers of subterranean termites from wood
1982 - IRG/WP 1165
A corrugated fiberboard trap is described which attracts large numbers of subterranean termites from infested logs. Single-trap collections in excess of 63 grams (wet wt.) for Reticulitermes virginicus (Banks) and 43 grams for Coptotermes formosanus Shiraki were taken one to three days following discovery by termites. If traps are removed from the source logs shortly after beeing attacked, termite...
J P La Fage, N-Y Su, M Jones, T Lawrence


An evaluation of the synthetic pyrethroid cypermethrin in organic solvent and emulsion formulations
1984 - IRG/WP 3290
The studies reported indicate that cypermethrin (NRDC 149) has considerable potential as an insecticide for wood preservatives. Cypermethrin appears to be about twice as effective as permethrin. The effectiveness of cypermethrin compared with g-HCH varies depending on the insect species, the phase of the life cycle and size of larva: for example, against mature Anobium larvae cypermethrin is appro...
S J Read, R W Berry


Borate-treated food affects survival, vitamin B12 content, and digestive processes of subterranean termites
1990 - IRG/WP 1448
Toxicity of boron compounds was studied by analyzing survival rates and vitamin B12 contents in Formosan subterranean termites, Coptotermes formosanus Shiraki, that were exposed to dietary treatments for 10 days. The dietary treatments applied in moistened cellulose were (a) 0.05% boric acid equivalent (BAE) of disodium octaborate tetrahydrate, (b) 0.05% BAE of anmonium pentaborate plus sodium sul...
L H Williams, S I Sallay, J A Breznak


Subterranean termite attack potential in field test sites: assessment methods and field characterization
2003 - IRG/WP 03-10472
To assess subterranean termite attack potential in the field and seasonal variations, trials were set up in each of two managed silvicultural plantations, of Eucalyptus globulus and Pinus pinaster, respectively. Termite occupancy in lying dead wood was evaluated by an adaptation of the line-intersection method, and attack potential in soil was assessed by a system of stakes inserted into the groun...
T Nobre, L Nunes, L Brinca, D E Bignell


Laboratory termite testing of copper boron tebuconazole
2000 - IRG/WP 00-20192
The American Wood Preservers' Association laboratory choice and no choice termite test (AWPA E1-97) was performed on a formulation of copper azole, which is comprised of copper, boric acid, and tebuconazole. The formulation tested has a ratio of copper:boric acid:tebuconazole of 25:25:1. So as to examine the impact of leaching, the southern yellow pine wafers were treated with and without...
R F Fox, E A Pasek, J Patel


Soil termiticides: A review of efficacy data from field tests
1987 - IRG/WP 1323
This paper reports efficacy data from the field evaluation of various soil termiticides by the U.S. Department of Agriculture, Forest Service, Gulfport, Mississippi. These chemicals, which include a number of chlorinated hydrocarbon, organophosphate, pyrethroid, and carbamate insecticides in a range of concentrations, have been in long-term tests at seven field sites. Data are reported for the gro...
J K Mauldin, S C Jones, R H Beal


Isolation and identification of the trail pheromone of the subterranean termite Reticulitermes speratus (Kolbe) (Isoptera: Rhinotermitidae)
1990 - IRG/WP 1459
The trail pheromone was successfully isolated from whole body extract of the termite Reticulitermes speratus (Kolbe) through various chromatographic reactions. Its trail-following activity was examined by bioassays. The primary structure of the pheromone was determined as normal chain dodecatrien-1-ol by capillary GC-MS analysis. Moreover, by means of capillary GC-MS and capillary GC-FTIR analyses...
M Tokoro, M Takahashi, R Yamaoka


Evaluation of tropical wood by-products as a potential source for termite control products
2001 - IRG/WP 01-10408
Termites damaging in houses represent an ever growing threat in Europe, where the phenomenon has accelerated during the last ten years, as well as in the tropics, where infestations are permanent. To fight against this plague, the current methods used, through injection of organochloric or organophosphorized products into the timber structures and walls, are belonging to the past due to the toxici...
A Zaremski, S Robert, J-L Clement, D Fouquet


Remedial wood preservative efficacy of BORA-CARE against the Formosan subterranean termite and eastern subterranean termite (Isoptera: Rhinotermitidae)
1991 - IRG/WP 1504
When a spruce board (3.8 cm x 8.8 cm x 2.4 m) was surface-sprayed with BORA-CARETM solution (containing 23% disodium octaborate tetrahydrate) and stored in an air-conditioned room (24 ± 2°C and 60 ± 5% RH) for eight months, ca. 40% of the wood (measured by the cross section surface proportion) contained borates at the rate of >2,500 ppm BAE (boric acid equivalent). In a choice bioassay, term...
N-Y Su, R H Scheffrahn


Silafluofen: Novel chemistry and versatility for termite control
1995 - IRG/WP 95-30069
A novel silicon - containing insectizide, HOE 084498 ('Silafluofen'), with a favourable toxicological profile, has shown activity against a broad spectrum of agricultural and environmental health pests. Results from laboratory and field studies around the world have demonstrated that silafluofen is effective at protecting timber from attack by various species of termite and wood-...
A J Adams, A Jermannaud, M-M Serment


Termiticide degradation in Mississippi field tests
1994 - IRG/WP 94-30052
Degradation rates of some currently marketed United States termiticides are currently being studied. Separate quantities of soil were each treated at lowest label rates with termiticide, and placed in trenches along the inside and outside of concrete walls. Composite soil samples, each consisting of four soil cores, were collected after 1, 30, 60, 120, 180, 240, and 365 days, and again at 2 and 3 ...
B M Kard


Performance of Borate-Treated Wood Against Reticulitermes flavipes in Above-Ground Protected Conditions
2003 - IRG/WP 03-30309
Termites cause economically significant damage in Canada only in a few localized areas. However, one of those is in Canada’s largest city, Toronto, Ontario. In 1996, a test was set up of borate-treated lumber above ground, protected from rain but exposed to subterranean termites (Reticulitermes flavipes) in Kincardine Ontario. The material included western hemlock and amabilis fir lumber trea...
P I Morris, J K Grace, K Tsunoda, A Byrne


The density factor in termite bioassays
1985 - IRG/WP 1252
The initial and final floor surface and food block surface actually used by termites in a small container were converted to estimates of "Living Space" and "Feeding Space" densities for 1/32 to 1½ g groups of termites. The termites were provided with blocks of blotter paper as a food supply. Except where 1½ g groups exhausted the food, the survival of termites was uniformly high (averaging >9...
G R Esenther


Laboratory method for testing the effectiveness of soil termiticides
1992 - IRG/WP 92-1561
In France, the protection of buildings against termites is based on a chemical treatment of wood, soil and walls. Because of the withdrawal of aldrin from the market, the need of new soil termiticides has appeared. Therefore, a laboratory method derived from Cymorek's method has been developped to assess their effectiveness. Some points are developed like the type of soil, the number of t...
M-M Serment, A-M Pruvost


Laboratory trials of biological control agents against subterranean termites
1991 - IRG/WP 1475
To screen for potential termite control by microorganisms, 17 mold fungi included 3 pathogenic fungi and 7 basidiomycetes, were used to challenge the test termite species, Coptotermes formosanus and Reticulitermes speratus. Test fungi were allowed grow and completely in Petri dishes. To screen for potential termite control by microorganisms, 17 mold fungi included 3 pathogenic fungi and 7 basidiom...
K Suzuki


The effect of boric acid on the protozoan numbers of the subterranean termite, Reticulitermes lucifugus
1996 - IRG/WP 96-10148
Lower termites harbor in their guts populations of microorganisms known to be indispensable for their survival, being responsible, at least partially, for the digestion of cellulose, the main item of termites'diet. The Reticulitermes species in particular harbor in their hindguts some unique intestinal fauna, for instance protozoa belonging to the genera Pyrsonympha, Dinenympha and Trycho...
L Nunes, D J Dickinson


Efficacy of termiticide treatments to soil in field tests in the southern United States
1994 - IRG/WP 94-30043
In standard ground-board and concrete-slab efficacy tests in the southern United States, termiticides provide several years of subterranean termite control depending on rates applied to the soil and test site location. Years of 100% control (as of February 1994) provided by each currently marketed termiticide applied at highest label rates under concrete slabs in our four primary test sites (Flori...
B M Kard, J K Mauldin


Termite resistance of treated wood in an above-ground field test
1985 - IRG/WP 2241
A field test method has been developed for evaluating the susceptibility of wood products to termites in protected situations above ground. In this method fungal attack on the wood products is minimal, though decay has been observed in conjunction with termite attack in some specimens. Preliminary results from exposure of replicate wood samples treated with preservatives in Florida to Reticuliterm...
A F Preston, P A McKaig, P J Walcheski


Detrimental effects of boric acid on symbiotic protozoa in Reticulitermes flavipes (Kollar) and Coptotermes formosanus Shiraki (Isoptera: Rhinotermitidae)
2000 - IRG/WP 00-10366
In laboratory choice bioassays, Reticulitermes flavipes (Kollar) and Coptotermes formosanus Shiraki were offered a tunneling soil consisting of boric acid (BA) mixed with sterilized soil at concentrations of 0.05, 0.25, 0.50, 1.00, 2.00, or 4.00 percent AI (wt:wt). Termites could choose to remain in their main nest that contained non-treated artificial substrate and adequate food, or tunnel throug...
B M Kard


Previous Page | Next Page