IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 307 documents. Displaying 25 entries per page.


Laboratory simulation of leaching from creosote treated wood in aquatic exposures
2000 - IRG/WP 00-50157
Creosote has a long history of use as a preservative particularly in industrial wood products, but its use has come under increasing scrutiny as a result of concerns about its potential effects on aquatic and terrestrial non-target organisms. Despite its long use, there is relatively little data on the rates of creosote loss in many exposures. In this report, we describe small scale leaching tank ...
Ying Xiao, J Simonsen, J J Morrell


How to Document the Performance of Super-Critical Treated Wood in above Ground Situations?
2005 - IRG/WP 05-20316
The paper presents practical experiences from the preparation of a new preservative treated wood product for introduction to the market. The product in question is Superwood™, which is treated with organic biocides using CO2 in a supercritical state as a solvent. The question is how to evaluate the performance of a new product such as Superwood™ in order to get an acceptance on the market a...
N Morsing, A H H Wong, F Imsgard, O Henriksen


Influence of different fixation and ageing procedures on the leaching behaviour of copper from selected wood preservatives in laboratory trials
2003 - IRG/WP 03-20264
The paper focuses on the role of different parameters, such as fixation, sample size, wood species, and leaching in internationally standardized ageing procedures for wood preservatives from Europe, Japan and the United States. The leaching protocols used were EN 84, JIS K 1571 and AWPA E11 protocols. The wood species were Scots pine, Sugi and Southern Yellow Pine respectively. Three types of com...
J Habicht, D Häntzschel, J Wittenzellner


IRG Working Group II. Co-operative leaching test (letter to collaborators)
1974 - IRG/WP 240
J W W Morgan


Pinus and Eucalyptus fenceposts treated with creosote and solvex tar by hot and cold open-tank process
1987 - IRG/WP 3455
A comparative study of the behaviour of two different wood preservatives, creosote and solvex-tar, was made, using two wood species, Pinus pinaster Ait and Eucalyptus globulus Labill, by the hot and cold open-tank process. Results showed that the creosote behaved better in relation with the uniformity of its distribution in wood. On the other hand, better results were obtained on Pinus for both pr...
M V Baonza Merino


Leaching of the new boron based biocide from coated wood
2001 - IRG/WP 01-30267
We investigated leachability of the new boron based biocide - a complex of an amine and boric acid - from vacuum impregnated spruce wood samples. It was determined by the standard ENV 1250-2 procedure that the new biocide is susceptible to leaching so from the water borne as well as from the ethanol borne boron containing preservative treated wood. Leaching may be retarded by application of surfac...
M Petric, M Pavlic, F Cadez


Effect of water repellents on leaching from CCA treated wood
1995 - IRG/WP 95-50044
CCA treated fence boards brushed with a water repellent finish had consistently lower leaching losses of all CCA components compared to the rate for matched samples without the water repellent. These results are after 12 cycles of simulated rainfall in the laboratory (1800 mm rainfall total) and four months of natural rain exposure in Toronto....
P A Cooper, R MacVicar


IRG Working Group II. Co-operative leaching tests
1973 - IRG/WP 230
J W W Morgan


Collaborative soft rot tests: Programme and test method
1973 - IRG/WP 229
J G Savory, J K Carey


Creosoted radiata pine by non-pressure methods
1988 - IRG/WP 3486
Posts of Pinus radiata have been impregnated with creosote by immersion for 1, 3, and 7 days, and by hot-and-cold open tank with hot bath temperatures at 40°C and 60°C. On the basis of the retention rates obtained, suitable procedures are described for wood elements that are going to be in ground contact, and an analysis is made of the way in which the variables tested affect the results....
M V Baonza Merino, C De Arana Moncada


Problems of fixation of CCA-preservatives in palm-wood
1985 - IRG/WP 3338
Palm-wood may be used for posts and poles where it needs proper treatment for long time use. Based on observations by W. Killmann on low CCA-fixation in palm-wood, samples of Jubaea-palm grown in a Greenhouse at Hamburg, have been treated in two different series with a 4% solution of CCA-type B. After 1-16 weeks of storage the blocks were split into sticks of 1-2 mm² and leached. In all series 50...
H Willeitner, K Brandt


Studies on accelerated ageing procedures with TBTO-treated wood
1985 - IRG/WP 2244
The efficacy of various procedures for accelerated ageing of organotin based wood preservatives in treated wood has been investigated. It was found that leaching of the treated wood samples in water according to the European Standard EN 84 was not satisfactory for organotin based preservatives and is probably also unsuitable even for other types of organic solvent preservatives. Keeping tributylti...
J Jermer, M-L Edlund, B Henningsson, W Hintze


Leaching of components from water-borne paints and fungitoxic effects
1995 - IRG/WP 95-20062
Water-borne model paints, acrylics and alkyd emulsion paints, of known composition were leached according to a procedure modified in accordance with ASTM 6271.1. The effectiveness of fungicidal compounds in the painted specimens before and after leaching was evaluated with a biotest in which Penicillium brevicompactum was used as a test fungus. The leaching of the fungicide Troysan Polyphase accor...
J Bjurman


Problem of the treatment of dried sawn spruce building timbers with water-borne preservatives. Interim reports for discussion at the 4th Annual Meeting in West Berlin on 27 October 1972
1972 - IRG/WP 311
One of the most difficult technical problems facing the preservation industry is how to improve the treatment of refractory species of timber such as spruce. Its resistance to penetration, even under pressure' precludes its use for more hazardous service situations, and even in less severe conditions a higher level of treatment would be desirable. The importance of this subject led us to ...
W Liese, J W W Morgan, T Hof, R O Ullevålseter


Cu, Cr and As distribution in soils adjacent to CCA treated utility poles in Eastern Black Sea Region of Turkey
2004 - IRG/WP 04-50214
In this study, the main objective was to asses the distribution of Cu, Cr, and As in soils adjacent to CCA treated utility poles in Eastern Blacksea Region of Turkey (Trabzon, Rize and Artvin ) and determine the influence of soil composition. Surface (0-5cm), subsurface soil samples (30-40cm) were collected near CCA-treated utility poles and control soil samples away from CCA-treated utility pole...
E D Gezer, Ü C Yildiz, A Temiz, S Yildiz, E Dizman


The leaching of copper, chrome and arsenate from CCA-impregnated poles stored for ten years in running water
1978 - IRG/WP 3122
There is no evidence to indicate that the chromium and copper components are leached from the outermost 5 mm of sapwood in poles impregnated with Boliden K33 and Tanalith C and stored in running water for ten years. The arsenic component, however, seems to be leached out during the first few months to an extent of about 20% of the initial amount. The leaching time is dependent on the preservative ...
F G Evans


A discussion of current theories concerning CCA fixation
1983 - IRG/WP 3238
The understanding of the fixation mechanism of CCA and related preservatives in wood has been greatly improved by a significant series of recent scientific papers. In view of recent concerns in New Zealand regarding the long-term efficacy of CCA in high decay-hazard situations, it was considered appropriate to review this recent work and to contrast it with theories presented by previous workers....
D V Plackett


A simple leaching procedure for in-plant monitoring of CCA fixation
1993 - IRG/WP 93-30023
A simple leaching test is described to quantitatively estimate the extent of fixation of chromated copper arsenate (CCA) preservative treated wood products. It is based on the reaction between diphenylcarbazide and unreacted hexavalent chromium leached from borings taken from treated wood during the fixation process. The test requires about 20 minutes to complete and can be set up in a treating pl...
P A Cooper, Y T Ung


Use of vermiculite as substrate in assays on phytotoxicity of treated wood
1989 - IRG/WP 3547
It is considered the possibility of using vermiculite instead of soil as substrate in assays on phytotoxicity of wood treated with preservatives for agricultural use. Three organic preservatives were used. It had been tested the behaviour of both, vermiculite and soil in case of preservative leaking due to a leach. So that, assays of germination with cucurbitaceous were carried out, mixing a dose ...
M V Baonza Merino, D Franco


Depletion of boron and copper from CCB treated test specimens using different leaching protocols
2004 - IRG/WP 04-50208
The objective of this study was to measure the depletion of inorganic wood preservative components regarding the proposed OECD guideline "Estimation of emissions from preservative-treated wood to the environment: laboratory method for wooden commodities exposed in the use class 4 and 5" as part of the project "Investigations concerning the influence of test parameters on the release of biocidal ac...
E Melcher, R-D Peek, U Schoknecht, R Wegner


Local preservation with difluoride pills: Life-time of preservative
1998 - IRG/WP 98-40127
A brief history of the situation in the Netherlands with respect to the preservation of joinery is given. Already in the eighties in the Netherlands many spruce window frames were treated with difluoride pills. One of the possible disadvantages of this kind of diffusing preservatives is the high leaching rate found in laboratory situations. The leaching rate in practice is influenced by many facto...
W J Homan, C Blom, B W Holleboom


Leaching of copper, chromium and arsenic from CCA-treated Scots pine exposed in sea water
2000 - IRG/WP 00-50149
A laboratory leaching trial combining a static and a flowing seawater system was carried out to measure the leaching rates of copper, chromium and arsenic from the surface of Scots pine panels vacuum-pressure treated to 3, 6, 12, 24, and 48 kgm-3 CCA. Untreated and treated panels were exposed in flowing seawater for up to 8 weeks followed by 2 weeks submersion in static seawater which was taken fo...
C J Brown, R A Eaton


Procedure for a collaborative study of leaching from CCA-treated timber in the sea
1988 - IRG/WP 4143
As a follow-up to the collaborative IRG/COIPM marine trial of CCA and CCB preservatives, a further trial is proposed with the objective of measuring the degree of leaching of CCA components from three timber species at marine sites in Malaysia and the U.K.. Details of the planned procedure are given....
S M Cragg, J E Barnacle, J D Bultman, R A Eaton, B R Johnson, L E Leightley, K D Singh


Performance results of wood treated with CCA-PEG
1986 - IRG/WP 3363
The addition of polyethylene glycol (PEG) to the CCA system has been shown to reduce the surface hardness of poles and ease spur penetration during climbing. This paper addresses the results of tests dealing with preservative retention and penetration, permanence of CCA and PEG, strength, drying rate, and checking characteristics....
W P Trumble, E E Messina


IRG Working Group II. Co-operative leaching test (letter to collaborators)
1974 - IRG/WP 234
J W W Morgan


Next Page