IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 22 documents.


An evaluation method for less termite attack execution on thermal insulation for fundation walls
2002 - IRG/WP 02-20245
According to the results by the real scale Japanese building tests, the termite installation was observed at very little spaces between foundation and insulation. The termite penetration spaces between foundation and insulation on foundation systems in Japanese wooden houses were checked by the way of streaming speed of colored water. Because of difficulty for its execution, the parts of outside a...
K Suzuki, Y Tanaka


IRG Foundation Fund Report
1985 - IRG/WP 5215
B Henningsson, H Friis-Hansen


Japanese wood preserving industry
1990 - IRG/WP 3596
Although a great amount of wood is in use in Japan, a little attention has been paid to the significance and importance of wood preservation. The fact reflects that only less than 0.5% of the total wood consumption is treated with wood preservatives today in the country. Over the 20 years before 1970, the annual volume of preservative treated (pressure treatment) wood was relatively at a stable le...
K Tsunoda


IRG Foundation Fund Report
1984 - IRG/WP 5197
B Henningsson


IRG Foundation Fund Report for 1979
1980 - IRG/WP 97
L Borup, B Henningsson


Experimental real building evaluation of termite attack - Effect of the space between the mat foundation and the thermal insulation
2000 - IRG/WP 00-10374
For evaluating the termite resistance of the real house foundation, specially in the case of thermal insulation systems for foundation walls, thermal insulation which can be attacked by termite, must be evaluate. Because of the difficulty of the water penetration of thermal insulation, the water barrier systems can be protected against termite attacks, in our opinions. The observation on the proce...
K Suzuki, K Hagio, Y Tanaka


IRG Fundation Fund Report for 1987
1988 - IRG/WP 5321
B Henningsson, H Friis-Hansen


IRG Foundation Fund Report for the period 1 January to 31 December 1988
1989 - IRG/WP 5344
B Henningsson, H Friis-Hansen


IRG Foundation Fund Report 1976-1978
1979 - IRG/WP 90
L Borup, B Henningsson


IRG Foundation Fund Report for 1985
1986 - IRG/WP 5248
B Henningsson, H Friis-Hansen


IRG Foundation Fund Report 1981
1982 - IRG/WP 5157
L Borup, B Henningsson


IRG Foundation Fund Report for 1986
1987 - IRG/WP 5281
B Henningsson, H Friis-Hansen


IRG Foundation Fund Report for 1981
1981 - IRG/WP 5127
L Borup, B Henningsson


Studies on the infesting behaviour of the Formosan termite, Coptotermes formosanus Shiraki and its physical control
1983 - IRG/WP 1174
An outline of termite damage to buildings in Japanese National Railways, wood-infesting behavior, attacked traces in PVC-sheathed cables by termites, detection method of termites and the physical control method of the Formosan termite are given in the present paper....
K Yamano


IRG Foundation Fund Report for 1982
1983 - IRG/WP 5176
L Borup, B Henningsson


Decay rates and strength and stiffness loss in foundation beams
1992 - IRG/WP 92-1563
The TNO Centre for Timber Research has executed an extensive research programme into the rate of decay in foundation beams, as a result of lowering of ground water tables. The aim of the research was to develop a method, predicting the decrease in strength and stiffness in beams, due to wood decay during drytime of foundation beams. With the calculated extremes in decay, the damage caused by local...
P Esser, H S Buitenkamp


Developments in wood preservation
1976 - IRG/WP 366
The purpose of this paper is to comment very briefly upon recent developments in wood preservation so that members of the Working Group have a basic knowledge of the activities in other countries. The last paper was prepared in 1974 and this paper refers to developments since that time. The last edition of this paper was welcomed by members of IRG. Many members wrote to the author to express their...
B A Richardson


The effect of different foundation systems against fungal flora in the crawl space of a new wooden Japanese house
2009 - IRG/WP 09-10700
In order to establish novel preventive measures against damage of wooden houses by decay fungi with less-use or no-use of chemicals, we periodically monitored the fungal flora in the crawl space of a new wooden Japanese house build with recyclable and low-environmental load materials at the Research Institute for Sustainable Humanosphere, Kyoto University. We employed either a layer of concrete or...
A Toyoumi, S Horisawa, T Yoshimura, S Doi,Y Imamura


Protective Levels of Borates in timber Foundation Piles 5 – 18 Years after In-situ Remedial Treatment in Areas with Wet Clay Ground Conditions. The Jerbor and Eurobor Protocol, Part 1.
2011 - IRG/WP 11-30571
Timber has been used as foundation piles and grillages for decades or even centuries. Since the late 1970s a method for investigate, analyze and treat building timber foundations in soft clay grounds against decay fungus with a biocide have been developed and used by the late professor Allan Jerbo. Settling of buildings in soft clay grounds is continuously monitored and if damages to the building ...
M Theorin, K-M Bandh


Effectiveness of Water Based Bentonite-Borate Slurry for In-situ Remedial Protection of Historic Wooden Piles: The Eurobor Protocol, Part 2
2011 - IRG/WP 11-30574
The study of the biocide product Eurobor®, water mixture of boric acid, borax and sodium bentonite, aimed to verify previous findings regarding borates penetration from a clay-water mixture of foundation timber. The product was applied on samples from 100 year old timber foundation from the city of Göteborg. Although in ground for this long the timber was in acceptable god condition due to groun...
M. Theorin, K. Fimmerstad, K-M. Bandh


Termiticide Residues in Building Foundation Aggregate Fills After Trench and Surface Applications
2015 - IRG/WP 15-30679
Termiticide concentrations (ppm) in aggregate fill were determined by measuring active ingredient (a.i.) residues of two pyrethroid termiticides, Up-Cyde Pro® 2EC-cypermethrin, and BaseLine® EC-bifenthrin, at 24.0 hours, and then at 6.0- and 12.0-months after ‘horizontal’ surface applications, perimeter ‘trenching and rodding’ applications, or ‘rodding only’ trench applications at lo...
B M Kard, C E Koneman, K T Shelton, C C Luper, R A Grantham


Foundation piles: analysis of beech wood decay in service life conditions
2016 - IRG/WP 16-10858
Wood piles foundation system was largely used over decades. Thus, numerous buildings over the world are based on this constructive system. In the context of reduction of CO2 emissions in the building field of constructions, substitution of concrete by wood as material for foundation piles seems to be a promising alternative. However, fluctuation of the water table level in soil may promote fungal ...
Q Kleindienst, A Besserer, M-L Antoine, C Perrin, J-F Bocquet, L Bléron