Your search resulted in 707 documents. Displaying 25 entries per page.
Some Experiences with Stake Tests at BAM Test Fields and in the BAM Fungus Cellar
Part 1: Comparison of Results of Visual Assessments and Determinations of Static Moduli of Elasticity (MOE)
2005 - IRG/WP 05-20319
With examples of routine in-ground stake tests differences are shown in the performance of wood preservatives at the BAM test fields Lehre and Horstwalde and in the BAM fungus cellar. Signs of attack of micro-organisms were assessed visually according to EN 252. Periodical determinations of static moduli of elasticity (MOE) revealed the influence of the attack on the elastic properties of the wood...
M Grinda, S Göller
Blue stain in timber in service. Progress review of Sub-group collaborative tests - 1981/82
1982 - IRG/WP 2178
Following from the discussions after reporting Document IRG/WP/2146 at the Meeting in Sarajevo, 1981, it was decided that 1.) more precise definition was needed of the artificial weathering schedules used in the work - participants to re-check Table 8 and send further details or amendments to Dr Bravery; 2.) a further test employing a wider range of chemicals was necessary using a smaller range of...
A F Bravery, D J Dickinson
Hole delimination inside round timber via ultrasonic techniques
1990 - IRG/WP 2358
A fast and economic circular scanning method to localize and evaluate holes inside round timber is presented. This method consists in measuring transit times of the ultrasonic wave by fixing the transmitter probe in the perimeter of the sample, then moving the receiver probe every ten degrees until completion of the circle. The scanning is done with a cheap and light instrument. Tests are made wit...
G Prieto, A Fernández Cancio
Variation in field test performance of untreated and CCA-treated lesser-known Surinamese wood species
2000 - IRG/WP 00-20213
In Suriname three different field test sites have been used to verify the biological durability of CCA-treated wood and a range of wood species including lesser-known and lesser-used wood species. In total 37 tropical wood species were tested untreated and for 17 of the less durable species CCA-treatments were included as well. Although the three sites are located in the tropical region they diffe...
J Van Acker, M Stevens, L Comvalius
Testing durability of treated wood according to EN 252. Interpretation of data from Nordic test fields
2006 - IRG/WP 06-20341
To evaluate the effectiveness of new wood preservatives intended for treated wood in ground use there is a European standard, EN 252. The test shall run for five years before any formal interpretation of the results can be made.
Due to environmental concerns, the use of wood preservatives based on copper, chromium and arsenic (CCA) has been restricted in recent years. As a consequence of restrict...
M L Edlund, F G Evans, K Henriksen, T Nilsson
L-joint based testing for service life prediction of exterior plywood in out of ground contact conditions
2006 - IRG/WP 06-20342
Good biological performance of several plywood types in exterior conditions is most probably related to altered wood moisture behaviour compared to solid wood. Therefore a test set up was developed, using EN 330 L-joint testing methodology, to facilitate differentiation of plywood for exterior applications.
The proposed test set up is an adaptation of an accelerated L-joint method introduced by V...
J De Smet, I De Windt, J Van Acker
Performance of Preservative Treated Parallel Strand Lumber in Marine Exposures.
2006 - IRG/WP 06-30407
The performance ACZA treated Douglas-fir and CCA southern pine parallel strand lumber (PSL) was studied in marine exposures in Florida or Oregon. While materials treated to retentions below the recommended levels for marine exposure were attacked in Oregon, properly treated panels of either species performed well. Panels treated with these same chemicals and exposed in Florida experienced attack ...
J J Morrell, C S Love, P Merrick
Testing biological durability of wood-plastic composites
2006 - IRG/WP 06-20347
Testing biological durability is inherently different for wood-plastic composites (WPC) compared to solid timber. However there is clearly a need for more information on the durability of WPC’s, on the effect of decay on the material properties of WPC’s and on methods for assessing decay of WPC’s. For the emerging European WPC market there has been some discussions on how to work on these to...
J Van Acker
Standard Test Methods for Wood Preservatives by Laboratory Agar-Block Test
2006 - IRG/WP 06-20350
Wood is one of the most valuable and versatile resources for all sorts of constructional purposes. But timber in its various forms is subjected to several types of deterioration. This standard lays down the method for the laboratory determination of threshold value of wood preservatives against fungi. Most chemicals are initially tested for their ability to control decay fungi in agar-block tests....
P K Sarker, M A Rahman, M R Bulbul, T Das, G N M Ilias
Exposure of CCA and ACZA treated parallel strand lumber to marine borer attack in northeastern and southeastern waters of the United States of America
2006 - IRG/WP 06-30400
Southern pine and Douglas fir Parallel Strand Lumber (PSL) panels were treated with chromated copper arsenate (CCA) or ammoniacal copper zinc arsenate (ACZA), respectively and exposed in a marine environment in Massachusetts (northeastern USA coast) for 7 years. Similarly treated panels were also exposed to a site on the Atlantic coast Florida (southeastern USA) for the same period. In the northe...
B Goodell, P Merrick, J Jellison, Y Qian
Long term marine performance of ACZA treated Hem fir in Krishnapatnam harbour, east coast of India
2006 - IRG/WP 06-30409
The performance of Hem fir (Tsuga heterophylla) and Southern pine (Pinus sp.) treated with ammoniacal copper zinc arsenate (ACZA) and copper dimethyldithio carbamate (CDDC) at two retention levels of each preservative was assessed in tropical marine waters at Krishnapatnam harbour on the east coast of India. Panels treated with ACZA of lower loadings (23.1 Kg/m3) had failed in 38 months while the ...
B Tarakanadha, K S Rao, J J Morrell
Resistance of DMDHEU-treated pine wood against termite and fungi attack in field testing according to EN 252. Results after 30 months
2006 - IRG/WP 06-40354
The aim of this study was to determine the effectiveness against decay and termite attack of pine sapwood treated with pure and modified DMDHEU in a field test according to European Standard EN 252. Some of the treatments tested were able to increase, within the period of the test reported (30 months), the resistance of the wood both to micro-organisms and termites. The curing process seems to be ...
S Schaffert, L Nunes, A Krause, H Militz
Leaching of CCA from Paraserianthus falcataria panels exposed to field conditions at Krishnapatnam harbour, Andhra Pradesh
2006 - IRG/WP 06-50241
This study assessed the leaching of copper, chrome and arsenic (CCA) from Paraserianthus falcataria (=Albizia falcataria) panels exposed to marine condition at Krishnapatnam harbour on the east coast of India. Metal loss was assessed in test panels after 6, 12, 24 and 36 months of exposure using Atomic Absorption spectrophotometer (AAS). The metal loss was found slightly higher in panels treated ...
B Tarakanadha, K S Rao
Current state of world standardization in the toxicometric methods for testing of wood preservatives
2007 - IRG/WP 07-20354
The paper presents an outline of the history of forming standardized toxicometric methods for testing of wood preservatives in the world during last 100 years. Numerous studies resulted in three main methods which are currently used for official and basis assessment of biocides:
- agar-block method in Europe (EN 113);
- soil-block method in the USA and Pacific countries (ASTM D 1413);
- modifi...
J Wazny
Marine exposure assessment in southern Portugal of the natural resistance of a number of lesser known species of tropical hardwoods to teredinid and limnoriid borers
2007 - IRG/WP 07-10614
Naturally durable species of timber are used as an alternative to preservative treated timber for marine structures, but many species have not been evaluated for their potential for use in this environment. EN 275 specifies a 5-year test period - too long a period for screening tests to be economically viable. In this study, candidate timber species were selected for testing in the sea on the basi...
J R Williams, S M Cragg, L M S Borges, J D Icely, G S Sawyer
Accelerated Above-ground Testing of Wood Preservatives
2007 - IRG/WP 07-20358
The Canadian wood preservation industry is interested the introduction of new preservative formulations, some of which are intended only for above ground uses. Canada’s Pest Management Regulatory Agency requires data from field tests under Canadian conditions but these can take many years to generate results. Forintek has therefore developed an accelerated above ground test, under contract to a ...
P I Morris, S McFarling
Lyctine susceptibility testing and dealing with rarely susceptible hardwood species
2007 - IRG/WP 07-10607
This study examined the lyctine susceptibility of 16 timber species or hybrids. Several of the timbers have been placed previously in a ‘rarely susceptible’ category, but for standards and compliance purposes, such in-between ratings are not acceptable. Timber specimens were spot tested for starch content, and exposed to three species of lyctine beetles in an insectary. New criteria were devel...
L J Cookson, J Carr, N Chew, J W Creffield
Growth and succession of mould on commercial paint systems in two field sites
2007 - IRG/WP 07-30421
Discolouring fungi reduce the service life of coated wooden claddings in façades and increase the total cost of ownership due to shorter maintenance intervals. It is of major importance to find paint systems for wood which are durable and have a high resistance to mould growth. A total of 15 paint systems from 9 different manufacturers were exposed on two field sites, Sørkedalen and Birkenes, ...
L Ross Gobakken, K M Jenssen
Marine Borer Resistance of Modified Wood - Results from Seven Years in Field
2007 - IRG/WP 07-40375
Wood modified by several methods has been tested for seven years in a marine field with high marine borer activity. Several wood modification methods were included, e.g. thermal modification (with different processes), acetylation, maleoylation, succinylation, furfurylation, treatment with methylated melamine resin and modification with reactive linseed oil derivative. Furthermore, some combinatio...
M Westin, A O Rapp, T Nilsson
Durability of some alternatives to preservative-treated wood. Progress report 2: Results from field tests after 5 years’exposure
2007 - IRG/WP 07-30442
A number of alternatives to preservative-treated wood have been tested according to EN 252 (stake test) and a specially designed ground-proximity field test, the latter in Sweden as well as in Hawaii, USA. Seven untreated wood species and four alternative wood treatments labelled as environmentally friendly (acetylation, linseed oil, heat treatment, vinyl polymer) were included in the study. Four ...
M-L Edlund, J Jermer
Wood boring species present in the Tagus Estuary and the severity of their attack on wooden piles exposed in the area: a case study
2008 - IRG/WP 08-10664
Wood exposed in the marine environment is subject to degradation by wood boring organisms. This is probably one of the reasons why wood has been substituted by concrete and steel in maritime structures in many European coastal areas. Wooden piles obtained from a wharf exposed in the Tagus Estuary, Porto Brandão (Almada, Portugal) provided an opportunity to understand the main
agents of biodeter...
L M S Borges, L Nunes, A A Valente, P Palma
Variation of commercial timbers from Turkey in resistance to marine borers as assessed by marine trial and laboratory screening
2008 - IRG/WP 08-10668
Commercial timbers from Turkey used in coastal construction and boat building were tested for their resistance to marine wood-boring invertebrates in a marine trial and in a laboratory screening test. The timbers tested were beech (Fagus orientalis), oak (Quercus petraea), chestnut (Castanea sativa) and Scots pine (Pinus sylvestris). The marine trial was conducted over a period of 5 months at Mers...
H Sivrikaya, S M Cragg, L M S Borges
Validity of above ground testing according to ENV 12037
2008 - IRG/WP 08-20379
The standard ENV 12037 for testing of treated and untreated wood (lap-joint) exposed above ground
was issued in 1996 by The European Committee for Standardization. A draft for the development of the standard was presented by CEN-TC 38/WG 25/DOC N 076 in 2002. For a test to become valid the median rating of decay for untreated control replicates (Scots pine sapwood) must be equal or greater than ...
Ö Bergman, U Råberg, N Terziev
Development of a Weatherometer to Accelerate the Surface Checking of Wood
2008 - IRG/WP 08-20388
There is significant interest in developing preservatives that are better at preventing wood from checking. Currently, however, there is no accepted test methodology for accelerating the development of checks in wood samples so information on the effectiveness of treatments at restricting checking can be obtained more quickly. This paper describes the development of a new type of weatherometer (Ac...
R Ratu, P D Evans
Measurement of wood decay by dynamic MOE in an accelerated soil contact test
2008 - IRG/WP 08-20390
Current laboratory and field testing of preservatives involves various techniques to determine the extent of fungal attack, including visual inspection, mass loss, and static bending and compression strength measurements. The objective of this study was to compare decay measurement by conventional compression strength versus dynamic MOE, employing small wood stakes in an accelerated laboratory so...
Gan Li, D D Nicholas, T P Schultz