IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 44 documents. Displaying 25 entries per page.


Durability of Wood Plastic Composites Relative to Natural Weathering and Preservative Treatment With Zinc Borate
2005 - IRG/WP 05-40316
Wood-Plastic Composites (WPCs) used for decking have experienced dramatic increases in North America, averaging 25% growth per annum since 1998. A key factor contributing to this growth has been the successfully communicated message that they are "virtually maintenance free". The common perception being that the wood fiber is completely encapsulated by the thermoplastic resin, minimizing the pot...
M E Mankowski, F M Ascherl, M J Manning


ATP assay for the determination of mould activity on wood at different moisture conditions
1992 - IRG/WP 92-2397
To determine fungal responses to fungicides and environmental conditions and for detection of microbial activity in wood, sensitive and objective methods are needed. We have developed a suitable assay based on analysis of adenosine triphosphate (ATP) by using the luciferin-luciferase reaction. With the aid of this assay the activity of Penicillium brevicompactum on wood at different RH levels was ...
J Bjurman


Relative performance of copper/chrome/boron (CCB) and copper/chrome/arsenate (CCA) in ground contact
1992 - IRG/WP 92-3694
The performance of four retentions each of an oxide CCA formulation and a salt formulation of CCB in radiata pine and European beech was compared after 18 years' field exposure. In radiata pine CCA oxide was more effective (4 failures out of 40) than CCB (9 failures out of 40). However, in European beech CCB was substantially more effective (22 failures) than CCA oxide (all failed). Analy...
M E Hedley


L-joint trials: Part 3: Relative performance of a range of preservative products
2002 - IRG/WP 02-30292
Long-term trials using the L-joints described in BS EN 330 and AWPA Standard E9-97 have been in progress at BRE since 1982. This paper records the current assessments of decay of L-joints in trials started between 1982 and 1994 with treatments applied to both Scots pine sapwood (Pinus sylvestris) and spruce (Picea sp.). Data are provided on a range of active ingredients including TnBTO, PCP, a...
J K Carey


Relative tolerance of CCA by larvae and adults of the common shipworm, Bankia gouldi
1992 - IRG/WP 92-4174
Southern pine sapwood "2 x 4´s" were created by bolting together four panels 13 mm thick by 89 mm wide by 457 mm long. The two outer laminates were untreated and the two inner laminates were each treated to different CCA retentions, ranging from 8.0 to 43.2 kg/m³. Test specimens were exposed from May to October in a tributary of the Chesapeake Bay. Larvae were unable to settle on and burrow into...
B R Johnson


Methods of culturing Lyctidae
1980 - IRG/WP 1126
Members of the tropical countries in the IRG Sub-Group "Insects in dry wood" requested a paper on the breeding of lyctids. Compared with other wood boring insects, such as cerambycids and anobiids, the breeding of lyctids is not as difficult and time consuming. Nevertheless some basic principles have to be observed in the laboratory to obtain successful cu·ltures. It is the intention of this repo...
H Kühne


Relative merits of laboratory and field tests for assessing wood decay resistance
1993 - IRG/WP 93-20009
Laboratory and field trials have long been employed for assessing natural durability of a variety of wood species, but there is a continuing debate concerning the relative merits of approach. While laboratory tests provide carefully controlled conditions for decay, they are often criticized for being too artificial to produce meaningful results. Conversely, field trials often vary widely between t...
T C Scheffer, J J Morrell


Effect of humidity fluctuations on mould growth on pine wood
1989 - IRG/WP 1412
Most studies on mould development on wood material have been made at constant moisture conditions during the experimental period. As a consequence of such studies, a maximum permittable humidity level to avoid mould problems in wood constructions has been recommended. In the practical situation, the constructions are seldom subject to constant humidity or temperature. In the present paper, we repo...
J Bjurman


"Refractory" is a relative term. Incised alpine fir is treatable
1991 - IRG/WP 3670
While certain wood species carry a reputation for being 'treatable' this normally refers to the sapwood. For most Canadian species, heartwood penetration is the major determinant of whether treatment meets Canadian, USA and Japanese standards and in this respect alpine fir turns out to be a treatable species. Alpine fir is the fir component of the Western Canadian spruce-pine-fir...
P I Morris


A simple field apparatus for measuring relative gaff penetration and assessing the effect of additives for improving pole climbability
2000 - IRG/WP 00-20187
A simple apparatus for measuring and comparing the relative "hardness" of utility poles is described. This "slide-hammer" gaff penetration apparatus was designed as a field testing unit to measure the depth of gaff penetration into test poles after application of a uniform and reproducible force to the gaff. The apparatus is simple to use in both the laboratory and field. Data is provided for resu...
A R Zahora


Effect of humidity and temperature on fastener withdrawal resistance from CCA and ACZA treated Douglas-fir
2000 - IRG/WP 00-20209
The effects of preservative treatment on fastener withdrawal was investigated in Douglas-fir lumber conditioned to two moisture regimes. In general, conditioning samples to 19% moisture content produced more substantial changes in withdrawal resistance of galvanized fasteners than did conditioning to 12%. Treatment had little or no effect on withdrawal resistance of stainless steel fasteners. With...
Sung-Mo Kang, J J Morrell


Above Ground Field Testing – Influence of test method and location on the relative performance of various preservative systems
2008 - IRG/WP 08-20393
Standardized above ground tests such as the lap-joint or test deck methods can be very slow in producing useful information on the relative performance of wood preservative systems. It often requires many years for decay to develop in wood treated to sub-optimal concentrations of standardized preservatives, making relative comparisons of performance between new systems and established preservativ...
A Zahora


Evaluation of exposure conditions for wooden facades and decking
2009 - IRG/WP 09-20408
During their functional life, building components are exposed to moisture and other environment stress conditions in numerous ways. This is a fact that should be taken into account during manufacture, product development, designing and work execution of building components. For wood material, moisture stress and biological factors like mould and decay fungi are often critical in cladding and decki...
H Viitanen, T Toratti, R Peuhkuri, T Ojanen, L Makkonen


The Relative Performance of an Organic Preservative System under UC3A and UC3B Conditions using Two Test Methods
2010 - IRG/WP 10-20429
Coated L-joints have been used for decades to evaluate the performance of wood preservatives in protected environments. This study was conducted using matched coated and uncoated L-joints to simulate above ground protected and unprotect exposures. When exposed to constant moisture in a greenhouse environment, coated and uncoated L-joints give very similar performance results. In contrast, exposi...
C F Schauwecker, A Zahora, A F Preston


Laboratory Study of Relative Leachability of Chromated Copper Arsenate Preservative from Treated Woods among Soil Types of Sarawak
2014 - IRG/WP 14-50307
Wood and soils are important natural resources from the environment and serves mankind well respectively as structural materials and natural platform erecting such materials. With shortfalls of naturally durable timber species for protected in-ground uses under Malaysian environments, Chromated Copper Arsenate (CCA) treated woods are widely used instead, incurring serious potential threats of pres...
A H H Wong, P K F Chong


Real-Time PCR Assays for the detection of the dry rot fungus Serpula lacrymans and its close relative Serpula himantioides
2016 - IRG/WP 16-10867
Prevention of wood decay by fungi of the phylum Basidiomycota is an important issue of wood protection. The most destructive fungus in buildings in Central Europe is the dry rot fungus Serpula lacrymans, which needs more extensive restauration measures than all other wood decay fungi. Its close relative S. himantioides occurs more frequently in outdoor environment. The assessment and remediation o...
K Jacobs, N Rangno


Relative efficacy of various oxine copper formulations against brown-rot fungi
2019 - IRG/WP 19-30741
This paper investigates the relative resistance of three different oxine copper formulations (oil-borne, water-borne, water-borne with pH-adjustment) as a preservative treatment for wood against brown-rot fungi. Impregnated southern pine sapwood cubes were exposed to R. placenta and G. trabeum cultures in a soil-block test. After eight weeks, the weight losses of the cubes were examined in relatio...
M Petruch, J Lloyd, A Taylor


Joints design considerations in indoor high humidity conditions
2022 - IRG/WP 22-40950
In recent years, a number of cases of degradation by wood destroying fungi have been detected in covered timber structures such as pools, wineries, bathrooms, etc. – in fact, any building where indoor air may reach high humidity values during certain periods of time. The origin of this kind of decay was not related to water leaks, but to the condensation of the water vapor over the steel connec...
A Lozano, D Lorenzo, M Alonso, F Álvarez, J E Martínez


Eradication of beetles attacking wooden historical buildings by humidity-controlled warm-air treatment
2023 - IRG/WP 23-11028
Humidity-controlled warm-air treatment is a method that kills mainly beetles that are damaging the wood. In this process, a heat-insulating and airtight covering is placed around the object building, and the temperature inside the covering is gradually raised to about 60°C, held for a certain period of time, and then gradually lowered. While maintained at 60°C, all forms of damaging insects - ad...
Y Fujii, Y Fujiwara, M Harada, H Kitahara, M Shimada, S Kondo, Y Sato, M Shimada, R Kigawa, H Watanabe, Y Komine, S Hidaka, D Ogura


Previous Page