Screening techniques for potential wood preservative chemicals. Proceedings of a special seminar held in association with the 10th Annual Meeting of the IRG, Peebles 1978. Report No 136, 1979
1980 - IRG/WP 2138
This paper continues following issues: I. SCREENING INSECTICIDES 1) R W Berry (BRE/PRL, UK): Screen testing of insecticides for use in remedial wood preservatives. 2) D J Cross (FRI, New Zealand): Rapid screening of contact insecticides for use on forest products. 3) C R Coggins; A Forsyth; A E Glaser (Rentokil, UK): Experience in the use of indicative screening techniques for termiticides. ...
Anonymous


Laboratory evaluation of six commercial termiticides against subterranean termite, Coptotermes gestroi Wasmann
1994 - IRG/WP 94-30034
Small specimens of Heavea brasiliensis (10 x 10 x 20 mm³) were exposed to the laboratory colony of Coptotermes gestroi Wasmann for 4 months after dip- or brush-treatment with six commercially available emulsifiable termiticides (alpha-cypermethrin, cypermethrin, permethrin, bifenthrin, chlorpyrifos and chlordane). Synthetic pyrethroids and chlorpyrifos were effective as well as 1% treatment of ch...
Y Sornnuwat, C Vongkaluang, T Yoshimura, K Tsunoda, M Takahashi


Soil termiticides: A review of efficacy data from field tests
1987 - IRG/WP 1323
This paper reports efficacy data from the field evaluation of various soil termiticides by the U.S. Department of Agriculture, Forest Service, Gulfport, Mississippi. These chemicals, which include a number of chlorinated hydrocarbon, organophosphate, pyrethroid, and carbamate insecticides in a range of concentrations, have been in long-term tests at seven field sites. Data are reported for the gro...
J K Mauldin, S C Jones, R H Beal


Sulfluramid, a new bait concept for the control of termites
1995 - IRG/WP 95-30075
The annual cost of preventing, controlling and repairing the damage done by termites in the United States of America is in the billions of dollars. Current termite control methodology is generally effective in the control of termite activity. However, new technology (termite foams, termite baits, physical barriers) is emerging which has or will provide new tools to control termites. This report ce...
J B Ballard, T K Porter


Accelerated termicidal performance data for new water-based copper linoleate formulations
1996 - IRG/WP 96-30104
An organic solvent based copper linoleate (Culin) has proved itself as an effective wood preservative in long term field trials in South Africa over a period of 30 years. Whilst the organic solvent based product offers good wood preservative performance, primary industrial interest has been in an emulsified version of the product. The objective of this study was to evaluate the influence of two di...
D Conradie, P Turner


Standard principles of testing termiticides: A discussion paper
1991 - IRG/WP 1502
Recent restrictions and banning of termiticides such as organochlorines in some countries has focussed attention on the need for new and novel compounds as termiticides. However, this poses problems for both wood preservative manufacturers and termitologists. Test procedures have to be devised to evaluate the new termiticides so that the tests are practical, encourage vigorous termite activity, an...
J R J French


Special seminar on screening techniques for potential wood preservative chemicals
1978 - IRG/WP 2113
This paper continues following issues: I. SCREENING INSECTICIDES 1) R W Berry (BRE/PRL, UK): Screen testing of insecticides for use in remedial wood preservatives. 2) D J Cross (FRI, New Zealand): Rapid screening of contact insecticides for use on forest products. 3) C R Coggins; A Forsyth; A E Glaser (Rentokil, UK): Experience in the use of indicative screening techniques for termiticides. ...
Anonymous


Termiticide degradation in Mississippi field tests
1994 - IRG/WP 94-30052
Degradation rates of some currently marketed United States termiticides are currently being studied. Separate quantities of soil were each treated at lowest label rates with termiticide, and placed in trenches along the inside and outside of concrete walls. Composite soil samples, each consisting of four soil cores, were collected after 1, 30, 60, 120, 180, 240, and 365 days, and again at 2 and 3 ...
B M Kard


A novel chemical barrier system, KORDON® TMB, for the protection of buildings against subterranean termites using a synthetic matrix as carrier for the chemical
1998 - IRG/WP 98-10264
Kordon TMB is a new chemical barrier system for installation beneath concrete slab-on-ground constructions using a matrix other than soil as carrier for the termiticide. The product consists of a synthetic foraminous web (blanket) carrying the synthetic pyrethroid deltamethrin. The blanket is laminated on the upper side to a standard 0.2mm thick moisture vapour membrane of low density polyethylene...
M Lenz, P Morrow, S Runko


A case for ecosystem-level experimentation - A discussion paper
1986 - IRG/WP 1296
Although laboratory bioassays provide a first step in testing for potential termiticides and assist in formulating recommendations of these chemicals for regulatory agencies and users, they are not designed for predicting effects on natural populations (including humans) and on ecosystem-level features. To overcome this we need microcosm studies, carefully controlled experimental manipulations of ...
J R J French


Comparison of permethrin and fenvalerate as termiticides and their significance to Australian Quarantine Regulations
1984 - IRG/WP 1230
This paper reports detailed laboratory evaluations of the termiticidal efficacy of permethrin and fenvalerate-treated wood blocks. Comparison between artificially wheathered permethrin-treated blocks and unweathered blocks is given. The effect of a 6-week soil burial period on pyrethroid-treated blocks at a retention of 0.08 kg/m³ is also reported. Toxic or protection threshold values for the two...
J W Creffield, C D Howick


Laboratory method for testing the effectiveness of soil termiticides
1992 - IRG/WP 92-1561
In France, the protection of buildings against termites is based on a chemical treatment of wood, soil and walls. Because of the withdrawal of aldrin from the market, the need of new soil termiticides has appeared. Therefore, a laboratory method derived from Cymorek's method has been developped to assess their effectiveness. Some points are developed like the type of soil, the number of t...
M-M Serment, A-M Pruvost


Persistence and residual activity of organophosphorus termiticides in soil and prevention against the degradation of chlorpyrifos
1991 - IRG/WP 1518
The persistence and the residual activity of four comercial organophosphorous termiticides, Chlorpyrifos, Fenitrothion, Tetrachlorvinphos, Pyridaphenthion, in soil were studied under laboratory conditions. The persistence and the residual activity of four organophosphorous termiticides in two types of soil decreased with the lapse of time. These termiticides were mostly degraded by microorganisms ...
T Iijima, M Tanaka, M Higaki


Deltamethrin effectiveness against subterranean termite attack on wood under natural conditions
1989 - IRG/WP 1407
On fighting subterranean termites on wood, out of ground contact, the synthetic pyrethroid Deltamethrin shows positive aspects such as its efficiency and low mammalian toxicity. To evaluate its performance in conditions very similar to those in service use, specimens of Pinus sp were treated with solutions of Deltamethrin diluted in "white spirits" at 0.005% (w/w) and 0.01% (w/w) and exposed in a ...
P A Zanotto


Efficacy of termiticide treatments to soil in field tests in the southern United States
1994 - IRG/WP 94-30043
In standard ground-board and concrete-slab efficacy tests in the southern United States, termiticides provide several years of subterranean termite control depending on rates applied to the soil and test site location. Years of 100% control (as of February 1994) provided by each currently marketed termiticide applied at highest label rates under concrete slabs in our four primary test sites (Flori...
B M Kard, J K Mauldin


Practical considerations of the Formosan subterranean termite in Louisiana: A 50-year-old problem
2000 - IRG/WP 00-10330
In an eleven-year censusing (1989 through 1999) in the French Quarter of New Orleans and surrounding areas, Coptotermes formosanus alate numbers were found to be increasing dramatically in all years but one. Moreover, in parks and neighborhoods in New Orleans and Lake Charles, LA, as well as in Sam Houston Jones State Park near Lake Charles surveyed in 1998, alarmingly high numbers of this exotic ...
G Henderson


Future termite control requires partnership between industry, government and people
2006 - IRG/WP 06-10586
Given the behaviour of the pest control industry, together with the housing and timber industries, and performance of the State regulatory agencies, it is not surprising that all of these groups were philosophically ill-prepared to consider alternative measures in June 1995. However, conditions have altered and there is an awareness of such alternatives. In future, termiticides will have propertie...
J R J French, B M Ahmed


Accelerated assessment tests of new termiticides
2007 - IRG/WP 07-20353
One of the biological agents, which cause major damage to wood in Spain, is the subterranean termites. The systems used for controlling termites don’t eradicate them, and the products presently used to treat wood against them, due to their toxicity and their persistence in the environment, could be prohibited in the near future in Europe as consequence of the 98/8/EC Directive (usually called t...
M T Troya, M J Prieto, D Lorenzo, F Rubio


Comparison of laboratory termite test methods
2007 - IRG/WP 07-20365
Seven standardized laboratory tests with termites were evaluated. The bioassays were made in accordance with EN 117, SAA32 E08, SAA32 E09, Ebw 02, the American Wood-Preservers’ Association (AWPA) Standard E1-97, the Japan Wood Preserving Association (JWPA) Standard 11 (1) and The Protocols for Assessment of Wood Preservatives. Two different wood preservatives each in three concentrations and add...
H-U Kruschinski, W Unger, A F Preston


Long-time efficacy of some soil termiticides tested according to “Modified Ground Board Test”
2018 - IRG/WP 18-10935
Field trials of efficacy of soil termiticides available in Thailand were started back in the 1980s at four different locations representing different unique weather types of the country. The method used in the trials (Modified Ground Board Test) is the compulsory test for every soil termiticides aiming to be registered for termite control in Thailand. The ongoing record reveals that some particula...
C Vongkaluang, K Charoenkrung, N Same Rain


Preserved Wood in the Story of Sustainable Forestry
2018 - IRG/WP 18-50344
Sustainable forestry, at its simplest, is about growing trees. The full story, though, is much more complex. An important chapter of that story is the role that preserved wood plays in ensuring sustainability. Too often, this part of the sustainability story is rarely mentioned. It is time for the preserved wood industry to deliver a unified message of our critical role in sustainability. By res...
D Brookes