IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 373 documents. Displaying 25 entries per page.


Impact of sapwood portions on the durability of adjacent heartwood of Pinus sylvestris, Pseudotsuga menziesii and Quercus robur. Part 1: Laboratory studies
2018 - IRG/WP 18-10922
Sapwood is generally considered as non-durable and assigned to durability class DC 5 according to European standards independent from the wood species. It is commonly agreed that sapwood decays faster than adjacent heartwood, but it is controversially discussed whether sapwood serves as feeder material and thus accelerates onset and progress of decay in more durable heartwood or decays independent...
C Brischke, P Homann, A Gellerich


Interaction of Boultonizing and through-boring of Douglas fir sapwood
2018 - IRG/WP 18-40833
The interaction of combining through-boring and Boultonizing treatment effects on strength properties was investigated. Small, clear Douglas fir beams were through-bored and/or Boultonized in full factorial design and evaluated for toughness, MOE and MOR. The simulated through-boring treatment lowered the mechanical properties but the Boultonizing process did not. There was also no evidence for a ...
F Gasteiger, J Lloyd, A Taylor


Effect of damage to polyurea coatings on metal losses from ammoniacal copper zinc arsenate treated Douglas-fir pile sections
2019 - IRG/WP 19-40867
Metal-based preservatives remain the most widely used treatments for protecting wood in soil or water contact. While these treatments are highly effective, one drawback is a tendency for small amounts of metal to migrate into the surrounding environment. The greatest risk in this regard is copper because many organisms are highly sensitive to this metal. While post treatment practices can reduce ...
M J Konkler, J J Morrell


Sterilization of Large Timbers during Preservative Treatment: How Quickly We Forget
2020 - IRG/WP 20-40902
Air seasoning is a common method of moisture management in utility poles and is done de facto during pole storage prior to treatment. However, extended air drying prior to treatment encourages fungal attack and can facilitate establishment of decay fungi in poles before a protective preservative barrier is applied. This problem can be mitigated by proper air-seasoning methods coupled with heat ste...
G Presley, J Cappellazzi, M Konkler, K Maguire, R Nelson, J J Morrell


Studies on the material resistance and moisture dynamics of Douglas fir and Sitka spruce from Slovenia
2021 - IRG/WP 21-20677
Wood in outdoor applications is subject to various decomposition factors. Wood degradation can be prevented by construction details, biocide protection of wood, wood modification, or selection of naturally durable wood species. Unfortunately, the majority of timber species in Europe do not have naturally durable wood. Imported tree species represent a new pool from which we can draw wood species w...
M Humar, B Lesar, D Krzisnik, E Kerzic, R Brus


Durability of fast- and slow-grown Douglas fir in above ground exposures in Australia
2023 - IRG/WP 23-11009
Natural durability is a key property for untreated timber used outdoors and exposed to the weather. The natural durability of fast- and slow-grown Douglas fir heartwood was compared in an above-ground L-joint field test near Brisbane, Queensland, Australia. The L-joint test provides conditions that are favourable to decay. Fast-grown (regrowth) Douglas fir had ≤ 10 growth rings per 50 mm, while ...
L P Francis


Performance of Douglas-fir cross laminated timber (CLT) subjected to elevated humidity in a ground proximity field test for 6 years
2024 - IRG/WP 24-41010
The ability of insecticidal soil drenches or spray-on insecticide/fungicide treatments to protect mass timber elements exposed in a high moisture environment but out of direct soil contact was assessed using a modified AWPA ground proximity test established in 2017. Three-ply Douglas-fir CLT pieces measuring 305 x 355 x 105 mm (L x H x W) were installed at the Harrison Experimental Forest (HEF) (S...
M E Mankowski, J J Morrell, T G Shelton, G T Kirker


Copper migration from preservative-treated Douglas-fir decking: models vs laboratory leaching data
2024 - IRG/WP 24-50390
The ability of a model to predict copper migration from Douglas-fir treated with organic metallic substances into a freshwater slough was evaluated against data generated through simulated overhead leaching. The model predicted very high loadings of ammoniacal copper zinc arsenate, alkaline copper quaternary or copper azole that had the potential to impact water quality while data from the exper...
M J Konkler, G Presley, J J Morrell, T Singh


Field trial with poles of Scots pine treated with six different creosotes
1996 - IRG/WP 96-30115
In the middle of the 50's field trials with creosote-treated poles were started in France, Germany and Sweden. The trials were initiated by WEI (Western-European Institute for Wood Preservation). Six different creosotes were used and 40 poles per creosote were installed at each test field. Results after 39 years of exposure in Simlangsdalen, Sweden are reported. Poles treated with a heavy...
Ö Bergman


Soft rot in CCA-treated utility poles in Sweden
1989 - IRG/WP 1398
Soft rot investigations of CCA-treated utility poles (Pinus sylvestris L.) have been conducted throughout large parts of Sweden during 1974-1985. The investigation included 179 utility poles of the State Power Board which had been used for 10-18 years in the different administrative regions from northern to southern Sweden. In addition, 193 telephone poles from the Östersund area and 218 from the...
H Friis-Hansen, H Lundström


Soft rot penetration - Effect of groundline maintenance treatment on poles in sevice
1983 - IRG/WP 3263
R S Johnstone


Progress towards controlling soft rot of treated hardwood poles in Australia
1977 - IRG/WP 289
H Greaves


Essais biologiques sur poteaux traités à la Wolmanit C.B. suivant le procédé Boucherie modifé
1974 - IRG/WP 336
D Lapetite, C Jacquiot, J Campredon


A case study on quality control on telephone poles as a cost saving tool in Tanzania
1987 - IRG/WP 3418
A sample of 28 CCA treated Eucalyptus poles from a lot of 2,000 poles awaiting delivery to the field, was studied to reveal the quality of treatment. Results showed a product of very poor quality. Average figures for penetration and retention were 8.4 mm and 2.2 kg/m³; these results are 66% and 91% below the required standards, respectively. Consequences of such results are estimated to amount to...
K K Murira


Extending the useful life of creosoted electricity distribution poles in service
1993 - IRG/WP 93-50001-16
Creosoted transmission poles have provided good service over many decades in a whole range of environments. The use of save biocides for secondary treatments has the potential to extend the life of such poles. These techniques, together with a full understanding of the modes of failure, make it possible to establish new strategies to further improve the environmental benefits of treated wooden pol...
D J Dickinson, B Calver


Effectiveness of "Gang-Nail" plates in preventing splitting of Eucalyptus poles and Brazilian hardwood sleepers
1984 - IRG/WP 3262
This paper presents the results of some tests carried out with an anti-splitting device, placed on the end surfaces of Eucalyptus spp utility poles and Brazilian hardwood sleepers at the beginning of an air-drying period. The type of device used, a "Gang-Nail" plate, reduces significantly the splits at the end-surface of poles, but reduces only a little the splits occurring in sleepers....
A M F Oliveira, J A C Sodré, O B Neto


Field trials of groundline remedial treatments on soft rot attacked CCA treated Eucalyptus poles
1983 - IRG/WP 3222
A total of 17 CCA treated Eucalyptus poles, which were found to contain 2-5 mm of soft rot in October, 1980, were reinspected in October, 1982. In 1980, 11 of the poles were given a supplemental groundline bandage treatment of either Osmoplastic or Patox, while 6 of the poles were designated as untreated controls. Two years after remedial treatment, samples were removed from the poles for microsco...
W S McNamara, R J Ziobro, J F Triana


Cu, Cr and As distribution in soils adjacent to CCA treated utility poles in Eastern Black Sea Region of Turkey
2004 - IRG/WP 04-50214
In this study, the main objective was to asses the distribution of Cu, Cr, and As in soils adjacent to CCA treated utility poles in Eastern Blacksea Region of Turkey (Trabzon, Rize and Artvin ) and determine the influence of soil composition. Surface (0-5cm), subsurface soil samples (30-40cm) were collected near CCA-treated utility poles and control soil samples away from CCA-treated utility pole...
E D Gezer, Ü C Yildiz, A Temiz, S Yildiz, E Dizman


Gloeophyllum trabeum and Gloeophyllum abietinum, the most frequent brown rot fungi in fir wood joinery
1999 - IRG/WP 99-10319
In Croatia the primary raw material for joinery production is silver fir wood (Abies alba Mill). L-joints made of home-grown fir sapwood and prepared according to EN 330: 1993 were used to establish the infection and colonisation of micro-organisms, particularly wood decay fungi, to compare the performance of untreated and 1% TnBTO treated L-joints. The L-joints were coated with two types of coat,...
R Despot, M Glavas


Introduction to a field demonstration of various instruments and methods for the detection of defects in poles
1984 - IRG/WP 2228
H Friis-Hansen


Essais mycologiques sur poteaux traités à la Wolmanit C B
1974 - IRG/WP 339
D Ollier, C Jacquiot


The leaching of copper, chrome and arsenate from CCA-impregnated poles stored for ten years in running water
1978 - IRG/WP 3122
There is no evidence to indicate that the chromium and copper components are leached from the outermost 5 mm of sapwood in poles impregnated with Boliden K33 and Tanalith C and stored in running water for ten years. The arsenic component, however, seems to be leached out during the first few months to an extent of about 20% of the initial amount. The leaching time is dependent on the preservative ...
F G Evans


Japanese wood preserving industry
1990 - IRG/WP 3596
Although a great amount of wood is in use in Japan, a little attention has been paid to the significance and importance of wood preservation. The fact reflects that only less than 0.5% of the total wood consumption is treated with wood preservatives today in the country. Over the 20 years before 1970, the annual volume of preservative treated (pressure treatment) wood was relatively at a stable le...
K Tsunoda


Decay resistance of wood removed from poles treated with Trichoderma
1989 - IRG/WP 1386
Wood blocks removed from a distribution pole previously treated with a biological control product (Binab FYT pellets) were exposed in soil block tests to selected basidiomycetes. The blocks were removed from regions of poles where Trichoderma colonization had been confirmed by extensive sampling and computer mapping of microbial inhabitants. The results indicate that material from pole interiors c...
A Bruce, B King, T L Highley


Untersuchungen über die Imprägnierbarkeit verschiedener türkischer Holzarten mit wirtschaftlicher Bedeutung
1976 - IRG/WP 370
Holzarten mit einer geringen natürlichen Dauerhaftigkeit können nur dann wirtschaftlich verwendet werden, wenn ihre Gebrauchsdauer durch einen zusätzlichen chemischen Schutz verlängert wird. Holzschutzmaßnahmen können nur regelmäßig geplant werden, wenn die Tränkbarkeit der verwendeten Holzarten bekannt ist. Aufgabe dieser Versuche war es daher, festzustellen, wieweit die Holzarten hinrei...
R Ilhan


Previous Page | Next Page