IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 280 documents. Displaying 25 entries per page.


Performance of untreated French Guianan piling in marine exposure
1992 - IRG/WP 92-4173
Round piling of seven French Guianan species, greenheart, and preservativ-treated Southern Pine were installed as fender piling in Key West, FL. After 12½ years, none of the tropical hardwoods performed as well as dual-treated Southern Pine. Of the hardwoods, kouata patou and maho noir were the most resistant to decay and marine borers....
B R Johnson


Natural resistance of twenty-six Guianese wood species against marine borers
1988 - IRG/WP 4144
This note is a contribution on the study of the natural resistance of some wood species from French Guiana, some of which could be found too in the neighbourhood. Here are presented the results after one year exposure in the marine environment....
L N Trong


Protection for whole-of-house timbers from subterranean termites in Australia
2005 - IRG/WP 05-20315
A field study was designed to increase maximum protection of whole-of-house timbers against subterranean termites. Concrete slab and suspended floor simulated houses were constructed using untreated and treated (slow acting toxicants) timber frames. The treated and untreated timber structures within the simulated houses were exposed with or without soil chemical and/or physical barriers in the fie...
B M Ahmed, J R J French, P Vinden, P Blackwell, J Hann


Errata in Document NO: IRG/WP/472
1981 - IRG/WP 483
L N Santhakumaran, J C Jain


Finishes for outdoor timbers
1975 - IRG/WP 378
Anonymous


Granitgard used as a partial and perimeter barrier in the protection of buildings against subterranean termites
1995 - IRG/WP 95-10114
The graded granite subterranean termite physical barrier, commercially marketed as Granitgard, has a Certificate of National Accreditation issued by the Australian Building Codes Board, and is included in Australian Standards. After several years in developing the specifications and installation techniques for Granitgard, it may be used to protect almost all footing designs. Granitgard can be simp...
D M Ewart, J R J French


Penichroa fasciata (Stephens) (Col. Cerambycidae) a pest in wood materials
1988 - IRG/WP 1365
Penichroa fasciata (Stephens) (Col. Cerambycidae) is found to be a frequent pest occurring in hardwood in storage in Italy. This paper reports the characteristic for identification, biological features, distribution and timber liable to attack....
A Gambetta, E Orlandi.


Fungal and bacterial attack of CCA-treated Pinus radiata timbers from a water-cooling tower
1991 - IRG/WP 1488
Transmission electron microscopy of decaying CCA-treated Pinus radiata timbers from an industrial water cooling tower showed presence of a thick biofilm covering some areas of the wood. The biofilm contained various morphologically distinct forms of microorganisms embedded in a slime. The study provided evidence of the activity of soft rot fungi and tunnelling and erosion bacteria in wood cells. T...
A P Singh, M E Hedley, D R Page, C S Han, K Atisongkroh


International collaborative laboratory comparison of two wood preservatives against subterranean termites: Third update and first report
1996 - IRG/WP 96-10174
At the 24th annual meeting of IRG in Orlando, USA, in May 1993 an international subterranean termite laboratory bioassay to compare the various preferred termite protocols used by IRG termitologists was initiated. The author was nominated to co-ordinate this comparative laboratory evaluation of two wood preservatives, copper-chrome-arsenic (CCA) and copper naphthenate (Cu-Na) against the subterran...
J R J French


Comité International Permanent pour la Recherche sur la Préservation des Matériaux en Milieu Marin. Information from the Wood Group
1980 - IRG/WP 460
E G B Jones


Report on the monographic card on Coniophora puteana
1973 - IRG/WP 114
A Käärik


Report and recommendations of the National Termite Workshop held in Melbourne on the 17 April 2002.
2003 - IRG/WP 03-10478
There are two parts to this Report. Part One summaries the outcomes of an industry workshop organised to better scope the subterranean termite problem, identify knowledge gaps including R&D gaps and identifying strategies including cost-effective co-ordination mechanisms for addressing the issue. Part Two is a brief review of the current state of knowledge on subterranean termites of economic ...
B M Ahmed, J R J French


Termite standards questionnaire survey. Second Report
1989 - IRG/WP 1395
Information contained in replies received from IRG members responding to the survey continue to be summarised. Again, highlighted in this second report are the major termite species in the various zoogeographical regions, their damage ranking to timber-in-service, the chemicals used in control methods, and the status of the termite standards in the respondent countries....
J R J French, J P La Fage


Natural durability transfer from sawmill residues of white cypress (Callitris glaucophylla). - Part 3: Full penetration of the refractory sapwood of white cypress
2000 - IRG/WP 00-40167
The heartwood of white cypress, Callitris glaucophylla, is renowned for its termite resistance and durability against decay. The sapwood, which can represent up to 30% of log volume, is non-durable and refractory to conventional preservative treatment. Previous work ascribes the lack of permeability to oily deposits within tracheids and ray cells. Environmental scanning electron microscopy was use...
M J Kennedy, L M Stephens, M A Powell


Physical barriers and bait toxicants: The Romeo and Juliet of future termite control
1991 - IRG/WP 1503
Soil chemical barriers are considered by some to be the most important technique for protecting buildings against subterranean termites in Australia (and elsewhere), providing a barrier against termite penetration. However, there is no such thing as a barrier that is 100 per cent +protective. And given the worldwide problems of using organochlorine termiticides, public awareness of chemical pollut...
J R J French


Problem of the treatment of dried sawn spruce building timbers with water-borne preservatives. Interim reports for discussion at the 4th Annual Meeting in West Berlin on 27 October 1972
1972 - IRG/WP 311
One of the most difficult technical problems facing the preservation industry is how to improve the treatment of refractory species of timber such as spruce. Its resistance to penetration, even under pressure' precludes its use for more hazardous service situations, and even in less severe conditions a higher level of treatment would be desirable. The importance of this subject led us to ...
W Liese, J W W Morgan, T Hof, R O Ullevålseter


Successive collections of Basidiospores from wood decay fungi (in vitro) show variation in germination levels on common media
1978 - IRG/WP 191
In the course of various preliminary experiments in which spore germination levels of 6 decay fungi on malt and water agar were recorded as controls, it was noted that one could not reliably obtain an expected level of spore germination for any particular fungus. Inconsistent 'control' spore germination levels of a fungus greatly complicates large scale experiments in which compa...
E L Schmidt, D W French


IRG/COIPM INTERNATIONAL MARINE TEST - to determine the effect of timber substrate on the effectiveness of water-borne salt preservatives in sea-water. Progress Report 10 from Naos Island, Panama
1980 - IRG/WP 462
Blocks of 3 wood species, Beech (Fagus sylvatica), Scots pine (Pinus sylvestris) and Alstonia (Alstonia scholaris) were exposed at site number 12 at Naos Island, Panama on March 8, 1978 by John R. DePalma. The arrangement of the panels in the exposure site is as shown in Figure 1....
D W French


Monographic information on Lentinus lepideus.markup
1973 - IRG/WP 121
G Seehann, W Liese


Spore germination of Gloeophyllum trabeum on wood is related to the mass of the wood sample
1978 - IRG/WP 2118
E L Schmidt, D W French


The susceptibility of 35 Amazon wood species to Cryptotermes brevis (Walker)
1982 - IRG/WP 1160
Laboratory tests were carried to evaluate the susceptibility of 35 Amazon hardwoods to Cryptotermes brevis (Walker). The results were analysed statistically and showed that five wood species were non resistant, nine were resistant and the other twenty-one in between those classes of resistance....
M D Canedo


Some observations on Chlorophora pilosus Forst. var. glabromaculatus Goeze (Coleoptera, Cerambycidae)
1980 - IRG/WP 1119
A Gambetta


The biostatic effect of copper on decay of fire retardant-treated mining timber
1991 - IRG/WP 1507
Blocks of Eucalyptus grandis were treated with 20kg/m³ ammonium sulphate as fire retardant and challenged with Coriolus versicolor. Replicates were soil buried. A second set of blocks was treated with retardant and copper at 6.6 kg/m³ (ie 1% w/w), and challenged similarly. After 8 weeks weight losses produced by Coriolus versicolor in untreated, retardant treated and copper supplemented blocks w...
G D Shelver, E A Shelver, A A W Baecker


Feeding preference behaviour of Crytopermes cynocephalus Light and Coptotermes curvignathus Holmgren on twenty-eight tropical timbers
1985 - IRG/WP 1251
A study on the feeding preference behaviour of a dry-wood termite Cryptotermes cynocephalus Light and a subterranean termite Coptotermes curvignathus Holmgren on 28 species of tropical timbers has been conducted. The weight-loss of individual timber and the mortality of termite was·recorded after 5, 10, 15, 20 and 25 days of exposure. The results reveal that there are only five species among 28 s...
Nana Supriana


A method for screening termite baits using Coptotermes lacteus mounds
1984 - IRG/WP 1237
A method with several variations designed to rapidly screen potential bait substrates using Coptotermes lacteus mounds is described. The equipment used in this method is relatively inexpensive, readily prepared in the laboratory, and easily installed into active mounds in the field. Bait substrates are in continuous contact with a 'high termite hazard', and may be monitored with ...
J R J French, P J Robinson