A collaborative test to determine the efficacy of polyurethane coatings on wood samples exposed in the marine environment
1984 - IRG/WP 4113
Aims are: a) to determine the effectiveness of elastomeric polyurethane as a protective coating against marine wood boring animals in a range of tropical and tempreate sites; b) to compare the adhesion of polyurthane coatings on different wood species exposed in seawater; c) to record the severity of attack in failed samples and to identify the causal marine organisms....
R A Eaton
A survey to assess the current and future usage of timber in British port structures
1998 - IRG/WP 98-10247
Port engineers responsible for 30 British ports were surveyed by questionnaire or interview to establish current and prospective usage of timber in those ports. The ports surveyed account for about 25% of total cargo handled annually in Britain and being located all around the British mainland, were considered to form a representative sample. The survey identified the hardwoods and softwoods in us...
G S Sawyer, S E M Plaster
The effectiveness test of chemicals against Serpula lacrymans
1984 - IRG/WP 2222
The effectiveness tests of wood preservatives against Serpula lacrymans were conducted in accordance with Japan Industrial Standard A 9302 and Japanese Wood Preserving Association Standard No. 1. Also, the soil treatment test against this fungus was carried out with two chemicals. The preservatives tested without Creosote oil (out of JIS) had sufficient preservative effect against Serpula lacryman...
S Doi
Testing of termiticides in soil by a new laboratory method with regard to Phoxim for replacement of chlorinated hydrocarbons
1986 - IRG/WP 1292
In comparison to chlorinated hydrocarbons insecticides of the compound classes organophosphates, carbamates and pyrethroids were tested according to an earlier described soil-test in the laboratory. The following termite-species were used: Heterotermes indicola, Reticulitermes santonensis and in addition Reticulitermes flavipes, Reticulitermes lucifugus, Reticulitermes speratus and Coptotermes for...
R Pospischil
Above ground performance of CCA-treated fingerjointed lumbe
1993 - IRG/WP 93-40003
Studs made from short lengths by finger jointing are becoming more commonly used in North America. Recently Forintek has received enquiries about the performance of such material in a treated form. Treated and untreated nominal 2x4 inch² spruce-pine-fir (SPF) studs exposed above ground for 12 years in southwestern British Columbia were evaluated for evidence of decay. Despite shallow preservative...
P I Morris, G E Troughton
Testing of alkylammonium compounds
1981 - IRG/WP 2152
Following laboratory soil block tests which showed that Bardac 20 possessed a fungicidal threshold similar to that of chromated copper arsenate, treated ponderosa pine sapwood stakes were installed in a field test site near Vancouver, Canada. Two years after installation all the stakes show signs of fungal degradation. Seven stakes have been removed from the test due to total loss of strength afte...
J N R Ruddick
Report of the meetings of the Refractory Timbers Sub-group, Rotorua, New Zealand, 15 & 17 May 1990
1990 - IRG/WP 3637
R J Murphy
Collaborative soft rot tests: Summary of comments on 'Proposals for a standardized soil burial test'
1971 - IRG/WP 202
J G Savory
A standardised procedure for the treatment of timber with test chemicals
1986 - IRG/WP 2257
A procedure is described which allows the standardisation of sample handling and data manipulation during trials invastigating the treatability of timber with test chemicals. The use of computer software allows the data to be handled efficiently....
J Norton, A Zosars, L E Leightley
Natural resistance of twenty-six Guianese wood species against marine borers
1988 - IRG/WP 4144
This note is a contribution on the study of the natural resistance of some wood species from French Guiana, some of which could be found too in the neighbourhood. Here are presented the results after one year exposure in the marine environment....
L N Trong
Draft Business Plan of CEN/TC 38 - Durability of wood and wood-based products - Introduction
2000 - IRG/WP 00-20207
CEN Technical Committees and Business Planning. The extension of formal business planning to CEN Technical Committees (CEN/TCs) is an important measure which forms part of a major review of business processes (known as 'Optimization'). The aim is to align the CEN work programme with expressed market needs and to ensure the adequate resourcing of projects through their development...
R Hüe
Austrian field test method for anti-sapstain chemicals
1994 - IRG/WP 94-20020
Although Austria is a small country, the annual consumption of anti-sapstain products ranks to approximately 500 tons annually. In 1994, only three products will be approved by the Austrian Wood Preservation Committee (AWPEC). There is demand for a field test method, which demonstrates the efficacy of an anti-sapstain product and consequently implies the acceptance and approval of product by the A...
R Gründlinger, M Brandstätter, H Melzer, O Janotta
Exterior weathering trials on radiata pine roofing shingles
1985 - IRG/WP 3240
A series of test roofs clad with radiata pine (Pinus radiata D. Don) shingles that had been pressure-treated with various water-borne preservative formulations were installed at a Forest Research Institute test site in Rotorua in 1977. A further series of test roofs installed in 1978 included radiata pine shingles pressure-treated with a commercial light organic solvent preservative (LOSP). Evalua...
D V Plackett, C M Chittenden, A F Preston
Performance of surface-treated hardwoods and softwoods out of ground contact
1990 - IRG/WP 3592
A number of fungicides were tested as brush treatments for protection of southern pine, Douglas-fir, maple, and red oak against decay above ground. Cross-brace and L-joint test units were treated just before assembly and exposed from 3-10 years. Untreated Douglas-fir cross-brace units were not decayed at either the Mississippi or Madison, WI, site. Untreated red oak cross-brace units were not deca...
T L Highley
Baiting techniques for subterranean termite control
1983 - IRG/WP 1205
The use of artificial baits, with and without toxins, have proved effective in attracting large numbers of non-mound and mound building subterranean termites in both urban and rural areas. An outline is presented of a termite baiting program which emphasises concurrent laboratory and field investigations on termite ecology, behaviour and physiology...
J R J French, J P Robinson
Preventive action against fungal decay: A comparative experiment on the effects of natural and artificial infection of wood by Basidiomycetes
1981 - IRG/WP 2160
M Fougerousse
Proposed test procedure to determine the effect of timber substrate on the effectiveness of a copper/chrome/arsenic preservative in seawater
1975 - IRG/WP 411
R A Eaton
IRG test of preservative-treated hardwoods with particular reference to soft rot. Report on condition of specimens installed in Victoria, Australia
1983 - IRG/WP 3269
G C Johnson, J D Thornton
IRG WG III - World-wide co-operative field experiment
1977 - IRG/WP 383
R Cockcroft
Comparative performance of pentachlorophenol and copper naphthenate in a long term field stake test
2000 - IRG/WP 00-30243
In this study the performance of copper naphthenate (Cu-Nap) and pentachlorophenol (Penta) treated pine stakes against decay and termite attack were compared at two test sites in Mississippi. Four different petroleum oils meeting AWPA Standard P9-A were used as carriers for these wood preservatives. After ten years exposure, the efficacy of Cu-Nap at a retention level of 0.05 pcf Cu was equivalent...
D D Nicholas, M H Freeman
Environmental impact of CCA poles in service
1997 - IRG/WP 97-50087
Soil samples from different depths and distances from CCA treated utility poles in Canada were analyzed for copper, chromium and arsenic content for a number of soil types, two wood species red pine (Pinus resinosa) and jack pine (P. banksiana) and different pole ages in service. A limited number of poles were equipped with water traps to collect rain water that dripped down the poles and where su...
P A Cooper, Y T Ung, J-P Aucoin
Moulds and indoor climate in Denmark
2003 - IRG/WP 03-10488
Just like in many other countries after the oil crisis in 1972 Danish houses were tightened with the result that the relative air humidity rose considerably. The Ministry of Energy also demanded a lowering of the indoor temperature from 25°C to 20°C with the result that the relative air humidity rose even more. According to the latest survey 10% of Danish buildings are infected with moulds. Moul...
J Bech-Andersen, S A Elborne
Virulence testing of cultures of different origins of the test fungus Coriolus versicolor strain CTB 863 A
1986 - IRG/WP 2267
The virulence of cultures of different origins of Coriolus versicolor CTB 863 A - a strain which is mentioned in EN 113 - was tested. Standard blocks of beech wood were used at temperatures of 20-22°C and 26-28°C and particleboard was tested at 26-28°C. The decay capacity of the different inoculations varied widely, as could be expected it was greatest at the higher temperature level....
W Kerner
Biological agents of timber degradation in Portugal. Marine borers
1991 - IRG/WP 4171
A brief report of the studies carried out in Portugal on marine borers is presented. The marine borers found in the portuguese coast are refered as well as the wood species where those organisms were identified. Emphasis is given to a study carried out from 1960 to 1975 at the Tagus estuary in Lisbon with the purpose, among others, of establishing the natural durability of different timbers....
J S Machado, L Nunes
Ecotoxicological risks of anti-sapstain preservatives washed off from treated timber
2000 - IRG/WP 00-50144
A field method for ecotoxicity assessment of rain water wash-off from anti-sapstain treated timber was developed. In the course of this study freshly sawn timber treated with 1.5% Busan 30 L (reference preservative) and a control stack with untreated pine were exposed to weathering. The run-off water was ecotoxicologically tested with organisms from three trophic levels (Vibrio fischeri, Kirchneri...
G Aschacher, R Gründlinger