IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 79 documents. Displaying 25 entries per page.


A novel solvent penetration assessment technique for wood preservativation treatments using waterborne systems
1990 - IRG/WP 2346
Solvent and hence solute (a.i.) penetration during any wood preservation treatment cycle and the flow pathways taken by the solvent in the wood are crucial elements in determining the adequacy of any treatment. Inadequate solvent penetration into specimens or an inappropriate tissue throughflow pattern during impregnation will markedly affect the distribution pattern achieved by many non-diffusibl...
A J Pendlebury, J Coetzee, E Sorfa, A Botha


Durability of surface coating systems. Mycologg - an accelerated mycological test.
2004 - IRG/WP 04-20301
Field testing and natural aging/degradation of test sample, e.g. coated wooden surfaces is a slow process. Accelerated tests focus on mechanical properties, water uptake or sometimes stain fungi. Artificially weathered coated panels are not easily compared with naturally aged panels, and show the importance of involving the biological component among the degrading facors. It is a need for acce...
L Ross Gobakken, J Mattsson, B Jacobsen, F G Evans


Blue stain in timber in service. Results of further IRG collaborative tests to compare different artificial weathering systems
1981 - IRG/WP 2146
The previous work described in Document No IRG/WP/286 examined 3 preservatives (1% phenyl mercury succinate - PMS, 5% pentachlorophenol - PCP and 1.5% Preventol A4 - PA4) subjected to 5 different artificial weathering systems (BAM Xenotest, Cuprinol Marr, EMPA Xenotest, Gori Atlas and PRL Marr) and after natural weathering at 5 sites (BAM, Cuprinol, EMPA, Gori and PRL). Results showed good correla...
A F Bravery, D J Dickinson


Laboratory evaluation of six commercial termiticides against subterranean termite, Coptotermes gestroi Wasmann
1994 - IRG/WP 94-30034
Small specimens of Heavea brasiliensis (10 x 10 x 20 mm³) were exposed to the laboratory colony of Coptotermes gestroi Wasmann for 4 months after dip- or brush-treatment with six commercially available emulsifiable termiticides (alpha-cypermethrin, cypermethrin, permethrin, bifenthrin, chlorpyrifos and chlordane). Synthetic pyrethroids and chlorpyrifos were effective as well as 1% treatment of ch...
Y Sornnuwat, C Vongkaluang, T Yoshimura, K Tsunoda, M Takahashi


Blue stain in service on wood surface coatings. Part 1: The nutritional requirements of Aureobasidium pullulans
1992 - IRG/WP 92-1556
The nutritional requirements of Aureobasidium pullulans was examined with regard to nutrient sources that are potentially available in fresh and weathered wood. The study was designed to determine how far wood cell wall components need to be broken down during weathering before they provide a useful nutrient source for Aureobasidium pullulans. Various carbon sources were tested, with eight differe...
P R Sharpe, D J Dickinson


Multicomponent biocide systems protect wood from decay fungi, mold fungi, and termites for interior applications
2004 - IRG/WP 04-30333
Concerns about indoor air quality due to mold growth have increased dramatically in the United States. In the absence of proper moisture management, fungicides need to be developed for indoor use to control mold establishment. An ideal fungicide for prevention of indoor mold growth on wood-based materials needs to specifically prevent spore germination and provide long-term protection under condit...
C A Clausen,V W Yang


Efficacy of copper:propiconazole and copper:citrate systems in ground contact exposure at a site with copper tolerant fungi
2003 - IRG/WP 03-30305
Southern yellow pine (SYP) sapwood field stakes were treated with copper alone (ammoniacal copper carbonate, ACC) at four levels, or three levels of copper (1.6, 3.2, or 6.4 kgm-3, as CuO), air-dried, then re-treated with propiconazole in a light organic solvent at 0.07, 0.3, or 0.7 kgm-3 retentions. In a separate study, SYP field stakes were treated with three levels of ACC to give 6.7, 13.4 or ...
D D Nicholas, T Schultz


A novel chemical barrier system, KORDON® TMB, for the protection of buildings against subterranean termites using a synthetic matrix as carrier for the chemical
1998 - IRG/WP 98-10264
Kordon TMB is a new chemical barrier system for installation beneath concrete slab-on-ground constructions using a matrix other than soil as carrier for the termiticide. The product consists of a synthetic foraminous web (blanket) carrying the synthetic pyrethroid deltamethrin. The blanket is laminated on the upper side to a standard 0.2mm thick moisture vapour membrane of low density polyethylene...
M Lenz, P Morrow, S Runko


Industrial fixation systems: key factors, limitations and optimisation through the use of computer simulation modelling. Discussion paper
1994 - IRG/WP 94-40026
This paper briefly describes four fixation operative in the Netherlands, namely: circulating and non-circulating steam fixation cylinders, steam fixation chambers and controlled climate rooms. The general limitations of industrial practice are reviewed against the background of established fixation theory. The controlling variables, both material and process-related, for fixation processing are sp...
A J Pendlebury, M Riepen, M J Boonstra, W Gard


The loss of insecticidal action from synthetic pyrethroid-treated wood samples: The effect of high temperatures and relative humidities
1992 - IRG/WP 92-1569
This paper describes the results from bioassays using Hylotrupes bajulus, and chemical analyses, of pyrethroid-treated wood samples following storage for up to 3 years. A range of four storage environments was used consisting of combinations of two temperatures (20°C and 40°C) and two relative humidities (60% and 90%). It is concluded from the chemical analyses that, although losses at room temp...
R W Berry, S J Read


Standard and accelerated testing of boron-additive wood protection systems
2005 - IRG/WP 05-30381
The main objective of this research was to determine the effectiveness of boron-additive protection systems for above ground applications by means of field testing. The two field test procedures used are based on the L-joint test described in the European standard EN 330. For the first set up the boron treated timber was coated in accordance with the standard EN 330 system. The second set up is ba...
A Mohareb, J Van Acker, M Stevens


The relationship between preservative type and surface degrade in Pinus radiata
1980 - IRG/WP 3158
Samples of Pinus radiata D. Don were impregnated with one of two preservative types, a copper chrome arsenic salt and a light organic solvent preservative. The panels were exposed to the weather for 4-5 years at a site near Sydney, Australia. Macroscopic and microscopic examinations showed different rates and patterns of weathering between the samples treated with each preservative and an untreate...
R S Johnstone, R K Bamber


Further steps in the development of above ground wood preservative systems
2002 - IRG/WP 02-30300
Metal and organo-metallic wood preservative systems have provided the consumer with cost effective wood preservative systems which satisfy the performance requirements in a wide range of end uses. With increasing environmental and legislative control, metal-free formulations have emerged as the dominant preservative systems for the protection of timber in the lower hazard classes. In higher ha...
P Warburton, A S Hughes


Increased biological durability differs for traditional wood preservation and new non-biocidal systems (NBS)
2000 - IRG/WP 00-20212
Wood preservation is a way to increase the biological durability of wood by the addition of chemical components with a biocidal effect. The effect of such treatment is clearly concentration dependent. At distinct levels of fungicide concentration fungi are killed or inhibited in their enzymatic functioning to provide nutrients. The toxic limits allow decision-makers to provide treating prescriptio...
J Van Acker, M Stevens


A real scale evaluation method and results on termite resistance of housing wall systems and floor framings
1999 - IRG/WP 99-10314
For evaluating the termite resistance of real scale houses especially housing wall systems and floor framings, a experimental building was prepared. After initial feeding of termite, this house was constructed. In this experimental building, several parts which were built by different wall systems and floor framing. The room temperature of these parts were controlled. Water can be provided in the ...
K Suzuki, K Okada, K Hagio, Y Tanaka


Preliminary agar screening studies as the first stage in the development of a biological control system against basidiomycetes in ground contact situations
1995 - IRG/WP 95-10111
Preliminary screening of Trichoderma isolates as possible biocontrol agents for protection of wood in ground contact situations against basidiomycete decay was undertaken on three types of media. Media used were 3% malt extract agar (MEA); a low nutrient synthetic media with a carbon: nitrogen ratio typical of that found in softwoods (LNM); and a similar synthetic media where the amino acid profil...
E J B Tucker, A Bruce


The effect of synthetic pyrethroid insecticides on post-treatment emergence of Anobium punctatum
1992 - IRG/WP 92-1568
Data is presented from trials in which wood specimens, treated with a range of remedial insecticidal formulations, were aged in a roof void for 5 years and then tested for emergence of adult Anobium punctatum. The technique used followed that described in IRG/WP/2175. The results from formulations containing synthetic pyrethroids are compared with those from formulations containing the chlorinated...
R W Berry


Production of monoclonal antibodies to Serpula lacrymans and their application in immunodetection systems
1993 - IRG/WP 93-10004
Monoclonal antibodies were produced against both whole cell mycelial extracts and exo-antigen extracts of the causative organism of dry rot, Serpula lacrymans. The antibodies were tested for cross-reactivity against fifteen strains of Serpula lacrymans and nine other fungal species. These species represented either other wood decay fungi or non-decay fungi commonly co-isolated with Serpula lacryma...
H Glancy, J W Palfreyman


Compatibility of deltamethrin with wood-finishing and construction materials
1993 - IRG/WP 93-30010
Under normal use conditions, treated wood comes to close contact with the structural components of a buiLding, and/or receives finishing, forming a new interface, which can affect the performance of a new product such as deltamethrin. To study this possibility, block-tests of Parana-Pine (Araucaria angustifolia), measuring 12 x 24 x 0.5 cm³ (with the largest dimension parallel to the wood-grain),...
E S Lepage


Partial seasoning and preservative treatment systems for pine roundwood
1982 - IRG/WP 3187
Experimental trials at FRI, Rotorua showed that the steaming schedule normally used for steaming and venting is also suitable for steaming and vacuum seasoning. Applying vacuum of up to -84 kPa immediately after steaming did not increase the initial loss of wood moisture significantly in comparison to steam/venting. The main improvement to wood condition by using steam/vacuum appeared to be to dis...
A J Bergervoet


The effect of high and low boron soils on foraging termite behaviour and their metabolic systems
2007 - IRG/WP 07-10602
The highest concentrations of boron are found in ground water and soils of some of the driest climate areas (arid and semi arid regions) in the world. This present study examined the various concentrations of boron levels on filter papers against the subterranean termite species Coptotermes from different provenances and different boron soil levels. The termites were presented with no-choice bioas...
B M Ahmed, J R J French, P Vinden


Use of the Digital Refractometer for the On-site Analysis of Copper-based Preservative Systems
2007 - IRG/WP 07-20371
In some counties, there are no on-site chemical analysis methods available for treatment plants to use to determine the key active ingredients in the preservative treatment solutions. The complexity of the sophisticated methodology; cost of analytical instruments and training required for operating these instruments in treating plant level are the reasons for lacking such practice. In this paper...
L Jin, T Cashman, A Preston, J Trompetter, H Trompetter


Growth and succession of mould on commercial paint systems in two field sites
2007 - IRG/WP 07-30421
Discolouring fungi reduce the service life of coated wooden claddings in façades and increase the total cost of ownership due to shorter maintenance intervals. It is of major importance to find paint systems for wood which are durable and have a high resistance to mould growth. A total of 15 paint systems from 9 different manufacturers were exposed on two field sites, Sørkedalen and Birkenes, ...
L Ross Gobakken, K M Jenssen


Bending Properties of Southern Pine Treated with Micronized Preservative Systems
2008 - IRG/WP 08-40414
This study indicates that treatment of southern pine with micronized copper systems have no deleterious effect on the residual strength property values. No statistical differences between wood treated with micronized systems and water-treated controls were noted when means were compared using either Tukey’s test or S-N-K mean comparison tests. Using the more discriminating Least Squares anal...
H M Barnes, G B Lindsey, J Hill, M Pompeo, R Hodge


Above Ground Field Testing – Influence of test method and location on the relative performance of various preservative systems
2008 - IRG/WP 08-20393
Standardized above ground tests such as the lap-joint or test deck methods can be very slow in producing useful information on the relative performance of wood preservative systems. It often requires many years for decay to develop in wood treated to sub-optimal concentrations of standardized preservatives, making relative comparisons of performance between new systems and established preservativ...
A Zahora


Previous Page | Next Page