IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 481 documents. Displaying 25 entries per page.


Treatability of plywood containing intermountain Douglas fir veneers
1982 - IRG/WP 3203
Eighteen sheets of plywood were obtained which contained intermountain Douglas-fir veneers from two regions of British Columbia. Following pressure treatment with chromated copper arsenate (CCA type C) and ammoniacal copper arsenate (ACA) the preservative penetration and retention in individual veneers was assessed. It was concluded from the study that the intermountain Douglas-fir veneer could no...
J N R Ruddick, A Walsh


Response of the Formosan Subterranean Termite (Coptotermes formosanus) to Cellulose Insulation Treated with Boric Acid in Choice and No-Choice Tests.
2004 - IRG/WP 04-10532
The tunneling ability of the Formosan subterranean termite Coptotermes formosanus Shiraki through a cellulose insulation material containing11.1% boric acid was tested in choice and no-choice bioassays. We examined tunneling behavior and mortality of termites exposed to treated and untreated insulation material in miniature simulated wall voids. In a choice test termites tunneled through untreat...
M E Mankowski, J K Grace


Termite and decay protection - A superficial barrier field test
1983 - IRG/WP 3257
Samples of Pinus radiata were given a superficial barrier treatment and installed in the ground at two sites for five years to observe termite and fungal attack. The three best treatments of the series were Denso petroleum tape, Koppers hot dip tar enamel, and Arquad 2C/75 alkyl ammonium compound. As new fungicides and insecticides become available they are being added to the test using the same s...
R S Johnstone, W D Gardner


Controlling Coptotermes (Isoptera: Rhinotermitidae) infestations in buildings with bait boxes
2000 - IRG/WP 00-10372
This paper describes the results of a commercial pest control operators use of the CSIRO bait box procedure in controlling infestations within buildings of subterranean termites ('termites') of the genus Coptotermes. Polystyrene bait boxes (480 x 330 x 210 mm3) were filled with alternate layers of corrugated cardboard and kiln-dried hardwood strips of Eucalyptus regnans F. Meull....
J R J French, T Boschma


Biological control of the Formosan subterranean termite Coptotermes formosanus Shiraki
1971 - IRG/WP 100
M Tamashiro, J K Fujii, P Lai, T E Richardson


Preliminary attempts towards the development of a small scale termite rearing chamber. Progress report
1983 - IRG/WP 1203
The results suggest that there is no evidence that the volume of the rearing chamber plays a part in the settlement of a colony. These rearing chambers present a factor of productivity (final enumeration)/(initial enumeration) of roughly 2 after one year. 90% of the colony survived. This method of breeding can be considered as feasible and cheap....
M Argoud, J C Palla, R Sternalsky


Système informatisé d'aide à la décision pour la gestion de la migration du pentachlorophénol dans l'environnement
1993 - IRG/WP 93-50001-10
This paper describes a Decision Support System (DSS), concerning pentachlorophenol (PCP) migration in the environment. The principal objectives of the DSS are to assist managers in siting of PCP-treated poles in the Hydro-Québec system and the storage areas and in the treatment of customer complaints. Four mathematical models are incuded in the system: a model simulating migration inside and on t...
G Lefebvre, J-C Tessier


What can DNA fingerprinting, aggression tests and morphometry contribute to the identification of colonies of the Formosan subterranean termite
2000 - IRG/WP 00-10371
Multilocus DNA fingerprinting, aggression tests and morphometry were compared to evaluate their potential for the identification of colonies of the Formosan subterranean termite, Coptotermes formosanus (Isoptera: Rhinotermitidae) in Hawaii. DNA fingerprinting separates the termites from all studied collection sites. Since the genetic similarity between termites from different collection sites lies...
C Husseneder, J K Grace


Sequential exposure of borate treated Douglas-fir to multiple Formosan subterranean termite colonies in a 40-week field test
1993 - IRG/WP 93-10006
Douglas-fir boards (ca. 74.5 g) pressure-treated with disodium octaborate tetrahydrate (DOT) retentions of 0 (controls), 0.88, 1.23, 1.60, or 2.10% (weight/weight) DOT were sequentially exposed to four active field colonies of Formosan subterranean termites, Coptotermes formosanus Shiraki (Isoptera: Rhinotermitidae), in an above-ground field test. Samples were placed in contact with each colony fo...
J K Grace, R T Yamamoto


Results on termite resistance of building materials against Coptotermes formosanus by choice test
1998 - IRG/WP 98-10275
Various building materials, included wood species, wooden board materials, thermal insulation materials and fire-protection materials, were tested for grading of termite resistance against Coptotermes formosanus. The dimension of most specimens were 2x2x2cm3. Ten repeats were prepared. The specimens were put between Akamatsu sapwood control specimens on a laboratory cultured mound colony of termit...
K Suzuki, K Hagio


Termite standards questionnaire survey
1987 - IRG/WP 1324
J R J French, J P La Fage


Termite researcher questionnaire
1985 - IRG/WP 1274
J P La Fage


Development of a Granitgard® particulate termite barrier for use in tropical Australia
1997 - IRG/WP 97-10190
Granitgard® is superficially simple technology; graded crushed aggregate, sieved to a size range impenetrable to subterranean termites. However, behind this apparent simplicity lies a large research effort. In this paper we describe the laboratory development of a grading of Granitgard suitable for use against the wide range of termites which attack timber in northern Australia, above the Tropic ...
D M Ewart, E R Rawlinson, A D Tolsma, G C Irvin, P R Wiggins


Studies on the foraging of subterranean termites
2000 - IRG/WP 00-10345
To study the foraging galleries of subterranean termites in soil, early researchers painstakingly excavated underground tunneling system of these cryptic insects. Erhorn (1934) listed a report by Oahu Sugar Co., Ltd. in 1928 showing that runway of Coptotermes formosanus may extend up to 50 m long and 0.3 - 3 m deep. Ratcliffe & Greaves (1940) who excavated foraging galleries of Coptotermes lac...
N-Y Su


Experimental real building evaluation of termite attack - Effect of the space between the mat foundation and the thermal insulation
2000 - IRG/WP 00-10374
For evaluating the termite resistance of the real house foundation, specially in the case of thermal insulation systems for foundation walls, thermal insulation which can be attacked by termite, must be evaluate. Because of the difficulty of the water penetration of thermal insulation, the water barrier systems can be protected against termite attacks, in our opinions. The observation on the proce...
K Suzuki, K Hagio, Y Tanaka


Wood preservation in the Australian beekeeping industry
1988 - IRG/WP 3473
This paper reports the results of a survey of Australian commercial beekeepers working 200 or more hives in June/July 1985. Nine hundred and forty seven apiarists were asked to participate and to provide information on their wood preservation methods, painting procedures and maintenance of bee boxes. Three hundred and eighty-four apiarists returned completed questionnaires (41%). The main wood pre...
P J Robinson, J R J French


A critical review of the AWPA standard method (M12-72) for laboratory evaluation to determine resistance to subterranean termites
1986 - IRG/WP 1298
The American Wood Preservers' Association standard (M12-72) for evaluation of candidate wood preservatives against subterranean termites is reviewed and suggestions for revision are made. The most serious flaws in the current test procedure involve a failure to recognize inter- and intraspecific variation and a lack of quantification of test results....
J P La Fage, M Jones


Baiting techniques for subterranean termite control
1983 - IRG/WP 1205
The use of artificial baits, with and without toxins, have proved effective in attracting large numbers of non-mound and mound building subterranean termites in both urban and rural areas. An outline is presented of a termite baiting program which emphasises concurrent laboratory and field investigations on termite ecology, behaviour and physiology...
J R J French, J P Robinson


Preliminary attempts towards the development of a small-scale termite rearing chamber
1982 - IRG/WP 1148
The paper suggests how to prepare a small-scale rearing chamber for termites which might be used for testing the effectiveness of possible termiticides. A technique for breeding the termites is suggested....
M Argoud, J Mocotte, R Sternalsky


Techniques for field assessment of particulate termite barriers
2000 - IRG/WP 00-10376
Field testing of particulate termite barriers poses problems different from those encountered when testing preservatives or soil termiticides. To ensure an adequate level of challenge, and minimise the risk of a Type II error, the experimental design must promote termite activity and provide a significant, readily detectable, food source which can only be reached by penetrating the test barrier. I...
D M Ewart, E R Rawlinson


Differences in feeding activity among colonies of Formosan subterranean termite Coptotermes formosanus Shiraki
1983 - IRG/WP 1202
Feeding activities of 7 colonies of the Formosan subterranean termite, Coptotermes formosanus Shiraki, were examined. Wood-consumption rates among colonies differed significantly, ranging from 23.80-78.48 mg/g/day. This large intraspecific variation raised a question of whether differences in feeding activity reported for other termite species were due to interspecific differences. When rates were...
N-Y Su, J P La Fage


Treatment of Douglas fir heartwood with disodium octaborate tetrahydrate (Tim-BorÒ ) to prevent attack by the Formosan subterranean termite
1991 - IRG/WP 1487
Toxicity of disodium octaborate tetrahydrate (Tim-BorÒ) to Coptotermes formosanus Shiraki (Isoptera: Rhinotermitidae), and termite feeding on treated Douglas-fir heartwood were evaluated in laboratory and field tests. Feeding on filter papers impregnated with Tim-BorÒ solutions reduced but did not eliminate termite gut protozoan populations. In a forced-feeding laboratory assay, Douglas-fir hear...
M Tamashiro, R T Yamamoto, J K Grace


WG I Sub-group 4 Termite problems: Documents before the meeting
1983 - IRG/WP 1215
IRG Secretariat


CCA Chemistry
1983 - IRG/WP 3268
A Pizzi


Minutes of WG I, Sub-group 1 Termite problems
1983 - IRG/WP 1219
IRG Secretariat


Previous Page | Next Page