A new approach to the maintenance of wooden railway sleepers. (Second report)
1988 - IRG/WP 3492
The microenvironment and micro-ecology of wooden railway sleepers was investigated to assess their condition to determine the necessary treatment, repair and replacement criteria. In this report the efficacy of the secondary preservative treatment with solid boron rods is discussed and the development of an in-situ, nondestructive test method based on the creation and assessment of structural dyna...
W Beauford, P I Morris, A M Brown, D J Dickinson


HCB - a new preservative combination for wood pole maintenance
1996 - IRG/WP 96-30122
New combination of heavy creosoted boron (HCB) applied on hardwood and softwood logs at different moisture content revealed successful diffusion of boron in all sapwoods within 7 days and in all sapwoods plus hardwoods within 15 days. The new cost effective paste sterilizes wood through diffusion and suitable for pole maintenance at groundline and above groundline e.g. cut ends, drilled holes, woo...
A K Lahiry


The secondary treatment of creosoted electricity poles with fused boron rods
1988 - IRG/WP 3485
After preliminary trials selected poles were treated at the groundline with fused boron rods. Early samplings showed that movement was slow in the dry heartwood but after six years the distributions obtained indicate that the system has merit for the treatment of the heartwood of poles in service....
D J Dickinson, P I Morris, B Calver


Effects of alkali treatment on some mechanical and chemical properties of creosote treated oaks
1991 - IRG/WP 2366
To date, there is a lack of information on the effects of chemical treatment on the performance of creosote preservative treated oak sleepers. This factorial experiment was designed to analyze three main effects: species (Quercus alba and Quercus rubra) creosote treatment (treated and untreated), and alkali (NaOH) soaking (0, 1, and 10 percent). The modulus of elasticity (MOE) and fiber stress at ...
P Chow, A J Reinschmidt, E J Barenberg, L C Chang


Treatability of waterstored poles of Norway spruce by sap-displacement and pressure treatment with Boliden K33 and creosote
1973 - IRG/WP 328
Poles of windthrown Norway spruce were stored in bark under water sprinklers for 11-20 months or fully submerged in a lake for 3 years (tab. 1 and 2). Water content after storage is shown in fig. 1 and 8. Treatment with Boliden K33 by sap-displacement (open tank suction) gave a poor result. The Danish requirements of delivery claim a penetration of 20 mm and a net retention of 12 kg/m³ in outer 2...
P Moltesen, E Borsholt, B Bang


Remedial ground-line treatment of CCA poles in service. Results of chemical and microbiological analyses 6 months after treatment
1986 - IRG/WP 3388
CCA-treated poles in service with incipient internal soft rot were remedially treated by inserting borate rods, brushing with a boron/glycol solution and injecting boric acid paste, copper/creosote paste or a commercial product (DFCK paste). The spread of active chemicals in the treated zone as well as the change in microflora have been studied with time. After six months chemicals had spread to m...
B Henningsson, H Friis-Hansen, A Käärik, M-L Edlund


Remedial ground-line treatment of CCA poles in service. A final report after 60 months' testing
1989 - IRG/WP 3534
Remedial treatment of CCA treated utility poles of Pinus sylvestris with incipient decay was carried out in 1983 and the results of chemical and microbiological analyses 6 months after treatment were reported in Document No: IRG/WP/3388 while microbiological studies 12 and 28 months after treatment as well as chemical analyses of poles treated with boron rods or boric acid paste 28 months after tr...
B Henningsson, H Friis-Hansen, A Käärik, M-L Edlund


Development of a model system to assess the efficacy and environmental impact of a chromated fluoride remedial treatment for creosoted distribution poles
1992 - IRG/WP 92-2395
A closed model system was designed to facilitate a controlled study of the leachability and environmental fate of a remedial preservative under laboratory conditions. The elements of the model include a precipitation apparatus above a treated pole section which is positioned in a representative soil profile supporting a sward of perennial ryegrass. The model will allow detailed examination of the ...
D C R Sinclair, G M Smith, A Bruce, B King


Diffusion of chromium and fluoride in Rentex treated creosoted pole sections
1991 - IRG/WP 3659
A chromated fluoride preservative was applied by injection to the groundline regions of creosoted distribution pole sections and these were erected at a filed site in Scotland. Wood samples were recovered for chemical analysis at one week, two, five and twelve months after treatment. Small sample mass and destructive nature of the analysis necessitated modification of an alkali fusion technique to...
D C R Sinclair, G M Smith, A Bruce, B King, H J Staines


An appraisal of the vertical distribution of attack of untreated and treated wood by warm water sphaeromatids at some tropical sites - A discussion paper
1986 - IRG/WP 4124
Examples of the vertical distribution of burrows of warm water sphaeromatids relative to tide levels and mud line from sites in India, Papua New Guinea and tropical Australia are discussed in detail. These data show clearly that these animals concentrate their attack of resistant natural wood or resistant treated wood in the tidal zone, particularly around Mean Sea Level. Supportive evidence from ...
J E Barnacle, L J Cookson, C N McEvoy


Further progress towards a cleaner creosote treatment - Summarised report
1984 - IRG/WP 3304
This document provides an up-dated progress report on our development of pigment emulsified creosote (PEC) used as a cleaner alternative to conventional high temperature creosote. A range of commodities (both hardwood and softwood) has now been satisfactorily treated in pilot plant and full scale commercial operations. Both brown (PEC 30B) and white (PEC 30W) formulations have been used. In additi...
H Greaves, C-W Chin, J B Watkins


Adequate preservative treatment of kiln dried Eucalyptus camaldulensis and Acacia mangium for tropical and subtropical wood poles
1996 - IRG/WP 96-40075
The Eucalyptus camaldulensis and Acacia mangium round timbers kiln-dried at EMC and full cell pressure treated with CCA-C ensured requisite penetration and adequate dry retention (30 kg/m³ or 4% w/w). The sufficient inherent strength, seasoning property, treatability of sapwood and heartwood equivalent to 44% of radius, natural durability of heartwood, and field investigation on service performan...
A K Lahiry


Clean creosote - its development, and comparison with conventional high temperature creosote
1983 - IRG/WP 3235
Pigment emulsified creosote (PEC) is presently being tested and shows considerable stability in terms of water content, pigment level, pH, viscosity, rheological behaviour and microscopy. Timber samples from several eucalypt species have been treated with PEC and side matched samples treated with conventional high temperature creosote (HTC). The PEC treated specimens showed higher weight retention...
C W Chin, J B Watkins, H Greaves


Improved preservative penetration of spruce after pre-treatment with selected fungi. II. Creosote treatment, analysis and strength testing
1998 - IRG/WP 98-40106
This paper describes the creosote treatment and analysis of logs pre-treated with selected fungal agents as a method of increasing the porosity of the wood prior to preservative treatment. The paper also reports the subsequent strength testing of the timber to evaluate the effects of the fungal pre-treatment on the structural integrity of the wood. European spruce logs were pre-treated with eithe...
E J Tucker, A Bruce, H J Staines, B Rosner, K Messner


Remedial ground-line treatment of CCA poles in service. A progress report after 28 months' testing
1988 - IRG/WP 3481
Remedial treatments of CCA-treated poles in service with incipient soft rot were carried out with boron rods, boron/glycol solution, boric acid paste, copper/creosote paste and a commercial product (DFCK paste) respectively. The micro-flora before remedial treatment and 6 months after as well as the spread of chemicals in the poles were reported in Document No: IRG/WP/3388. In this progress report...
B Henningsson, H Friis-Hansen, A Käärik, M-L Edlund


Influence of different treatment parameters on penetration, retention and bleeding of creosote
2003 - IRG/WP 03-40255
Creosote is an extensively used preservative for transmission poles and sleepers. The purpose of this research was to investigate the treatment parameters necessary to achieve full sapwood penetration and minimum required retention and to avoid bleeding of creosote. It was carried out as a part of the European research project WOODPOLE. Transmission poles of Scots pine (Pinus sylvestris L.) previo...
Ö Bergman


Studies on the determination of the durability of wooden poles and fence posts
1982 - IRG/WP 3195
This study was carried out by the Forestry Research Institute. 5 Turkish main tree species, Oak (Quercus), pine (Pinus sylvestris), beech (Fagus orientalis) and Fir (Abies bornmülleriana) wooden poles and fence posts, were treated with Tanalith-U and creosote applying pressure process. Tanalith-U was applied by full-cell process and creosote was applied by empty cell process. Treated and untreate...
R Ilhan, O Taskin, A P Erten


Assessment of the effects of rentex remedial treatment on some wood pole inhabitant micro-organisms
1994 - IRG/WP 94-30053
The effects of a remedial ground-line treatment using Rentex, a stabilised paste containing a mixture of fluoride and dichromate salts, on the micro-organisms inhabiting a sample of some 160 creosoted, on-line, electricity distribution poles, have been investigated as part of an appraisal of the efficacy of this remedial treatment. Half of the poles were treated and the other half used as controls...
D C R Sinclair, G M Smith, A Bruce, H J Staines


Quantification of creosote migration down wooden poles and the prevention of its depletion during flood irrigation
1994 - IRG/WP 94-50032
Polyethylene field liners heat-shrunk onto soil-contact surfaces prevented decay of creosote-treated Eucalyptus grandis vineyard poles under flood-irrigation. The present work quantified losses of creosote from these poles after six and 24 months' service. After six months' service the mean creosote retention of unlined poles above the ground line was 12.62% (m/m dry wood), with ...
M Behr, A A W Baecker


Effectiveness of wood preservatives and treatments against marine borers in Philippine waters
1976 - IRG/WP 416
A 5-year exposure test was conducted on the effectiveness of wood preservatives and treatments against marine borers in Philippine waters. Air-dried heartwood samples of apitong (Dipterocarpus grandiflorus) 76.2 x 88.9 x 609.6 mm³ (3 x 3.5 x 24 in³) in size were pressure treated with coal tar creosote and two types of CCA (copper/chrome/arsenic) and CuCZA (copperized chromated zinc arsenate) wat...
F R Siriban, M G Laxamana, P G Mata


Quantification of creosote and fluoride in remedially-treated poles
1997 - IRG/WP 97-40097
Three creosoted transmission poles were put into service in 1961 and they were subsequently remedially-treated with a proprietary fluoride remedial paste formulation in 1981. The poles were removed from service in 1996 and their ground-contact regions were analysed for creosote and fluoride contents. It was found that the poles were undecayed. Creosote retentions decreased down the profiles of the...
B P Hill


Penetration of oil-borne preservatives in American elm
1975 - IRG/WP 355
Pressure treatment of elm posts and cants by Rueping schedules resulted in erratic penetration. Instead of the expected gradual decrease in retention from surface inward in posts, inner zones frequently contained more preservative than the surface quarter inch. Heartwood was found penetrated when sapwood was not. There were numerous skips in treated zones. The prevalence and possible causes were i...
E A Behr


Conforming to European standards on preservative treatment
1998 - IRG/WP 98-20150
New European standards require that specifications for the preservative treatment of timber are written in terms of the penetration and retention of preservative within the treated commodity that result from the treatment process. In order to check compliance with this type of specification, suitable methods of quantitative analysis must be available. This paper presents the results of a study by ...
E D Suttie, R J Orsler


A field evaluation of chromated fluoride as a remedial treatment for creosoted wooden distribution poles
1989 - IRG/WP 3556
A commercial chromated fluoride formulation was applied by injection process to previously inoculated creosoted wooden distribution pole sections at a field site in Scotland and appraisal of the efficacy of the formulation against Lentinus lepideus was undertaken at two month and fifteen month intervals. Preliminary results suggest a rapid elimination of organisms from colonised areas. The usage o...
B King, A Bruce


Hot and cold treatment in fence posts of Eucalyptus globulus, Castanea sativa, Pinus nigra and Pinus pinaster
1988 - IRG/WP 3489
An analysis is made of the treatment of fence-posts of Eucalyptus globulus, Castanea sativa, Pinus nigra and Pinus pinaster by hot and cold immersion in creosote. The temperatures of the different treatments were 60, 70 and 90°C. The posts were heated for one hour and then allowed to cool for 21 hours 30 min., and finally reheated for 1 hour 30 min. The greatest absorption rates were recorded in ...
C De Arana Moncada, A M Navarrete