IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 51 documents. Displaying 25 entries per page.


Review of candidate graded particle barrier testing methods in Australian Standard (AS 3660.3 – 2000): Assessment criteria for termite management systems
2009 - IRG/WP 09-20417
The Australian Standard (AS. 3660.3 – 2000) for assessment of candidate graded particle termite barriers is reviewed and suggestions for amendments are made. Areas requiring amending in light of current biological knowledge involve the inclusion of proprietary or patented systems rather than generic types; selection of test termites in the genus Coptotermes; duration of test periods; and inadequ...
J R J French, B M Ahmed (Shiday), B L Schafer


Techniques for field assessment of particulate termite barriers
2000 - IRG/WP 00-10376
Field testing of particulate termite barriers poses problems different from those encountered when testing preservatives or soil termiticides. To ensure an adequate level of challenge, and minimise the risk of a Type II error, the experimental design must promote termite activity and provide a significant, readily detectable, food source which can only be reached by penetrating the test barrier. I...
D M Ewart, E R Rawlinson


Preliminary laboratory and field evaluation on the performance of Rubbermite as a graded physical barrier against subterranean termite species in Australia
2012 - IRG/WP 12-10766
This paper describes the performance of Rubbermite as a potential graded particle barrier against two subterranean termite species of Coptotermes in laboratory and field test. The results of these bioassays suggest that Rubbermite is a viable control option against Coptotermes species in Australia, particularly against Coptotermes acinaciformis (Froggatt) and Coptotermes lacteus (Froggatt). Rubber...
B M Ahmed (Shiday), J R J French


Granitgard used as a partial and perimeter barrier in the protection of buildings against subterranean termites
1995 - IRG/WP 95-10114
The graded granite subterranean termite physical barrier, commercially marketed as Granitgard, has a Certificate of National Accreditation issued by the Australian Building Codes Board, and is included in Australian Standards. After several years in developing the specifications and installation techniques for Granitgard, it may be used to protect almost all footing designs. Granitgard can be simp...
D M Ewart, J R J French


Physical barriers and bait toxicants: The Romeo and Juliet of future termite control
1991 - IRG/WP 1503
Soil chemical barriers are considered by some to be the most important technique for protecting buildings against subterranean termites in Australia (and elsewhere), providing a barrier against termite penetration. However, there is no such thing as a barrier that is 100 per cent +protective. And given the worldwide problems of using organochlorine termiticides, public awareness of chemical pollut...
J R J French


Leaching of components from water-borne paints and fungitoxic effects
1995 - IRG/WP 95-20062
Water-borne model paints, acrylics and alkyd emulsion paints, of known composition were leached according to a procedure modified in accordance with ASTM 6271.1. The effectiveness of fungicidal compounds in the painted specimens before and after leaching was evaluated with a biotest in which Penicillium brevicompactum was used as a test fungus. The leaching of the fungicide Troysan Polyphase accor...
J Bjurman


A direct method for testing plywood and particle boards against fungal decay
1984 - IRG/WP 2214
A method directly inspired from the French standard testing method of the resistance of particle boards against fungal decay (AFNOR N° 51.295 May 1980) is described. But in that experimentation, the infestation is localized and realized in non sterile conditions. Small blocks of Fagus sylvatica (60 x 20 x 10 mm³) used as " inoculates " are infested with basidiomycetes, in Kolle flask for 4 to 6 ...
L N Trong


Termite standards questionnaire survey. Second Report
1989 - IRG/WP 1395
Information contained in replies received from IRG members responding to the survey continue to be summarised. Again, highlighted in this second report are the major termite species in the various zoogeographical regions, their damage ranking to timber-in-service, the chemicals used in control methods, and the status of the termite standards in the respondent countries....
J R J French, J P La Fage


Wood in concrete. Summary of discussion at IRG 14, Surfers Paradise, Australia
1984 - IRG/WP 3264
The performance of untreated and preservative treated wood when placed in direct contact with concrete was considered in a discussion session at IRG 14. While published reports in this area are scarce, research is in progress internationally and a variety of practices are currently available to minimize any additional hazard posed by contact with concrete. This report summarizes the points raised ...
R J Murphy


Soil chemistry and wood decay
1978 - IRG/WP 2109
Soil is a most complex biological, chemical and physical material; its study is effectively a separate branch of science but almost entirely in relation to ist ability to grow plants - this paper is intendet just to note some known facets that might have relevance to the decay of wood and the performance of wood preservatives....
E A Hilditch


Termite and decay protection - A superficial barrier field test
1983 - IRG/WP 3257
Samples of Pinus radiata were given a superficial barrier treatment and installed in the ground at two sites for five years to observe termite and fungal attack. The three best treatments of the series were Denso petroleum tape, Koppers hot dip tar enamel, and Arquad 2C/75 alkyl ammonium compound. As new fungicides and insecticides become available they are being added to the test using the same s...
R S Johnstone, W D Gardner


Surface Barriers for Protection of Culture and Heritage Wooden Objects from Insect Attack
2004 - IRG/WP 04-40286
Anoxic treatment is an environment friendly procedure for eradication of wood boring insects in wooden objects of cultural and historical heritage. However, after the anoxic treatment, wooden antiques remain susceptible to further insect attacks. Possible protection against insects could be provided by the so-called post-repression protective barriers. Potential coating materials for such barriers...
M Petric, M Pavlic, B Kricej, M Humar, F Pohleven


Termite barriers for new construction
2000 - IRG/WP 00-10341
Subterranean termite protection in Australia has traditionally relied upon the creation of a zone of poisoned soil under and around the structure to prevent termite attack from the ground. The transition away from persistent soil poisons which began with the withdrawal of cyclodienes in 1995 provided market opportunities for innovative barrier systems. The new barrier systems currently being used ...
D M Ewart


Termite physical barriers: Update on retrofitting Granitgard around 'mock-up' buildings after three years
1995 - IRG/WP 95-10118
This field experiment was installed three years ago (March 1992) to evaluate the effectiveness of Granitgard, the commercial name of a grade of crushed granite aggregate or "screenings", as a physical termite barrier when retrofitted around 'mock-up' buildings. The field site is located at Walpeup in the semi-arid mallee region of north-west Victoria (360 km from Melbourne), and ...
B M Ahmed, J R J French


Durability of surface preserved wood particle boards submitted to atmospherical influence
1995 - IRG/WP 95-40039
The worldwide problem of the continuously growing deficit of high quality natural wood material has caused the attempts of many research workers to find effective composites such as wood particle boards (WPBs) for replacing the massive wood for constructive purposes, depending on where the boards are exploited - in the open or under a shed, they are submitted to various climatic factors such as he...
L Valcheva


Worldwide in-ground stake test of acetylated composite boards
1997 - IRG/WP 97-40088
Acetylated wood composite stakes are being tested in ground contact (graveyard test) in seven fields around the world. Three types of acetylated wood composites were prepared: spruce fiberboard in Sweden, aspen fiberboard in Madison and rubber wood particle board in Indonesia. Two levels of acetylation were used, a high level of ~20% acetyl content and a low level of 10% acetyl content. Control bo...
R M Rowell, B S Dawson, Y S Hadi, D D Nicholas, T Nilsson, D V Plackett, R Simonson, M Westin


The case for non-chemical termite barriers in termite control
1989 - IRG/WP 1381
A brief outline of current non-chemical barriers in subterranean termite control and their use in Australia is presented. Recent use of non-chemical barriers in Hawaii has led to their evaluation in termite control here and elsewhere. In Australia, preliminary laboratory and field experiments have shown similar results to those found against Coptotermes formosanus in Hawaii, namely, Australian Cop...
J R J French


Surface Barriers for Protection of Culture and Heritage Wooden Objects from Insect Attack
2004 - IRG/WP 04-20286
Anoxic treatment is an environment friendly procedure for eradication of wood boring insects in wooden objects of cultural and historical heritage. However, after the anoxic treatment, wooden antiques remain susceptible to further insect attacks. Possible protection against insects could be provided by the so-called post-repression protective barriers. Potential coating materials for such barriers...
M Petric, M Pavlic, B Kricej, M Humar, F Pohleven


Influence of sampling on the composition of test solutions
1985 - IRG/WP 2235
For four commercial products of CCB-salts the influence of the kind of sampling on the composition of test solutions has been tested. For each product several 5 g samples have been taken at random, after careful mixing the content of each bottle, and after grinding the whole content. With each sample a 5% test solution was made and analyzed on the content of chromium, copper and boron. Altogether ...
H Willeitner, K Brandt


Early detection of brown-rot decay in southern yellow pine using immunodiagnostic procedures
1990 - IRG/WP 2356
Immunodiagnostic procedures have been used to detect incipient decay of southern yellow pine by six common brown-rot fungi. Rabbit polyclonal antibodies were raised to liquid culture fractions of the six fungi. The antibodies, after preadsorption to sawdust, were tested in particle agglutination assays, immuno-dot blot, and ELISA for their·ability to detect the decay organisms when they were grow...
C A Clausen, F Green III, T L Highley


Termite physical barriers: Is retrofitting with Granitgard an option?
1993 - IRG/WP 93-40011
Granite particles within the range of 2.4 to 1.7 mm diameter were recently adopted by the Standards Association of Australia as an alternative treatment to soil chemical barriers in protecting new buildings against subterranean termites. The granite substrate is sold under the commercial name, "Granitgard". However, there are many existing buildings that have no chemical or physical subterranean t...
J R J French, B M Ahmed


Dimensional lumber model demonstrates the sensitivity of the particle capture immunoassay in early detection of brown-rot fungi
1995 - IRG/WP 95-20058
A dimensional lumber model was designed to test the sensitivity of the particle capture immunoassay (PCI) compared to traditional methods of culturing and microscopic examination for detection of brown-rot fungi. Southern yellow pine 2 x 4's (5.1x10.2 cm²), and 86.4 cm in length, were inoculated on one end with the brown-rot fungus, Postia placenta, and tested over the full length of the...
C A Clausen, L Ferge


Detection of brown-rot antigens in southern pine
1996 - IRG/WP 96-20090
Brown rot fungal antigens were detected by particle capture immunoassay (PCI) in southern pine 2 x 4's beyond visible or culturable hyphal growth. Further analysis of test samples revealed changes along the 2 x 4's that could be grouped into zones. Zone 1, the point of inoculation through 6 cm, showed low pH, measurable oxalic acid, high moisture, and high protein. Zone 2, throug...
C A Clausen


Resistance to decay of particle boards: Presentation of a test method
1986 - IRG/WP 2260
The experimentations were undertaken on particle boards 35 and 50 mm thick. The rot resistance tests were carried out on specimens whose dimensions were 600 x 75 x 35 mm³ for particle boards 35 mm thick and 800 x 75 x 50 mm³ for particle boards 50 mm thick according to a method derived from the one described in the documents IRG/WP/2214 and IRG/WP/2243. Two exposure periods were used: 12 and 16 ...
G R Y Déon, N Trong


Termite physical barriers: Update on retrofitting Granitgard around 'mock up' buildings after four years
1996 - IRG/WP 96-10140
This field experiment was installed four years ago (March 1992) to evaluate the effectiveness of graded crushed granite stone, commercially marketed under the name, Granitgard, as a physical termite barrier when retrofitted around 'mock-up' buildings. The field site is located at Walpeup in the semi-arid mallee region of north-west Victoria (360 km from Melbourne), and there are ...
B M Ahmed, J R J French


Next Page