IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 20 documents.


Improvement of liquid penetration of wood by precompression under appropriate conditions and recovery process
1993 - IRG/WP 93-40014
A new system for enhancing the penetration of liquid into wood using a precompression treatment was designed, and the effects of compressive deformation and recovery on liquid uptake were evaluated. Precompression of up to 60% under appropriate moisture and heat conditions effectively increased the penetration of liquid into refractory wood samples of practical sizes without producing any strength...
I Iida, Y Imamura


Recovery of copper chromium and arsenic from old CCA treated commodities
1998 - IRG/WP 98-50118
Due to the expected increase in spent treated wood over the next several decades, numerous means to reuse and recycle preserved wood have been proposed. Burning this wood for cogeneration or recycling of CCA treated wood into reconstituted composites are possible methods, but they are limited to laboratory scale because of environmental air emission issues and the manufacturing process. In the av...
D P Kamdem, Wanli Ma, Jun Zhang, J Zyskowski


The recycling of CCA treated wood
1999 - IRG/WP 99-50140
Efforts to recover CCA from CCA-treated wood have been focused on the extraction of small wood particles. This work describes a method capable of removing CCA from retired CCA treated pine boards without. The percent removal of copper varied from 82% to 94%, 72% to 90% for chromium, and 84% to 98% for arsenic. The mechanical properties of boards after the extraction of CCA was reduced to 30% compa...
D P Kamdem


Recovery of copper, chromium, and arsenic compounds from the waste preservative-treated wood
1991 - IRG/WP 3651
In Japan, about 40 percents of waste wood is incinerated and the residue is dumped into the landfill site. The waste preservative-treated wood, which is mixed in nontreated wood, is incinerated in the same way, too. However, it will cause the serious problems that the gases contained with high concentration arsenic compounds are discharged from the smokestacks of the incineration facilities and th...
A Honda, Y Kanjo, A Kimoto, K Koshii, S Kashiwazaki


Kiln drying of LSOP treated timber: rate of solvent evaporation, overpaintability and recovery of the solvent
1992 - IRG/WP 92-3711
The rate of solvent evaporation from LOSP treated timber dried in a kiln at 35°C has been investigated. Around 50% solvent removal has been found to be consistent with good overpaintability using a water based acrylic primer. It has been demonstrated that an activated carbon solvent recovery system is capable of removing all the solvent vapour from the outlet of a commercial joinery drying kiIn, ...
P Warburton, L B Sheard


Recycling and disposal of timber treated with waterborne copper based preservatives
1993 - IRG/WP 93-50008
Recycling and disposal technologies are briefly reviewed. Details are given of chemical extraction techniques suitable for recovery of copper from timber treated with a new copper based preservative, and traditional chromium based products. Details of thermal decomposition tests according to the DIN 53436 protocol under flaming and non-flaming conditions are given. The decomposition products were ...
J A Cornfield, S Vollam, P Fardell


Application of paint primers after light organic solvent preservative treatment
1986 - IRG/WP 3381
The application of three alternative paint primers is investigated, including a slow-drying oil-based primer, a fast-drying oil-based primer, and a fast-drying water-based primer. The treatment schedules employed, in particular the evacuation period after treatment, have a marked effect on subsequent paintability. Priming can potentially be carried out immediately after treatment with approved Tim...
P Vinden


Development of a novel treatment process and its applications
1998 - IRG/WP 98-40111
An efficient treatment process called "Isostatic Compression Recovery (ICR) Process" for impregnating liquids into wood has been developed. The process comprises steps of isostatic compression of wood in the liquid at temperatures above its softening temperature and subsequent recovery of its original volume under liquid pressure. A large amount of surrounding liquid is absorbed into the wood in t...
T Arakawa, M Funato, A Hoshino, T Muraki


Thermal decomposition behavior of CCA-treated wood for safe disposal and the safe recovery of heavy metals through pyrolysis
2006 - IRG/WP 06-50238
If we could estimate the chemical changes in heavy metals by temperature in chromated copper arsenate (CCA)-treated wood during pyrolysis, it is expected that we could solve the environmental problems of heavy metals, which may occur during pyrolysis, and therefore, the thermal decomposition behavior of effective elements of CCA-treated wood was examined to find a safe disposal method. First, CCA-...
Dong Won Son, Dong-heub Lee, Sun-hae Cheon, Myung Jae Lee


Bifenthrin recovery from glue-line-treated plywood
2007 - IRG/WP 07-20355
Plywood and laminated veneer lumber (LVL) can be protected from termite damage by addition of bifenthrin to the adhesive used in product manufacture. However, conditions associated with this manufacturing process may lead to deterioration or immobilisation of the active ingredient. In order to determine compliance with treatment specifications, it is important that the concentration of a preservat...
J Norton, L Stephens


Primary Study on Compressed Preservative-treated Wood (CPW) for Outdoor Applications
2008 - IRG/WP 08-40412
In this study, the compressed wood samples pre-treated with hot water bath or water spraying were immersed in the ammoniacal copper quat –type D (ACQ-D) preservative solution to get compressed preservative-treated wood (CPW). The liquid absorption and the recovery rate of compression deformation of the compressed wood was determined, as well as the surface hardness, the distribution of density a...
Jinzhen Cao, Jia Mao


Rapid Microwave-Assisted Acid Extraction of Metals from Chromated Copper Arsenate (CCA)-Treated Southern Pine Wood
2009 - IRG/WP 09-50262
The effects of acid concentration, reaction time, and temperature in a microwave reactor on recovery of CCA-treated wood were evaluated. Extraction of copper, chromium, and arsenic metals from chromated copper arsenate (CCA)-treated southern pine wood samples with three different acids (i.e., acetic acid, oxalic acid, and phosphoric acid) was investigated using in microwave reactor. Oxalic acid wa...
Bin Yu, Chung Y Hse, T F Shupe


Hydrofluoroalkanes as carrier solvents for timber preservation
2009 - IRG/WP 09-40463
Hydrofluoroalkanes are a specific category of hydrofluorocarbon (HFC) commonly used in refrigeration applications. Some HFCs hold potential for use as carrier fluids for preservatives used to protect timber above ground. They do not share the most significant disadvantages of currently used carriers for these applications. At ‘conventional’ operating pressures, they are capable of rapid, full ...
M J Kennedy, B Walker, C Erskine


Effect of Nano-Silver Treatment on Densified Wood Properties. Part One: Swelling, Recovery Set, Bending Strength
2010 - IRG/WP 10-40533
In this research the effect of Nano-Silver treatment on compressed wood properties, was studied. Wood specimens were cut from Popolus alba (poplar) and impregnated with Nano-Silver and water. Then the saturated samples were compressed through radial direction in a hot press under pressure of 6 MPa, for 1 and 4 hours. The temperatures of press were 150°C and 175°C. Swelling (24h), recovery set ...
G Rassam, H Reza Taghiyari, B Jamnani, M Ali Khaje


Microwave-Assisted Organic Acids Extraction of Chromate Copper Arsenate (CCA)-Treated Southern Pine
2010 - IRG/WP 10-50267
The extraction effects of acid concentration, reaction time and temperature in a microwave reactor on recovery of CCA-treated wood were evaluated. Extraction of copper, chromium, and arsenic metals from chromated copper arsenate (CCA)-treated southern pine wood samples with two different organic acids (i.e., acetic acid and oxalic acid) was investigated using a microwave reactor. Oxalic acid was e...
Bin Yu, Chung Y Hse, T F Shupe


Dual Borate and Copper Naphthenate Treatment of Bridge Timbers:- Potential Performance Enhancements and Cost Savings
2017 - IRG/WP 17-40797
Dual treatment technology combining diffusible preservatives with oil borne preservatives, widely used for crossties in the USA, has now also been commercialized with bridge ties/timbers. In order to understand the implications of these changes, the historic service life of creosote treated bridge timbers in northern and southeastern USA were considered as well as field test data for both creosote...
J Lloyd, C Brischke, R Bennett, A Taylor


A Green and Novel Technology for Recovering Copper and Wood from Treated Wood Waste – Part II: Optimization, copper metal recovery, and process design
2017 - IRG/WP 17-50326
The US consumes 70 million pounds of copper and produces 580 million cubic feet treated wood annually. The EPA disallows burning and reusing treated wood waste due to health/environmental concerns. Vast quantities of copper and wood are landfilled. Two safe and low cost extraction systems, citric acid and ammonium citrate, were identified in Part I of this study. In Part II of the study, effects o...
S Chen, R Patel


Response of Terminalia mantaly H. Perrier wood to beetles tunneling in Southern Nigeria
2018 - IRG/WP 18-10918
Terminalia mantaly (TM), is extremely susceptible to beetles attack, as evidenced by the many scars and/or tunnels on nearly all the trees in the Southern Nigeria. However, information on the responses of wood to insects tunnelling is poorly known for tropical species. To examine the response of TM stem wood to beetles tunnelling in the University of Port Harcourt, we scheduled field observational...
G A Adedeji, U Zakka, A A Aiyeloja, A I Ochuba


Adhesion durability of the thinnest CLT in Japan treated by solvent recovery system
2019 - IRG/WP 19-40882
The purpose of this study is to clarify the adhesion durability of the thinnest CLT (36 mm thickness) in Japan impregnated with preservatives (azole neonicotinoid compounds (AZN)) under solvent recovery system so called “dry pressure process” for long-term durability. The adhesion durability tests were conducted in accordance with the Japanese Agricultural Standard (JAS) of Cross-Laminated-Tim...
K Kawakami, W Ohmura


Alternative products enhancing dimensional stability comparing to conventional treated products in Japan
2019 - IRG/WP 19-40885
The Act on the Promotion of the Utilization of Wood in Public Buildings (2010) in Japan has made a new stream of the utilization field of timber from housing constructions to larger scale non-housing constructions. After the act, the performance of dimensional stability in preservative treated products becomes more important factor than before. Therefore, various technologies have been developed, ...
K Yamamoto, D Tezuka, Y Sugai, S Maeda, I Momohara