The dry rot fungus Serpula lacrymans. Examples of attack and remedial treatment
1988 - IRG/WP 1347
The film deals with several aspects of dry rot attack and eradication in buildings. The detailed biology and morphological charasteristics of the fungus are portrayed. The various forms of mycelial growth, the role of the strands in the nourishment and spread of the fungus, as well as the many types of fruitbody formation are outlined. Environmental and nutritional requirements of the fungus as we...
G Buchwald, B M Hegarty, W Metzner, R Pospischil, H Siegmund, P Grabow


Soft rot penetration - Effect of groundline maintenance treatment on poles in sevice
1983 - IRG/WP 3263
R S Johnstone


Water-based wood preservatives for curative treatement of insect-infested spruce constructions
1998 - IRG/WP 98-30171
On laying down sanitation measures for wooden constructions infested by wood boring insects, we must take into account static risks for the construction - and, thus, for the security of the user - as well as risks for humans and environment due to the chemical preservative compounds of the treated wood. Analyses on many roof constructions made with spruce (Picea abies L.) have revealed that Hylot...
E Graf, P Manser, B Lanz


Finite element analysis of boron diffusion in wooden poles
2003 - IRG/WP 03-40263
The problem of describing the migration of dissolved boron in wood is treated with special reference to the commonly used remedial treatment of wooden poles. The governing equations are derived and discussed together with some of the material parameters required. The equations are solved by the finite element method and finally, results showing the effect of different treatment strategies are pres...
K Krabbenhøft, P Hoffmeyer, C G Bechgaard, L Damkilde


Movement of boron from fused boron rods implanted in Southern pine, Douglas fir, red oak, and white oak timbers
1995 - IRG/WP 95-30061
This paper reports the distribution of boron from fused boron rods installed into six-inch (15.2 cm) square timbers of Douglas-fir, Southern Pine, red oak and white oak exposed aboveground. The composition and size of rods was: sodium borate and sodium borate-copper oxide (8.5 x 100 mm²); sodium borate-copper, sodium borate and boric oxide-copper oxide (12 x 76 mm²). The boric acid equivalent wa...
T L Highley, L Ferge


Fumigation as a remedial treatment: A review of North American literature
1983 - IRG/WP 3253
The development of the use of fumigants for eliminating decay in timber and roundwood in North America is reviewed. Initial experiments on oak wilt identified volatile chemicals which eradicated decay in roundwood. Subsequently, extensive experimentation on Douglas-fir poles in service showed that treatment with chloropicrin eliminated internal decay for more than ten years. Vorlex was also quite ...
J N R Ruddick


A laboratory method for assessing the effectiveness of remedial treatments in preventing post-treatment emergence of Anobium punctatum
1982 - IRG/WP 2175
R W Berry


HCB - a new preservative combination for wood pole maintenance
1996 - IRG/WP 96-30122
New combination of heavy creosoted boron (HCB) applied on hardwood and softwood logs at different moisture content revealed successful diffusion of boron in all sapwoods within 7 days and in all sapwoods plus hardwoods within 15 days. The new cost effective paste sterilizes wood through diffusion and suitable for pole maintenance at groundline and above groundline e.g. cut ends, drilled holes, woo...
A K Lahiry


Evaluation of a solid remedial wood preservative containing boron and fluorine
1993 - IRG/WP 93-30022
The fungicidal and termiticidal effectiveness of a new rod form of diffusible remedial wood preservative, containing disodium octaborate tetrahydrate/sodium fluoride and marketed as Polesaver Rod, was evaluated in laboratory tests against three species of basidiomycete fungi (Coniophora olivacea, Pycnoporus coccineus, Perenniporia tephropora) and two species of subterranean termites (Coptotermes a...
K J McCarthy, J W Creffield, L J Cookson, H Greaves


Non Toxic Remedial Treatment of Bamboo Structures/Furniture
2010 - IRG/WP 10-40516
Molds and beetles often attack bamboo furniture and structures when used in untreated or inadequate preservative treatment. Remediation or eradication of infestation often involves expensive chemicals (fumigants) and specialized methods, which are not available in villages. Novel inexpensive methods using easily available chemicals were developed for controlling such infestations. Whereas applicat...
S Kumar


Remedial treatment of joinery. Comparison of distribution of organic solvent preservative and ammonium bifluoride
1978 - IRG/WP 3115
It is some years since it was recognised in the United Kingdom that there was a problem of premature decay in untreated external joinery. Consequently, recommendations for preservative treatment were made by the Building Research Establishment, Princes Risborough Laboratory. In addition, the National House-Building Council has also included the preservative treatment of external joinery in its req...
J M Taylor


Remedial treatment of wood attacked by insects
1981 - IRG/WP 3175
A review is presented of remedial treatments against wood-boring insects in wood in service. Preconditions and fundamental principles of insect control are compared with the control of fungal attack and reasons are given for the fact that remedial treatments against insects are more commonly applied than against fungi. With regard to insect control measures with a simultaneous preventive effective...
H Kühne


Lifetime of impels in poles maintenance cycles for utility poles
2001 - IRG/WP 01-30258
In 1992-98 15.000-20.000 utility poles in Denmark received remedial treatment against decay with fused Boron-rods (IMPEL®). Economically simple, the Impel-rods are placed with the PillarTreat Method as concentrated depots in the ground-line. From there it is distributed by diffusion through the natural moisture in the wood, which ensures that it reaches moist wood in that parts of the pole where ...
A Peylo, C G Bechgaard


Performance of boron and fluoride based rods as remedial treatments in Douglas-fir poles
1995 - IRG/WP 95-30070
Boron and fluoride are widely used for remedial internal treatments, but their use in North America has been limited. Recently, however, interest in these chemicals has increased as the result of concerns about the risks of fumigant usage. The performance of boron or a boron/fluoride combination was assessed in Douglas-fir poles over 1 to 3 year periods. Both chemical formulations diffused well th...
J J Morrell, P F Schneider


Fumigant movement in Canadian wood species
1984 - IRG/WP 3296
Pole sections prepared from seven Canadian wood species (Thuja plicata, Thuja occidentalis, Pinus contorta, Pinus resinosa, Pinus banksiana, Pseudotsuga menziesii, southern yellow pine) were fumigated with chloropicrin, methylisothiocyanate and Vapam and the rates of fumigant penetration determined. All three fumigants were applied directly into holes bored radially into the pole sections. Analysi...
J N R Ruddick


A chemical and mycological evaluation of fused borate rods and a borate/glycol solution for remedial treatment of window joinery
1983 - IRG/WP 3225
The possibility of using fused borate rods (Impel Borpatron) and a borate/glycol solution (Boracol-40) for depot impregnation of window joinery has been examined in a co-operative project between The Swedish Forest Products Research Laboratory, The Swedish University of Agricultural Sciences and Prolignum AB. The fused Impel rod is a glassy rod composed of disodium octaborate which readily dissolv...
M-L Edlund, B Henningsson, A Käärik, P-E Dickèr


Interim report on the use of borate rods for the in-situ treatment of joinery
1980 - IRG/WP 3159
In the U.K. in recent years, it has been recognised that there is a major need for in-situ treatment of joinery at risk from or showing the early signs of decay. Several techniques have been developed to provide such a treatment, one of which is based on the insertion of anhydrous borate glass rods. The tests in hand are long term and this report is confined to the mycological isolation data from ...
D J Dickinson


Occupant re-entry times following insecticidal remedial treatments of timber in dwellings
1995 - IRG/WP 95-50055
This work was carried out principally to obtain quantitative data on the aerial concentrations of permethrin and white spirit likely to arise following the remedial treatment of timber in buildings, using insecticidal formulations. Such data are needed to allow assessments to be made of the length of time buildings should remain unoccupied following such treatments prior to re-occupation, and the ...
R J Orsler, G E Holland, G M F Van Eetvelde


Remedial ground-line treatment of CCA poles in service. Results of chemical and microbiological analyses 6 months after treatment
1986 - IRG/WP 3388
CCA-treated poles in service with incipient internal soft rot were remedially treated by inserting borate rods, brushing with a boron/glycol solution and injecting boric acid paste, copper/creosote paste or a commercial product (DFCK paste). The spread of active chemicals in the treated zone as well as the change in microflora have been studied with time. After six months chemicals had spread to m...
B Henningsson, H Friis-Hansen, A Käärik, M-L Edlund


Bait box technique for remedial subterranean termite contro
1995 - IRG/WP 95-10115
The bait box technique, as described in this paper, was first used as a method to apply the dust toxicant, arsenic trioxide, to large numbers of aggregated subterranean termites. Over the last twelve years or so the technique has been refined, and in recent years, gained acceptance as an alternative subterranean termite control measure by members of the Australian pest control industry. This baiti...
J R J French, B M Ahmed, D M Ewart


Remedial ground-line treatment of CCA poles in service. A final report after 60 months' testing
1989 - IRG/WP 3534
Remedial treatment of CCA treated utility poles of Pinus sylvestris with incipient decay was carried out in 1983 and the results of chemical and microbiological analyses 6 months after treatment were reported in Document No: IRG/WP/3388 while microbiological studies 12 and 28 months after treatment as well as chemical analyses of poles treated with boron rods or boric acid paste 28 months after tr...
B Henningsson, H Friis-Hansen, A Käärik, M-L Edlund


Development of a model system to assess the efficacy and environmental impact of a chromated fluoride remedial treatment for creosoted distribution poles
1992 - IRG/WP 92-2395
A closed model system was designed to facilitate a controlled study of the leachability and environmental fate of a remedial preservative under laboratory conditions. The elements of the model include a precipitation apparatus above a treated pole section which is positioned in a representative soil profile supporting a sward of perennial ryegrass. The model will allow detailed examination of the ...
D C R Sinclair, G M Smith, A Bruce, B King


Preservative treatment of common timbers and bamboos of Bangladesh for rural electrification infrastructure
1998 - IRG/WP 98-40104
Researches revealed new treatment grades, treatment groups, grading groups, natural durability grades, strength groups and a new preservative combination for remedial treatment and sterilization of most common timbers and bamboos of Bangladesh. The obtained findings are applicable for equivalent timber species having equivalent climatic condition. Sapwoods are always perishable and timbers with wh...
A K Lahiry


Remedial treatment of creosoted railway sleepers of redwood by selective application of boric acid
1980 - IRG/WP 3134
An ideal preservative for remedial treatment must primarily be characterized by two requirements. First, it must have an ability to diffuse and distribut evenly into the wood and secondly, it must be fixed properly so that it does not leach out too fast. However, these two characteristics conflict with each other, and the choice of preservative must of necessity be a compromise. Wood preservatives...
C Bechgaard, L Borup, B Henningsson, J Jermer


Remedial ground-line treatment of CCA poles in service. A progress report after 28 months' testing
1988 - IRG/WP 3481
Remedial treatments of CCA-treated poles in service with incipient soft rot were carried out with boron rods, boron/glycol solution, boric acid paste, copper/creosote paste and a commercial product (DFCK paste) respectively. The micro-flora before remedial treatment and 6 months after as well as the spread of chemicals in the poles were reported in Document No: IRG/WP/3388. In this progress report...
B Henningsson, H Friis-Hansen, A Käärik, M-L Edlund