Your search resulted in 173 documents. Displaying 25 entries per page.
Safety technique in wood preservation
1974 - IRG/WP 54
S N Gorshin, I G Krapivina, B I Telryatnikova
A deflection test for monitoring decay in miniature beams
1986 - IRG/WP 2269
A laboratory apparatus for assessing decay in small stakes is described. It involves the measurement of deflection in a static bending apparatus using a displacement transducer linked to a microcomputer. Measurements are non-destructive, rapid, accurate and automatic and decay can be assessed repeatedly over long time periods....
S M Gray
Wood preservatives ecotoxicology on Gammarus pulex (L.) - toward an environmental monitoring method and a getting rid of pollution process
2005 - IRG/WP 05-50224-9
Wood preservatives can have a strong impact on freshwater invertebrates when used close to aquatic ecosystems. It has been reported in Jura that different arthropod taxa, specially crustaceans, have disappeared along several kilometers downstream from factories using insecticides and fungicides as wood preservatives.
The crustacean Gammarus pulex (L.) is a relevant bioindicator to characterize th...
O Adam, F Degiorgi, G Crini, P-M Badot
Framework document for an international code of good practices for wood preservation and wood protection (anti-sapstain) facilities
1992 - IRG/WP 92-3683
At the Kyoto meeting, the Health & Safety committee agreed to form a task force to prepare a global plan for writing a code of good practices (Code) for wood protection and preservation facilities (Doc. No. IRG/WP/3681). The Canadian document had been presented to the IRG group earlier (Doc. No. IRG/WP/3447) and similar documents were solicited from other countries for preparing a framework do...
V N P Mathur, G Das
Proposal for further work on environmental questions
1988 - IRG/WP 3494
Although very much is known about the environmental and health and safety aspects on various wood preservatives and treated wood knowledge is still lacking on some important issues. Some examples are: - The fate of wood preservatives in the environment, eg by leaching from treated wood and contaminated soil; - How big is the "problem" of pollution, etc from the wood preserving industry in comparis...
J Jermer, M-L Edlund
Dioxin, an emotive word
1980 - IRG/WP 3156
J David
Field trials on preserved timber out of ground contact
1978 - IRG/WP 3154
This report describes two different field trials studying the performance of preservative treatments on timber exposed to the weather, but above the ground. Results are presented on the protection afforded against decay, and on the efficiency of water-repellent preservative treatments in controlling the uptake of moisture by the timber. Proposals for a standard field test system are briefly discus...
D F Purslow, N A Williams
Chlorodioxines dans le pentachlorophénol
1975 - IRG/WP 346
H Alliot
The development of a screening method for the activity of pyrethroids against wood boring marine crustaceans, Limnoria spp
1978 - IRG/WP 443
The present work is concerned with the develepment of a suitable bio-assay technique to determine the biological activity (contact action) of pyrethroids against Limnoria spp. Estimates of the toxicity of three pyrethroids, permethrin, cypermethrin and decamethrin (the structures of which are shown in Fig. 1.) to the marine borer have been obtained....
D Rutherford, R C Reay, M G Ford
Technique for monitoring absorption during a vacuum pressure process
1992 - IRG/WP 92-3696
A laboratory technique was developed and an apparatus constructed which allowed for the direct and continuous measurement and observation of volumetric uptake of water-borne preservative into wood samples throughout a controlled vacuum-pressure treatment process. Fractional filling of void space was calculated. Graphing (fractional saturation) against time allows prediction of optimum cycle length...
A J Pendlebury, J A Petty
Studies on the preservation of structrual plywood - Part 1: Decay resistance of structural plywood
1974 - IRG/WP 238
The weight loss and the decreases in the compression strength and in the modulus of elasticity were measured to determine the decay resistance of structural plywood (lauan). Test pieces (50x25xA mm³) were exposed to the wood destroying fungi (Coriolus versicolor and Coriolellus palustris) for 2-3 or 2-4 months. After exposure, the measurement of the compression strength was carried out on the pie...
K Minami, Y Kenjo, S Sugiyama
Thirty-four year test of on-site preservative treatments to control decay in wood above ground
1993 - IRG/WP 93-30015
This research was initiated in 1958 to investigate efficacy of various preservatives and treating methods for new lumber going into exterior structures of buildings. Post-rail units (2x4 inches) constructed of Southern Pine sapwood, Douglas-fir heartwood, and mill run western hemlock were dip- or brush-treated before or after assembly. Units were trested with pentachlorophenol in various petroleum...
T L Highley, T C Scheffer
Safety clearance of wood preservatives in United Kingdom
1977 - IRG/WP 398
In the United Kingdom the principal route of control of pesticides is through the Pesticides Safety Precautions Scheme (PSPS) which is a non-statutory scheme agreed between government ministries and departments (referred to as "Departments") and associations representing the pesticide industries. The scheme formally began in 1957 covering those pesticides and related substances used in agriculture...
J M Baker
Traitement curatif des bois en place. Hygiène et sécurité
1990 - IRG/WP 3585
P Huré
Questionnaire on the state of pollution control in the field of wood preservation
1974 - IRG/WP 52
H Willeitner
Health and safety aspects of the use of wood preservatives. Preliminary evaluation of the answers to the IRG-Questionnaire on the state of pollution control in the field of wood preservation
1974 - IRG/WP 56
This preliminary evaluation of the answers to the IRG/WP-Questionnaire only gives a general survey on those questionnaires, which the author received until June 13, 1974. Details, such as correlations between importance of wood preservation and pollution control, could not be considered due to lack of time. For the same reason it was not possible so far, to evaluate the additional remarks given in...
H Willeitner
Assessment of wood preservation facilities in Canada
1989 - IRG/WP 3557
This document sets out an assessment procedure for the current status of the wood preservation industry in Canada in relation to the Technical Recommendations (TR) documents for the Design and Operation of Wood Preservation Facilities published by the Government of Canada in April 1988. A questionnaire has been prepared in consultation with industry and the Canadian Institute of Treated Wood. An a...
G Das, V N P Mathur
Preservatives treatment and field test monitoring of spruce pole stock: CCA and fumigant treatments
1990 - IRG/WP 3619
The fumigants trichloronitromethane (chloropicrin) and sodium N-methyldithiocarbamate (SNMDC) were used to treat red spruce pole stock, either CCA treated or untreated, through holes bored through the pole's center. The poles were analyzed for the presence of microorganisms immediately before ground installation and again after installation at a pole test site. Monitoring of fumigant move...
A J Pendlebury, B Goodell
Justification for use of mirex in termite control
1988 - IRG/WP 1346
In August 1987, organochlorines were withdrawn in North America from use in termite control. This has left the industry and the community with reduced options in long term protection of wood and wood products. A case is presented to justify the use of the slow-acting stomach termiticide, mirex, under special permit, for use only in the bait-block method of termite control. This method, while not a...
J R J French
Current models used by the European Health Authorities to evaluate the volatilization of active ingredients from treated wood used inside dwellings. A case study: Volatilization of azaconazole and propiconazole from treated wood
1990 - IRG/WP 3565
The use of wood preservatives inside houses may result in measurable aerial concentrations of active ingredients. These airborne contaminants may be inhaled by the inhabitants over periods lasting from a couple of days to several months. To assess the potential health hazard of preservative residues in the air, various risk-assessment models have been worked out. Three schemes, currently used by t...
A R Valcke, L Van Leemput
Wood preservation in Kenya
2000 - IRG/WP 00-40191
Current research on wood preservation in Kenya is mainly on the development of biological control of wood-destroying termite species, using mycoinsecticides. The major research institutions include the Kenya Agricultural Research Institute (KARI), Kenya Forestry Research Institute (KEFRI), Moi University and the International Centre for Insect Physiology (ICIPE). Training institutions include Fore...
G Ochiel
Feasibility of termite control using crushed cement-stabilized sludge (Polynite) as a physical barrier and acoustic emission (AE) monitoring
2000 - IRG/WP 00-10381
In Japan, the damages by the subterranean termites (Coptotermes formosanus Shiraki and Reticulitermes speratus Kolbe) are more common. Recently, the more attention is paid to the methods of the termite controls of less- or non-chemical. As one of the non- chemical treatment, physical barrier using particles as basalts 1) , granites, and gravels 2) were investigated in terms of its safety, cost eff...
Y Yanase, M Shibata, Y Fujii, S Okumura, K Iwamoto, T Nogiwa, T Yoshimura, Y Imamura
Feasibility of AE (Acoustic Emission) monitoring for the detection of the activities of wood-destroying insects
1992 - IRG/WP 92-2416
The feasibility of acoustic emission (AE) as a nondestructive testing method for the detection of the wood destroying insects was investigated. AEs were detected from the wood specimens under feeding attack of sugi bark borers or powder-post beetles. However, the feasible monitoring area of an AE sensor is influenced by the attenuation of AE amplitude, so that this could be a problem in the practi...
Y Fujii, Y Imamura, E Shibata, M Noguchi
Detection of Acoustic Emission (AE) generated by termite attack in a wooden house
1999 - IRG/WP 99-20166
Recently, considerable attention has been paid to methods for termite control, which involves few or no chemicals. To reduce the amount of termiticide needed, it is necessary to detect termite attack in wood as early as possible. The feasibility of acoustic emission (AE) monitoring for the nondestructive detection of termite attack has been discussed previously. In this study, we propose some tech...
Y Fujii, Y Yanase, T Yoshimura, Y Imamura, S Okumura, M Kozaki
Second international symposium on wood preservation "The challenge safety-environment" 8-9 February 1993, Cannes-Mandelieu, France
1993 - IRG/WP 93-50001
Contains the following 34 Documents (IRG/WP 93-50001/1 - IRG/WP 93-50001/34) and 4 abstracts:
A methodology for the life-cycle assessment of treated timber products (IRG/WP 93-50001/1)
Initial results and observations of a model system to assess the efficacy and environmetal impact of preservative treated wood (IRG/WP 93-50001/2)
Borates as wood preservatives - an environmental, health and safe...
Anonymous