IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 888 documents. Displaying 25 entries per page.


Response of laboratory groups of Reticulitermes speratus (Kolbe) to different quantities of food
2003 - IRG/WP 03-10489
As part of a project aimed at improving understanding of the foraging biology of Japan’s most widespread wood-destroying termite, different sized groups of Reticulitermes speratus (0.5; 1 and 2 g) from two colonies were kept on 16 or 64 cm3 of sapwood of Cryptomeria japonica for 12 weeks in the laboratory. Patterns of wood consumption, wood consumption rates and survival are discussed....
M Lenz, T Yoshimura, K Tsunoda


Termite standards questionnaire survey
1987 - IRG/WP 1324
J R J French, J P La Fage


Treatment of Douglas fir heartwood with disodium octaborate tetrahydrate (Tim-BorÒ ) to prevent attack by the Formosan subterranean termite
1991 - IRG/WP 1487
Toxicity of disodium octaborate tetrahydrate (Tim-BorÒ) to Coptotermes formosanus Shiraki (Isoptera: Rhinotermitidae), and termite feeding on treated Douglas-fir heartwood were evaluated in laboratory and field tests. Feeding on filter papers impregnated with Tim-BorÒ solutions reduced but did not eliminate termite gut protozoan populations. In a forced-feeding laboratory assay, Douglas-fir hear...
M Tamashiro, R T Yamamoto, J K Grace


Biocides - Efficacy assessment and doses for wood preservatives (product type 8). Local/geographical aspects. Termite control as case study
1999 - IRG/WP 99-20181
Currently, the efficacy of a wood preservative, as biocidal product type 8, is assessed as a ‚critical value' (CV), an efficient dose (retention in wood at a given depth of penetration). CVs are planned to be adapted for exposure to basic target organisms (5 hazard classes) and additional requirements concerning the occurrence of local target organisms in relation with climate, building...
G Ozanne


Development of a Granitgard® particulate termite barrier for use in tropical Australia
1997 - IRG/WP 97-10190
Granitgard® is superficially simple technology; graded crushed aggregate, sieved to a size range impenetrable to subterranean termites. However, behind this apparent simplicity lies a large research effort. In this paper we describe the laboratory development of a grading of Granitgard suitable for use against the wide range of termites which attack timber in northern Australia, above the Tropic ...
D M Ewart, E R Rawlinson, A D Tolsma, G C Irvin, P R Wiggins


Volatile borates in the treatment of wood and wood based panel products against subterranean termites
1995 - IRG/WP 95-30094
Blocks of pine solid wood, oriented strand board and plywood were treated with trimethyl borate by vapour treatment. It was meant to obtain either a full impregnation of the specimens or a shell treatment of the outer three millimetres. The efficacy of the treatments against subterranean termites (Reticulitermes lucifugus) was evaluated using an European Standard method....
L Nunes, D J Dickinson, R J Murphy


Evaluation by experimentation on site of a new method for termite control
1996 - IRG/WP 96-10173
A new concept of subterranean termite control consists of the installation of toxic baits in or around the infested construction. Dow Elanco has developed a bait system based on Hexaflumuron. This active ingredient is an insect growth regulator with slow acting effect. A lot of trials were conducted in the USA, but none in France until now. We realised on site experiments, in order to estimate the...
A-M Pruvost, M-M Serment, M Jéquel


A critical review of the AWPA standard method (M12-72) for laboratory evaluation to determine resistance to subterranean termites
1986 - IRG/WP 1298
The American Wood Preservers' Association standard (M12-72) for evaluation of candidate wood preservatives against subterranean termites is reviewed and suggestions for revision are made. The most serious flaws in the current test procedure involve a failure to recognize inter- and intraspecific variation and a lack of quantification of test results....
J P La Fage, M Jones


Screening potential termiticides: Some thoughts and suggestions on methodology
1988 - IRG/WP 1363
While laboratory bioassays on the efficacy of potential termiticides against subterranean termites continues both to dominate and influence research efforts, suggestions are presented for the need to develop laboratory bioassays that more closely simulate "natural conditions". Not only is this considered desirable, but it will offer more confidence in laboratory and field evaluations and their ana...
J R J French


Geographical distribution of termites inside buildings in France
1991 - IRG/WP 1512
Since several years, data concerning infestations of buildings by termites are collected by CTBA. Most of them come from of the localizations communicated by the Pest Control Operators in the frame of the Approval. Maps were settled in 1975, 1981 and lastly in 1989. These maps show that the areas infested by termites are extending. Processing of data is described....
M-M Serment, A-M Pruvost


The influence of boric acid on respiratory quotients and methane production of subterranean termites
1995 - IRG/WP 95-10136
The toxicity of boron compounds to subterranean termites (Reticulitermes lucifugus) was studied by analysing changes in the levels of oxygen uptake respiratory quotients and methane production. Termites were fed with filter paper treated at different levels of boric acid, the RQ was evaluated by constant volume manometry and the methane production by gas chromatography. Results are discussed in re...
L Nunes, D J Dickinson


Tunneling ability of subterranean termites through termiticide-treated soil
1988 - IRG/WP 1375
A test apparatus was designed to facilitate accurate measurement of termite penetration into termiticide-treated soil; three termiticides at 500 ppm were evaluated. Coptotermes formosanus Shiraki workers tunneled significantly farther into chlordane-treated soil than did Reticulitermes flavipes (Kollar). Both species only slightly penetrated chlorpyrifos-treated soil. Neither species penetrated so...
S C Jones


Field testing of soil insecticides as termiticides
1986 - IRG/WP 1294
This paper reviews field methods used to evaluate soil insecticides as termiticides by the U.S. Department of Agriculture, Forest Service, Gulfport, Mississippi. Field tests are conducted on a minimum of five "nationwide sites" in the United States to determine the efficacy of chemicals in various soil types and against different termite species. Test results of selected insecticides are presented...
R H Beal


Wood preservation in Kenya
2000 - IRG/WP 00-40191
Current research on wood preservation in Kenya is mainly on the development of biological control of wood-destroying termite species, using mycoinsecticides. The major research institutions include the Kenya Agricultural Research Institute (KARI), Kenya Forestry Research Institute (KEFRI), Moi University and the International Centre for Insect Physiology (ICIPE). Training institutions include Fore...
G Ochiel


Envelope treatment to protect softwood timbers from damage by subterranean termites
2003 - IRG/WP 03-30313
Two aboveground field trials were conducted in Australia to determine the effectiveness of envelope treatments of deltamethrin and permethrin for the protection of softwood framing timbers against termite damage. Radiata pine Pinus radiata D.Don and slash pine Pinus elliottii Englem., were treated with Tanalithä T (a novel solvent) to achieve 5-mm-depth envelopes. Details of a field trial against...
B C Peters, J W Creffield


A baiting technique to monitor the development and control of decay in transmission poles
1981 - IRG/WP 2149
P I Morris, D J Dickinson


Effects of methoprene on Coptotermes formosanus (Isoptera: Rhinotermitidae)
1987 - IRG/WP 1322
Methoprene affected differentiation and survival of Coptotermes formosanus Shiraki in laboratory studies. At 5, 9, 13, and 17 weeks, superfluous intercastes and presoldiers were produced when termites were allowed to feed on concentrations of 1,000 and 2,000 ppm methoprene in wood blocks. Colony numbers were significantly reduced after 13 and 17 weeks of exposure to the insect growth regulator. Te...
S C Jones


A case for adopting a standardised protocol of field and laboratory bioassays to evaluate a potential soil termiticide
2003 - IRG/WP 03-20275
The rationale for adopting a new approach to the field testing of potential soil termiticides is advocated on the grounds that current testing methods are limited to termite bioassays and do not address quantitatively the persistence and bioavailability of soil termiticides to foraging subterranean termites over time and in different soil types. Furthermore, the present testing regimes assume fiel...
J R J French, B M Ahmed


Wood-destroying Rhinotermitidae (Isoptera) in the oriental region
1984 - IRG/WP 1236
Species of the family Rhinotermitidae are important wood-destroying termites. From the Oriental zoogeographical region, 85 species of the family are reported of which some are wide spread and cause extensive damage to wood, wooden articles and other cellulosic products. The distribution, biology, ecology and pest status of the important wood-destroying species, in the Oriental region, are given in...
O B Chhotani


Susceptibility of softwood bait stakes to attack by subterranean termites (Isoptera: Rhinotermitidae)
1994 - IRG/WP 94-20037
Sapwood stakes of Australian-grown Araucaria cunninghamii (hoop pine), Pinus elliotii (slash pine), Pinus radiata (radiata pine) and North American-grown Pinus sp. (southern yellow pine) were exposed to subterranean termite attack in an in-ground bioassay. Stakes in bait containers and bare stakes were attacked by Coptotermes acinaciformis and Schedorhinotermes intermedius. Basic susceptibility of...
B C Peters, R T Murray, C J Fitzgerald


An overview of termite control in buildings in Kenya
1997 - IRG/WP 97-10242
Termites are well known pests of wooden products and structural timber and are responsible for considerable damage in the building sector in sub-Saharan Africa. A general diagnostic survey of damaging termite species in agriculture, forestry and buildings was carried out for the first time in Kenya (1991-1992). Termite species implicated in damage to wooden materials and structural timber in build...
G R S Ochiel, W Gitonga, L Toft


Termite standards questionnaire survey - First Report
1988 - IRG/WP 1354
Information contained in replies received from IRG members responding to the termite standards questionnaire survey are summarised. Highlighted in the results of this first report are the major termite species in the various zoogeographical regions, their damage ranking to timber-in-service, the chemicals used in control methods, and the status of termite standards in the respondent countries....
J R J French, J P La Fage


On the possibilities of the use of juvenile hormone analogues (JHAs) in termite control. (A preliminary note for information)
1983 - IRG/WP 1214
A T De Lelis


Questionnaire on the most important wood-destroying insects in your country and/or state
1980 - IRG/WP 1125
S Cymorek


Damage by wood-attacking insects in buildings in Sao Paulo State - Brazil. (including errata slip)
1978 - IRG/WP 175
From 1974 to 1978 up to 602 buildings attacked by wood-boring insects were inspected by Instituto de Pesquisas Tecnologicas in Sao Paulo State - Brazil. Damage was caused mainly by subterranean termites, dry-wood termites and wood-attacking beetles. Up to US $ 1000,000 is the amount needed to control such insects in the buildings inspected...
A T De Lelis


Previous Page | Next Page