Your search resulted in 838 documents. Displaying 25 entries per page.
Acceleration of boric acid uptake into the subterranean termite, Coptotermes formosanus Shiraki using steamed larch wood
2000 - IRG/WP 00-10353
Laboratory tests were done to measure the efficacy of addition of steamed larch (Larix leptolepis (Sieb. et Zucc.) Gord.) heartwood extracts for the uptake of boric acid against the termite, Coptotermes formosanus Shiraki. Paper discs were treated with the water-soluble fraction obtained from hot-water extracts of steamed larch wood (S-Water) with or without 0.01-2.0% boric acid, followed by expos...
W Ohmura, S Doi, S Ohara
Is laboratory testing of decay resistance questionable as a single criterion for natural durability?
1996 - IRG/WP 96-20096
In a laboratory test set up over 20 hardwood species were evaluated according to the European Standard EN 350-1 including Basidiomycete and soft rot testing. Half of the species used were of a known natural durability. The Basidiomycete testing was carried out using Coriolus versicolor, Gloeophyllum trabeum and Coniophora puteana in a malt agar test similar to EN 113. From this test it was not pos...
J Van Acker, M Stevens, T Van Cauwenberghe, T Seynaeve
Bestimmung der pilzwidrigen Wirksamkeit von Holzschutzmitteln gegen Moderfäule-Erreger
1977 - IRG/WP 2125
Ziel der vorliegenden Arbeit war der Vergleich der in verschiedenen Ländern zur Bestimmung der pilzwidrigen Wirksamkeit von Holzschutzmitteln gegen Moderfäule-Erreger angewandten Methoden. Als Vergleichsmaterial dienten drei normierte Methoden: die britische (42), skandinavische (45) und die in der DDR angewendete (47) sowie wichtige, von verschiedenen Fachleuten ausgeführte Arbeiten experiment...
J Wazny
Rainfall simulation to assess CCA permanence
1991 - IRG/WP 2373
During experimental work on accelerated fixation of chromium containing preservatives a method has been developed which compares the degree of preservative levels of contamination of simulated preservative fixation in timber with the levels of simulated rainfall. This method uses commercial sized wood sections wetted in a way that simulates actual rainfall and relates the associated run-off contam...
P Warburton, J A Cornfield
Screening techniques for potential wood preservative chemicals. Proceedings of a special seminar held in association with the 10th Annual Meeting of the IRG, Peebles 1978. Report No 136, 1979
1980 - IRG/WP 2138
This paper continues following issues:
I. SCREENING INSECTICIDES
1) R W Berry (BRE/PRL, UK): Screen testing of insecticides for use in remedial wood preservatives.
2) D J Cross (FRI, New Zealand): Rapid screening of contact insecticides for use on forest products.
3) C R Coggins; A Forsyth; A E Glaser (Rentokil, UK): Experience in the use of indicative screening techniques for termiticides.
...
Anonymous
Laboratory tests on the natural durability of timber methods and problems
1984 - IRG/WP 2217
In literature a large variety of test methods is mentioned to examine the natural resistance of timber against fungal attack. This concerns the kind of sampling as well as the test procedure, the test fungi, the duration of test, and the classification of the resistance according to the test results. These variations, however, are of great influence on the test result. Long term exposure will lead...
H Willeitner
A preliminary assessment of the costs of termite activity in Australia: A discussion paper
1983 - IRG/WP 1207
A preliminary assessment has been made of the economic importance of termite activity in Australia and this paper is intended to serve as a starting point in discussing this topic. Damage to timber in service represents their greatest area of economic importance in urban and rural environments. Costs resulting from termite activity include timber replacements in buildings, railway sleepers, transm...
J R J French
The performance of metal-chromium-arsenic formulations after 32 to 38 years' in-ground exposure in Australia
2000 - IRG/WP 00-30240
Two trials of metal-chromium-arsenic preservatives were exposed in-ground in Australia. In Trial 1, Pinus radiata stakes treated with Boliden K.33, Boliden S.25, Celcure A, Tanalith C and Tanalith CA were installed at Sydney and Narrandera in 1961/1962. In Trial 2, P. radiata and Eucalyptus regnans sapwood were treated with Celcure A, Celcure A21-N, Celcure A 21-O and Tanalith CA (new) and install...
G C Johnson, J D Thornton, J Beesley
Field and greenhouse testing of window joinery of pine and spruce treated with LOSP
1991 - IRG/WP 3658
Norwegian window frame components of full size were double vacuum-treated with TBTN and TBTO, and connected as 'L-joints' and subsequently coated with stains. The corner sections were exposed (out of ground contact) both in field (temperated coastal climate, Taastrup, Denmark) and in a greenhouse (Uppsala, Sweden). The window frame L-joints of spruce (Picea abies Karst.) - treate...
F G Evans, B Henningsson, E Borsholt
Intraspecific variability in feeding capacity of Coptotermes acinaciformis (Froggatt) (Isoptera: Rhinotermitidae)
1983 - IRG/WP 1175
This paper describes laboratory studies to evaluate the comparative feeding capacity within and between five mound colonies of Coptotermes acinaciformis (Froggatt). Matched specimens of mountain ash, pine and coachwood were exposed to five replicate 10 g groups of termites from each colony source. After an initial 8-week exposure period, all groups were assessed for vitality and continued feeding ...
C D Howick, J W Creffield
A dynamic approach to assess the modulus of elasticity in wood decay testing
1998 - IRG/WP 98-20139
In this study, the changes in elastic behaviour and mass losses of different hardwood and softwood species exposed to decay in a laboratory soil tests were assessed. Wood decay was monitored using different assessment methods, namely: mass loss and changes in elastic behaviours (MOE) determination. Elastic changes were determined by static and dynamic methods, for the latter, acoustic technique wa...
L Machek, H Militz, R Sierra-Alvarez
Blue stain in timber in service. Results of further IRG collaborative tests to compare different artificial weathering systems
1981 - IRG/WP 2146
The previous work described in Document No IRG/WP/286 examined 3 preservatives (1% phenyl mercury succinate - PMS, 5% pentachlorophenol - PCP and 1.5% Preventol A4 - PA4) subjected to 5 different artificial weathering systems (BAM Xenotest, Cuprinol Marr, EMPA Xenotest, Gori Atlas and PRL Marr) and after natural weathering at 5 sites (BAM, Cuprinol, EMPA, Gori and PRL). Results showed good correla...
A F Bravery, D J Dickinson
Performance of different treatments and finishes on wood out of ground contact. Preliminary results
1984 - IRG/WP 2221
Pinus and Eucalyptus L-joints treated with CCA, a water dispersable PCP and untreated ones were painted according to seven different finish's schedules and exposed at two sites in State of Sao Paulo. After ten months of exposure, it was possible to verify that preservative treatment improve the performance of both wood and finish. It was also possible to observe that wood substrate, prese...
S Milano
Practical applications of steamed larch wood to a termite bait system using chlorfluazuron
2003 - IRG/WP 03-10464
Less chemical strategies are required for decrease of damages to residents from chemicals such as organic phosphates and carbamates those are usually used to prevent termite attacks on wooden buildings. One of the strategies is a bait system that has already been employed in the termite-infested areas. We tried to use steamed larch wood as a monitor wood and a bait matrix to stimulate feeding acti...
S Doi, S Shibutani, K Hanada, T Miyahara
Laboratory evaluation of copper naphthenate pressure treatments against the Formosan subterranean termite
1993 - IRG/WP 93-10005
Southern pine wafers and Douglas-fir cubes pressure treated with copper naphthenate in AWPA P9 Type A oil or in toluene were evaluated for resistance to attack by the Formosan subterranean termite, Coptotermes formosanus Shiraki (Isoptera: Rhinotermitidae). Wood samples were pressure treated to target copper retentions of 0.040, 0.075, 0.095, or 0.150 pcf, conditioned to simulate field exposure, a...
J K Grace, R T Yamamoto, P E Laks
Subterranean termite attack potential in field test sites: assessment methods and field characterization
2003 - IRG/WP 03-10472
To assess subterranean termite attack potential in the field and seasonal variations, trials were set up in each of two managed silvicultural plantations, of Eucalyptus globulus and Pinus pinaster, respectively. Termite occupancy in lying dead wood was evaluated by an adaptation of the line-intersection method, and attack potential in soil was assessed by a system of stakes inserted into the groun...
T Nobre, L Nunes, L Brinca, D E Bignell
Effect of soil type and moisture content on soft rot testin
1986 - IRG/WP 2270
Several soils of different types were tested at a range of moisture contents for their suitability for use in a soil burial soft rot test. Their effectiveness was assessed by weight loss in CCA treated and untreated beech and birch outerwood. A horticultural loam (John Innes No. 2) was the most appropriare soil in terms of amount of weight loss caused, tolerance to changes in soil moisture content...
S M Gray
Xylophene AS™, the challenge of developing a modern antisapstain formulation for the french market
2000 - IRG/WP 00-30250
In France Sodium Pentachlorophenol (NaPCP) has been used for more than 40 years for the protection of freshly cut and unseasoned lumber. The French sawmill industry requires a protection of 6 months and maximum 10% surface infection by moulds and/or sapstain fungi. However, this active substance did have some serious environmental flaws and no authorisation was granted for a direct contact of NaPC...
E Wozniak, L Cubizolles, N Delourme Fonseca, A R Valcke, J Gors
Prevention of Termite Tubing Over Non-Wood Construction Materials Using Glycol Borate
2004 - IRG/WP 04-30358
Glycol borates have been demonstrated to prevent termite tubing and attack of wood materials and are extensively used as termite preventative applications in new construction in the USA. This study evaluated the ability of such systems to prevent Formosan subterranean termite tubing over non-wood materials. Concrete was selected as a common inert construction material and tests were carried out ...
W R Smith, J D Lloyd
Test methods for wood preservatives against Lyctus: (1) Testing of treated veneer. (2) Testing of glue-line treated plywood. (Laboratory methods)
1977 - IRG/WP 293
Powder-post beetles destroy large quantities of veneer and plywood. Two test procedures are described which can be used to support application-oriented research into veneer and plywood preservatives. These procedures simulate practical conditions on a laboratory scale. Their characteristic feature is that wood species of special susceptibility are used for the tests; the susceptibility of the spec...
S Cymorek
Ability of an acoustic inspection device to detect internal voids
in untreated pole sections
2002 - IRG/WP 02-20246
Detecting deterioration before substantial losses in material properties occur poses a major challenge to most wood users. While physical inspection techniques such as drilling or coring are useful, these methods can miss small pockets of damage and they lack the ability to detect early or incipient decay. The development of sonic test methodologies has created the potential for detecting change...
J J Morrell, R G Rhatigan
Laboratory evaluation of six commercial termiticides against subterranean termite, Coptotermes gestroi Wasmann
1994 - IRG/WP 94-30034
Small specimens of Heavea brasiliensis (10 x 10 x 20 mm³) were exposed to the laboratory colony of Coptotermes gestroi Wasmann for 4 months after dip- or brush-treatment with six commercially available emulsifiable termiticides (alpha-cypermethrin, cypermethrin, permethrin, bifenthrin, chlorpyrifos and chlordane). Synthetic pyrethroids and chlorpyrifos were effective as well as 1% treatment of ch...
Y Sornnuwat, C Vongkaluang, T Yoshimura, K Tsunoda, M Takahashi
Interim balance after 20 months of lap-joint exposure
1999 - IRG/WP 99-20164
The application of natural resins and integrated resin systems to improve the performance of Pinus sylvestris was assessed in a lap-joint test according to DIN V ENV 12037 (1996). Lap-joints of Pinus sapwood were exposed at the test field in Hamburg (Germany) in May 1997. The treated lap-joints were assessed with regard to the performance of the resin treatments out of ground. The exposure of lap-...
M Sailer, A O Rapp, R-D Peek, A J Nurmi, E P J Beckers
Comparison of performance of wood preservatives in laboratory and field tests of treated commodities
1993 - IRG/WP 93-20010
The purpose of laboratory tests for evaluating efficacy of wood preservatives is usually to establish toxic values against standard strains of wood decay fungi. Exposure conditions are usually chosen as optimal for fungal growth. Toxic values so determined serve as a guide as to expected performance of the preservative in field stake tests or in above ground exposure tests. Test material is select...
M E Hedley
Non-destructive detection of the presence and behaviour patterns of wood-destroying insects
1988 - IRG/WP 2302
An apparatus, designed for the automatic recognition of the presence and of specific behaviour patterns of wood-boring insects, is introduced. From a wood sample, a mixture of noise and action induced substratum vibrations is picked up, amplified, filtered and translated into a sequence of computer-readable numbers which are passed to a microcomputer-based signal-pattern-recognition. If an incomin...
M Pallaske