IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 327 documents. Displaying 25 entries per page.


Fungus cellar testing as an evaluation method for performance of treated timber in ground contact
2001 - IRG/WP 01-20227
A fungus cellar method for the accelerated evaluation of performance of treated wood in ground contact is described. The test soil comprised of sandy loam, vermiculite and Japanese horticulture soil "Kanumatsuchi" in a ratio of 6:2:2 by volume. The soil was inoculated with the dominant test fungus isolated with selective medium from decayed wood samples. Pairs of treated and untreated wood specime...
Y Nagano


Detection and estimation of Hylotrupes bajulus L. wood damages by ultrasonics
1990 - IRG/WP 2350
To evaluate the validity of the ultrasonic application in the detection and evaluation of wood damages produced by Hylotrupes bajulus L. larvae, some laboratory tests were made with small wood samples. The pulse through transmission method was used. The transit time of ultrasonic pulses in transversal sections, radial and tangential, of the samples was measured. The increment of the transit time o...
G Prieto


Evaluation of tropical wood by-products as a potential source for termite control products
2001 - IRG/WP 01-10408
Termites damaging in houses represent an ever growing threat in Europe, where the phenomenon has accelerated during the last ten years, as well as in the tropics, where infestations are permanent. To fight against this plague, the current methods used, through injection of organochloric or organophosphorized products into the timber structures and walls, are belonging to the past due to the toxici...
A Zaremski, S Robert, J-L Clement, D Fouquet


Evaluation of decay fungi in Norwegian buildings
2005 - IRG/WP 05-10562
During a period of 2 years and 3 months (1 January 2001 - 20 March 2003) Mycoteam had 3161 consultations in buildings in southern Norway, 1428 revealing damage from decay fungi. One consultation often revealed several occurrences of fungi, and the total number of occurrences of decay fungi was 3434. Thirty-five different species/genera/groups of decay fungi were recorded. During this period brown ...
G Alfredsen, H Solheim, K Mohn Jenssen


Non-destructive evaluation of termite and decay damaged to timber-in- service
2010 - IRG/WP 10-20451
A leading joint research project was financed by the ARC, engaging some of the leading Universities in Australia, to look at field techniques to determine if timber-in-service is infested with termites and decay fungi after which microwave technology will be employed to eliminate the termites and/or decay in-situ. The next step will be to quantify the damage caused on the sectional dimensions of t...
C Adam, B M Ahmed Shiday, G Brodie


Nondestructive Evaluation of Oriented Strand Board Exposed to Decay Fungi
2002 - IRG/WP 02-20243
Stress wave nondestructive evaluation (NDE) technologies are being used in our laboratory to evaluate the performance properties of engineered wood. These techniques have proven useful in the inspection of timber structures to locate internal voids and decayed or deteriorated areas in large timbers. But no information exists concerning NDE and important properties of wood composites exposed to dec...
B Illman, V W Yang, R J Ross, W J Nelson


Field test evaluation of preservatives and treatment methods for fence posts
1985 - IRG/WP 3347
This work presents the field test results after fifteen years exposure of Eucalyptus saligna fence posts treated with six different preservatives and five treatment methods. All the combinations with oil-borne preservatives presented the best results and among the waterborne preservatives, the fence posts treated by immersion method were with the lowest performance in the field test....
G A C Lopez, E S Lepage


Evaluation of two populations of Reticulitermes santonensis De Feytaud (Isoptera) by triple mark-recapture procedure
1997 - IRG/WP 97-10237
The optimisation and use of biocides is linked to the improvement in our understanding of the target organism. With this in mind we have studied 2 populations of the termite Reticulitermes santonensis De Feytaud. The first inhabiting an urban territory, the trees lining Ave. Boutroux in Paris. The colony has been estimated at 1,200,000 +/- 130,000 insects by triple mark-recapture procedure, foragi...
I Paulmier, B Vauchot, A-M Pruvost, C Lohou, M Tussac, M Jéquel, J-L Leca, J-L Clément


The evaluation of permethrin for wood preservation
1977 - IRG/WP 3107
The toxicity of the synthetic pyrethroid permethrin (NRDC 143) to a range of wood destroying insects has been investigated. In tests using Hylotrupes bajulus, Anobium punctatum, Lyctus brunneus and Reticulitermes santonensis permethrin showed a similar order of toxicity to that of gamma-BHC. Although the toxicity of permethrin to adult Anobium punctatum was of the same order as that of gamma-BHC, ...
R W Berry


An evaluation method for less termite attack execution on thermal insulation for fundation walls
2002 - IRG/WP 02-20245
According to the results by the real scale Japanese building tests, the termite installation was observed at very little spaces between foundation and insulation. The termite penetration spaces between foundation and insulation on foundation systems in Japanese wooden houses were checked by the way of streaming speed of colored water. Because of difficulty for its execution, the parts of outside a...
K Suzuki, Y Tanaka


Phoracantha semipunctata Fab. dans le sud-ouest Espagnol: Lutte et dommages
1985 - IRG/WP 1250
L G Tirado


Trend in entomology of wood in use and in storage in Nigeria
1978 - IRG/WP 180
The current and potential impact of biotic agents of wood deterioration in Nigeria is reviewed, with emphasis on the insects and marine borers, their recognition and mode of damage. Some essential areas have no doubt been neglected and these are highlighted, while future lines of approach are outlined....
M O Akanbi


Improved techniques designed for evaluation of fungicides in soil for control of dry rot fungus Serpula lacrymans
1985 - IRG/WP 2238
Improved techniques provide a laboratory method for the evaluation of chemicals in soil for control of dry rot fungus Serpula lacrymans. Results with their application to three chemicals were reported. These techniques are useful to eliminate chemicals lacking the necessary toxicity and weatherbility for dry rot control when the chemicals have been applied to the soil....
M Takahashi, K Nishimoto


Evaluation of new creosote formulations after extended exposures in fungal cellar tests and field plot tests
2000 - IRG/WP 00-30228
Although creosote, or coal tar creosote, has been the choice of preservative treatment for the railroad industry since the 1920s, exuding or "bleeding" on the surface of creosote-treated products has been one incentive for further enhancements in creosote production and utility (Crawford et al., 2000). To minimize this exuding problem, laboratories such as Koppers Industries Inc., USA, and Commonw...
D M Crawford, P K Lebow, R C De Groot


A practical method to evaluate the dimensional stability of wood and wood products
1990 - IRG/WP 2342
This paper presents a new simple method to evaluate wood and wood products for their resistance to swelling and to assess wood preservatives for their ability to dimensionally stabilize treated wood exposed to water. Permeable wood of various dimensions and treated with different preserving chemicals have been measured for swelling in the radial and tangential direction during immersion in liquid ...
J P Hösli


Japan's comments on ISO/DIS 12583-1/2
1996 - IRG/WP 96-20100
The paper describes an accelerated field test for the evaluation of timber preservative formulations against subterranean termites. The method has been adopted by the South African wood preservation industry as a screening method for the approval of wood preservatives for use under SA conditions. The method which is based upon the fungal cellar test offers a rapid means of evaluating the comparati...
P Turner, D Conradie


Protocol for evaluation and approving new wood preservative
1985 - IRG/WP 2159
M E Hedley, J A Butcher


Comparison of the agar-block and soil-block methods used for evaluation of fungitoxic value of QAC and CCA wood preservatives
1994 - IRG/WP 94-20039
The modyfied agar-block and soil-block methods were used for comparing the fungitoxic value of QAC and CCA type preservatives against Coniophora puteana and Coniophora olivacea The mass loss and moisture contents of wood were analysed....
J Wazny, L J Cookson


Termite standards questionnaire survey. Second Report
1989 - IRG/WP 1395
Information contained in replies received from IRG members responding to the survey continue to be summarised. Again, highlighted in this second report are the major termite species in the various zoogeographical regions, their damage ranking to timber-in-service, the chemicals used in control methods, and the status of the termite standards in the respondent countries....
J R J French, J P La Fage


Laboratory evaluation of chemicals as termiticides
1986 - IRG/WP 1293
Laboratory procedures are described for screening chemicals against subterranean termites. Fast-acting compounds with persistent termiticidal activity are identified in tests using a soil substrate, and slower-acting bait toxicants are evaluated in a series of tests using cellulose substrates....
S C Jones


Respiration methods used to follow the decay of wood and the toximetric evaluation of wood preservatives
1975 - IRG/WP 249
When wood is attacked and decayed by fungi, wood substance and oxygen (02) are consumed, while carbon dioxide (CO2), water and heat are liberated. Early in the 1960's workers from England, Canada and Sweden began studying CO2 evolution, with respect to decay and its control using chemical preservatives, while in Germany and the USA O2 utilization was being similarly examined. Oxygen consu...
R S Smith


The evaluation of synergistic effects of chemicals on fungicidal efficacy in crossed-paper tests
1991 - IRG/WP 2383
The mixing effects of wood preservatives were evaluated using the crossed-paper technique. Two filter paper strips (0.7 x 8 cm²) were treated by soaking with different chemicals [fungicides, a termiticide (chlorpyrifos or phoxim), a surface-active agent, a synergistic agent, and a stabilizer], and placed at right angles to each other on a fully grown mycelial mat of a test fungus in a Petri dish....
Dong-heub Lee, K Tsunoda, M Takahashi


Über Wespen als Holzverderber - Schäden, Ursachen, Bekämpfung
1978 - IRG/WP 189
Observations and a number of actual cases over recent years show that wasps have been associated more frequently with damage to wood. The nature of such damage and the agents involved are as follows: 1. Decay following infestation by Woodwasps (Siricidae). 2. Punctate marks caused by superficial gnawing and also boring into wood by larvae of the Dock sawfly (Tenthredinidae). 3. Damage due to super...
S Cymorek


Options for accelerated boron treatment: A practical review of alternatives
1985 - IRG/WP 3329
Boron wood preservatives are almost exclusively applied by momentary immersion and block diffusion storage. Alternative techniques are described which can be used to accelerate boron treatment. Diffusion coefficients have been derived to define the acceleration of diffusion with increasing temperature. Schedules are described for pressure impregnation of green timber, involving steam conditioning,...
P Vinden, T Fenton, K Nasheri


La rôle de l'expert dans l'évaluation toxicologique
1990 - IRG/WP 3589
C Boudene


Next Page