Evaluation of termiticides in field trials
1990 - IRG/WP 3633
Termiticide-treated posts and stakes have been tested at the field test site in Kagoshima, Southern Kyushu, Japan. Various commercial and alternative termiticides have been evaluated annually as TAI (termite attack index), calculated by the equation: TAI = R x P, where R is the mean of attack rating of 0 (sound), 10 (sign of tasting), 30 (slight attack), 50 (moderate attack), 100 (severe attack), ...
M Takahashi, Y Imamura, K Tsunoda, A Adachi, K Nishimoto


An evaluation method for less termite attack execution on thermal insulation for fundation walls
2002 - IRG/WP 02-20245
According to the results by the real scale Japanese building tests, the termite installation was observed at very little spaces between foundation and insulation. The termite penetration spaces between foundation and insulation on foundation systems in Japanese wooden houses were checked by the way of streaming speed of colored water. Because of difficulty for its execution, the parts of outside a...
K Suzuki, Y Tanaka


A risk model for termite attack in Australia
2003 - IRG/WP 03-10468
This paper describes a model to predict the risk of termite attack on a house in Australia. It is based on a survey of expert opinion and data from 5000 houses. The model gives a quantitative estimate of risk, and as such is useful for the development of risk management systems. An example of the application of such a system is given....
R H Leicester, C-H Wang, L J Cookson


Experimental real building evaluation of termite attack - Effect of the space between the mat foundation and the thermal insulation
2000 - IRG/WP 00-10374
For evaluating the termite resistance of the real house foundation, specially in the case of thermal insulation systems for foundation walls, thermal insulation which can be attacked by termite, must be evaluate. Because of the difficulty of the water penetration of thermal insulation, the water barrier systems can be protected against termite attacks, in our opinions. The observation on the proce...
K Suzuki, K Hagio, Y Tanaka


Flow charts for termite and decay tests to determine the natural durability of Japanese cedar (Cryptomeria japonica D. Don)
2008 - IRG/WP 08-20385
This paper deals with the experimental flow charts that were used for determination the effects of fungal decay and termite attack on Sugi heartwood during the course of the study of “Comparative studies of natural durability of Japanese cedar (Cryptomeria japonica D. Don) among the geographic cultivate”, which was carried out by Usta et al (2006)....
I Usta, S Doi


Treatment of Douglas fir heartwood with disodium octaborate tetrahydrate (Tim-BorÒ ) to prevent attack by the Formosan subterranean termite
1991 - IRG/WP 1487
Toxicity of disodium octaborate tetrahydrate (Tim-BorÒ) to Coptotermes formosanus Shiraki (Isoptera: Rhinotermitidae), and termite feeding on treated Douglas-fir heartwood were evaluated in laboratory and field tests. Feeding on filter papers impregnated with Tim-BorÒ solutions reduced but did not eliminate termite gut protozoan populations. In a forced-feeding laboratory assay, Douglas-fir hear...
M Tamashiro, R T Yamamoto, J K Grace


Detection of Acoustic Emission (AE) generated by termite attack in a wooden house
1999 - IRG/WP 99-20166
Recently, considerable attention has been paid to methods for termite control, which involves few or no chemicals. To reduce the amount of termiticide needed, it is necessary to detect termite attack in wood as early as possible. The feasibility of acoustic emission (AE) monitoring for the nondestructive detection of termite attack has been discussed previously. In this study, we propose some tech...
Y Fujii, Y Yanase, T Yoshimura, Y Imamura, S Okumura, M Kozaki


Detection of termite attack in wood using AE monitoring
1990 - IRG/WP 2355
An acoustic emission (AE) monitoring method for detecting termite activity in wood was applied to lumber of 3 by 3 cm to 10 by 10 cm square, 1 m long. Furthermore, the propagation of AEs due to the feeding activities of termites in the specimens and the locations of AE sources were analyzed. Also discussed was the feasibility of the method applied to posts out in the field of subterranean termites...
Y Fujii, M Owada, M Noguchi, Y Imamura, M Tokoro


Tanalith T - a new preservative system for protecting house frames in Australia from termite attack.
2003 - IRG/WP 03-30306
The sawn timber industry in Australia has expressed a desire for a new low cost termite treatment. The treatment needs to be on-line in the dry mill, minimising material handling costs and with a very fast processing time to meet timber flow through the dry mill. The preservative, Tanalith® T, forms an envelope on both Pinus radiata and Pinus elliotti sawn timber. Field trials conducted in Aus...
P R S Cobham, J Snow


MDF manufactured from blends of cypress pine and radiata pine shows enhanced resistance to subterranean termite attack
2001 - IRG/WP 01-40214
Medium density fibreboards consisting of blends of the naturally durable wood species white cypress pine (Callitris glaucophylla) and non-durable wood species were manufactured in a commercial plant and subjected to a bioassay using the subterranean termite species, Coptotermes lacteus. A board composed of 30% cypress pine, 30% slash pine (Pinus elliottii) and 40% of the naturally durable hardwood...
P D Evans, S Dimitriades, C Donnelly, R B Cunningham


Japanese standardized methods for testing effectiveness of chemicals against termite attack
1986 - IRG/WP 1290
Japanese standard termiticide testing methods are reviewed. There are some standard testing methods provided by Japan Termite Control Association (JTCA) and Japan Wood Preserving Association (JWPA), though most of them are common to two organizations. Methods were standardized between JTCA and JWPA in 1981, and more recently examining system was established for authorizing efficacy of wood preserv...
K Tsunoda, K Nishimoto


Detection of Termite Attack to Wood Stakes in a Monitoring Station Using Ceramic Gas Sensors and Acoustic Emission (AE) Sensor
2003 - IRG/WP 03-20271
To evaluate the termite activity in monitoring stations non-destructively, metabolic gas from termites and acoustic emission generated by feeding of termites were measured. Ten cylindrical stations with small wood stakes of Japanese red pine (Pinus densiflora) were buried around a house attacked by Coptotermes formosanus SHIRAKI. A sample air in the station was collected by sucking through a drill...
Y Yanase, Y Fujii, S Okumura, T Yoshimura, Y Imamura, T Maekawa, K Suzuki


A field method for determining the above-ground resistance of wood and wood products to attack by subterranean termite
1994 - IRG/WP 94-20035
A method for determining the above-ground resistance of wood and wood products to subterranean termites in the field is described. Termites are aggregated in 20-litre steel drums, each containing a highly susceptible timber substrate. At the centre of each drum, specimens of the test material under evaluation are sandwiched, using circular sections of wire mesh, between two layers of the substrate...
J W Creffield


Termite attack on susceptible lumber above naturally durable support posts
2000 - IRG/WP 00-10370
A multi-year field study was designed to simulate the use of naturally durable sill plates (dodai) and floor support posts in Japanese housing construction and test whether Formosan subterranean termites (Coptotermes formosanus) would tunnel over or through these resistant timbers to attack susceptible Japanese red pine (Pinus densiflora) lumber placed above them. This test was intended to explici...
J K Grace


Non-destructive stress wave measurement of decay and termite attack in experimental wood units
1986 - IRG/WP 2256
The purpose of this study was to determine if stress wave analysis could be used to monitor the degradation of wood specimens exposed to the brown-rot decay fungi (Gloeophyllum trabeum) and of wood specimens subjected to attack by subterranean termites. One hundred fifty 3/4 by 3/4 by 12 in. Southern pine specimens were used for exposure to brown-rot decay fungi and two hundred twenty-five 3/4 by ...
R F Pellerin, R C De Groot, G R Esenther


Subterranean termite attack potential in field test sites: assessment methods and field characterization
2003 - IRG/WP 03-10472
To assess subterranean termite attack potential in the field and seasonal variations, trials were set up in each of two managed silvicultural plantations, of Eucalyptus globulus and Pinus pinaster, respectively. Termite occupancy in lying dead wood was evaluated by an adaptation of the line-intersection method, and attack potential in soil was assessed by a system of stakes inserted into the groun...
T Nobre, L Nunes, L Brinca, D E Bignell


Control of termite attack using a trapping method and acoustic emission (AE) monitoring a case study at an electric power plant
1997 - IRG/WP 97-10224
To prevent subterranean termites (Coptotermes formosanus Shiraki and Reticulitermes speratus Kolbe) from invading the buildings of an electric power plant and to control their attack, artificial traps were buried around the buildings. The attack of the termites in and around the traps was monitored by detecting acoustic emissions (AE) generated by the feeding behavior of the workers. The cylindric...
Y Fujii, Y Imamura, E Iwatsubo, S Yamamoto


Effects of chemicals used for ground-line protection of hardwood poles on termite attack
1988 - IRG/WP 1356
The majority of chemicals formulatet to protect the groundline of hardwood poles in Australia have been fungicides. Nine products were tested against Coptotermes lacteus attack to determine their value in preventing attack by subterranean termites. Results indicated that Busan, high temperature creosote, pigment emulsified creosote, copper naphthenate gel and "Blue 7" had a repellent effect on Cop...
R S Johnstone, R H Eldridge


Detection of metabolic gas from termites using ceramic gas sensors
2001 - IRG/WP 01-20222
To evaluate termite attacks in wooden constructions by detecting the metabolic gas from termite colony, the basic performance of three types of ceramic gas sensors (odor-, methane- and hydrogen-selective sensors) was investigated. Four termite groups of different combinations of workers (100 to 1000) and soldiers (10 to 100) of Coptotermes formosanus Shiraki and a small specimen of Japanese red pi...
Y Yanase, Y Fujii, S Okumura, T Maekawa, K Suzuki, T Yoshimura, Y Imamura


Deltamethrin effectiveness against subterranean termite attack on wood under natural conditions
1989 - IRG/WP 1407
On fighting subterranean termites on wood, out of ground contact, the synthetic pyrethroid Deltamethrin shows positive aspects such as its efficiency and low mammalian toxicity. To evaluate its performance in conditions very similar to those in service use, specimens of Pinus sp were treated with solutions of Deltamethrin diluted in "white spirits" at 0.005% (w/w) and 0.01% (w/w) and exposed in a ...
P A Zanotto


Subterranean termites of economic importance in suburban Melbourne: Wood structures most frequently attacked and damaged
1990 - IRG/WP 1430
An examination of wood structures in forty buildings actively being attacked by subterranean termites in Melbourne revealed that all buildings were being attacked and damaged by Coptotermes species. This indicates the economic importance of these species. Hardwoods were more frequently infested than softwood species. The implications of these findings are discussed in relation to termite control, ...
J R J French


Preliminary evaluation of new quaternary ammonia compound, didecyl dimethyl ammonium tetrafluoroborate for preventing fungal decay and termite attack
2005 - IRG/WP 05-30375
This study evaluates the decay and termite resistance of wood treated with didecyl dimethyl ammonium tetrafluoroborate (DBF), a recently developed quaternary ammonia compound containing boron. DBF contains boric tetrafluoride as a counter ion in its chemical structure. Laboratory decay resistance tests were performed using brown-rot fungus, Fomitopsis palustris and white-rot fungus, Trametes versi...
S N Kartal, W J Hwang, Y Imamura


Susceptibility of heartwood of three Pinus species to attack by the subterranean termite Coptotermes acinaciformis (Froggatt)
1994 - IRG/WP 94-20026
Heartwood of plantation-grown Pinus elliottii (slash pine), Pinus caribaea (Caribbean pine) and Pinus radiata (radiata pine) was obtained from a range of locations throughout Australia and New Zealand for use in a field bioassey with subterranean termites. Timber stock was analysed for a number of stilbene and flavonoid heartwood extractive components which could contribute to variation in suscept...
M J Kennedy, L L Dixon, B C Peters


Detection of termite attack in wood using acoustic emission
1989 - IRG/WP 2331
Acoustic emission (AE) is the elastic wave produced by the strain energy released in the process of fracture of a material and propagates through it. The object of this report is to detect AEs produced by the termite activities and to evaluate the possibility of using an AE monitoring test to nondestructively detect the termite attack in wood. It was revealed that AEs were detected from the specim...
Y Fujii, M Noguchi, Y Imamura, M Tokoro


Comparative studies of natural durability of Japanese cedar (Cryptomeria japonica D. Don) among the geographic cultivates
2006 - IRG/WP 06-10592
Variation of natural durability of Japanese cedar (Cryptomeria japonica D. Don) (also known as Sugi) was investigated by accelerated tests for decay (Fomitopsis palustris (Berk. et Curt.) Murr.) and termite (Reticulitermes speratus Kolbe) attacks on 13 clones of Sugi trees from Kyushu-Okinawa Region (Fukuka, Ooita, Saga, Miyazaki, Kagoshima). For this purpose, 57 twenty-five years old Sugi trees o...
I Usta, K Takata, S Doi


Next Page