Make ready of a detection system for insect attack by acoustical method
1996 - IRG/WP 96-10183
A contract CRAFT of European research allowed to build a detector prototype able to diagnose on site the presence of Hylotrupes bajulus and termites, even during the first stages of infestation when no sign of activity is visible. Based on non destructive control technics, the device picks up the acoustical waves emitted by the insects in the wood fibers. The amplification and the filtering of the...
M Hyvernaud, F Wiest, M-M Serment, M Angulo, O Winkel


Management of the wood and additives wastes in the wood processing industries: Problematics and technical answers review
1996 - IRG/WP 96-50073
Management pathways for pure wood subproducts are well known and used; but as soon as additives like preservatives, glues, varnishes or coatings are present within the wood wastes, their disposal or valorization becomes more tricky. The different kinds of mixed wood wastes of the wood processing industries, from the sawmill to the furniture manufacture, are identified herewith and their diversity ...
S Mouras, G Labat, G Deroubaix


Granitgard used as a partial and perimeter barrier in the protection of buildings against subterranean termites
1995 - IRG/WP 95-10114
The graded granite subterranean termite physical barrier, commercially marketed as Granitgard, has a Certificate of National Accreditation issued by the Australian Building Codes Board, and is included in Australian Standards. After several years in developing the specifications and installation techniques for Granitgard, it may be used to protect almost all footing designs. Granitgard can be simp...
D M Ewart, J R J French


A rapid field bioassay technique with subterranean termites
1983 - IRG/WP 1188
Details are summarised of a field procedure which is designed to ensure continuous exposure to a replenishing termite biomass. After pre-baiting to determine the presence and identification of a termite hazard, test specimens (35 x 35 x 250 mm³) are installed vertically in the ground adjacent to and in contact with bait specimens of the same dimensions and interconnected by susceptible feeder str...
C D Howick, J W Creffield


Problems caused by termites in buildings in the State of Sao Paulo
1976 - IRG/WP 150
Termites are the main insects attacking buildings in the State of Sao Paulo - Brazil. Their attack occurs in wood and wooden materials as well as paper, textile, leather and so on....
M S Cavalcante


International collaborative laboratory comparison of two wood preservatives against subterranean termites: Third update and first report
1996 - IRG/WP 96-10174
At the 24th annual meeting of IRG in Orlando, USA, in May 1993 an international subterranean termite laboratory bioassay to compare the various preferred termite protocols used by IRG termitologists was initiated. The author was nominated to co-ordinate this comparative laboratory evaluation of two wood preservatives, copper-chrome-arsenic (CCA) and copper naphthenate (Cu-Na) against the subterran...
J R J French


Trend in entomology of wood in use and in storage in Nigeria
1978 - IRG/WP 180
The current and potential impact of biotic agents of wood deterioration in Nigeria is reviewed, with emphasis on the insects and marine borers, their recognition and mode of damage. Some essential areas have no doubt been neglected and these are highlighted, while future lines of approach are outlined....
M O Akanbi


Report and recommendations of the National Termite Workshop held in Melbourne on the 17 April 2002.
2003 - IRG/WP 03-10478
There are two parts to this Report. Part One summaries the outcomes of an industry workshop organised to better scope the subterranean termite problem, identify knowledge gaps including R&D gaps and identifying strategies including cost-effective co-ordination mechanisms for addressing the issue. Part Two is a brief review of the current state of knowledge on subterranean termites of economic ...
B M Ahmed, J R J French


Japan's comments on ISO/DIS 12583-1/2
1996 - IRG/WP 96-20100
The paper describes an accelerated field test for the evaluation of timber preservative formulations against subterranean termites. The method has been adopted by the South African wood preservation industry as a screening method for the approval of wood preservatives for use under SA conditions. The method which is based upon the fungal cellar test offers a rapid means of evaluating the comparati...
P Turner, D Conradie


Detection of feeding behaviour of termites using AE monitoring
1991 - IRG/WP 1514
Using acoustic emission (AE) monitoring, the feeding activity of the termite inhabiting a wood specimen was investigated. The amplitude and the rate of AE from the specimen of Coptotermes formosanus Shiraki was larger than that of Reticulitermes speratus Kolbe. The AE event rate was higher in the specimen with soldiers than without soldiers. The AE event rate decreased according to the resistance ...
Y Imamura, M Tokoro, M Owada, Y Fujii, M Noguchi


Physical barriers and bait toxicants: The Romeo and Juliet of future termite control
1991 - IRG/WP 1503
Soil chemical barriers are considered by some to be the most important technique for protecting buildings against subterranean termites in Australia (and elsewhere), providing a barrier against termite penetration. However, there is no such thing as a barrier that is 100 per cent +protective. And given the worldwide problems of using organochlorine termiticides, public awareness of chemical pollut...
J R J French


Report on the activities of the European Standardization Committee CEN/TC 38 'Methods of Testing wood preservatives'
1980 - IRG/WP 279 E
G Castan


In-ground performance of two formulations of chlorothalonil after five years of exposure at three test sites in Australia
1996 - IRG/WP 96-30101
Sapwood specimens of Pinus radiata D. Don and Eucalyptus regnans F. Muell. were each treated to three retentions of each of two preservative formulations (chlorothalonil in oil; chlorothalonil plus chlorpyrifos in oil) and installed in-ground at three field test sites in Australia. Specimens were treated with each formulation to achieve 3.2, 6.4 and 12.8 kg/m³ of chlorothalonil a.i. and 3.2 + 0.2...
J W Creffield, T L Woods, N Chew


Insects in dry wood (other than termites)
1977 - IRG/WP 153
S Cymorek


Effects in vivo of various tensides (surface-active agents) on Reticulitermes santonensis De Feyteaud
2001 - IRG/WP 01-10417
The results of studies of surface active agents (tensides, surfactants) on the feeding behavior and mortality of Reticulitermes santonensis De Feyteaud are described. The effects of these agents on the nature and relative populations of eight gut-inhabiting symbionts are also examined. Among the various tensides tested, bee's poison was the most effective in causing rapid termite death. A...
W Unger


Acoustic communication between Microcerotermes crassus Snyder
1982 - IRG/WP 1158
An unusual acoustic communication within a nest of Microcerotermes crassus SNYDER is reported. The signals produced by the termites are described and possible reasons for this behavior are considered....
U Kny


Termite standards questionnaire survey. Second Report
1989 - IRG/WP 1395
Information contained in replies received from IRG members responding to the survey continue to be summarised. Again, highlighted in this second report are the major termite species in the various zoogeographical regions, their damage ranking to timber-in-service, the chemicals used in control methods, and the status of the termite standards in the respondent countries....
J R J French, J P La Fage


Trials on the field control of the Formosan subterranean termite with Amdro® bait
1982 - IRG/WP 1163
Amdro® - treated paper towels were introduced into two field colonies of the Formosan subterranean termite in Hawaii. At the concentration of 180 ppm, the toxicant bait was ineffective one month after the introduction. At higher concentrations (> 6,400 ppm), the baits were eaten initially; however, one week after introduction, termites avoided or covered the baits. The 15,000 ppm baits supress...
N-Y Su, M Tamashiro, J R Yates III


Laboratory evaluation of chemicals as termiticides
1986 - IRG/WP 1293
Laboratory procedures are described for screening chemicals against subterranean termites. Fast-acting compounds with persistent termiticidal activity are identified in tests using a soil substrate, and slower-acting bait toxicants are evaluated in a series of tests using cellulose substrates....
S C Jones


Response of the Formosan Subterranean Termite (Coptotermes formosanus) to Cellulose Insulation Treated with Boric Acid in Choice and No-Choice Tests.
2004 - IRG/WP 04-10532
The tunneling ability of the Formosan subterranean termite Coptotermes formosanus Shiraki through a cellulose insulation material containing11.1% boric acid was tested in choice and no-choice bioassays. We examined tunneling behavior and mortality of termites exposed to treated and untreated insulation material in miniature simulated wall voids. In a choice test termites tunneled through untreat...
M E Mankowski, J K Grace


Reticulitermes lucifugus Rossi, and its damages in Turkey
1982 - IRG/WP 1152
The moist-wood termite, Reticulitermes lucifugus Rossi, is generally observed on the wood material which has a direct contact with the soil as trunks and fence stakes. It was reported to be found in some provinces in Turkey. The termite has been seen in these areas so far at the endemic level, but any considerable damage or epidemy has not yet been reported. Considerable damages were observed on t...
O A Sekendiz


Termite and decay protection - A superficial barrier field test
1983 - IRG/WP 3257
Samples of Pinus radiata were given a superficial barrier treatment and installed in the ground at two sites for five years to observe termite and fungal attack. The three best treatments of the series were Denso petroleum tape, Koppers hot dip tar enamel, and Arquad 2C/75 alkyl ammonium compound. As new fungicides and insecticides become available they are being added to the test using the same s...
R S Johnstone, W D Gardner


Feeding preference behaviour of Crytopermes cynocephalus Light and Coptotermes curvignathus Holmgren on twenty-eight tropical timbers
1985 - IRG/WP 1251
A study on the feeding preference behaviour of a dry-wood termite Cryptotermes cynocephalus Light and a subterranean termite Coptotermes curvignathus Holmgren on 28 species of tropical timbers has been conducted. The weight-loss of individual timber and the mortality of termite was·recorded after 5, 10, 15, 20 and 25 days of exposure. The results reveal that there are only five species among 28 s...
Nana Supriana


A method for screening termite baits using Coptotermes lacteus mounds
1984 - IRG/WP 1237
A method with several variations designed to rapidly screen potential bait substrates using Coptotermes lacteus mounds is described. The equipment used in this method is relatively inexpensive, readily prepared in the laboratory, and easily installed into active mounds in the field. Bait substrates are in continuous contact with a 'high termite hazard', and may be monitored with ...
J R J French, P J Robinson


Boron treatments for the preservation of wood - A review of efficacy data for fungi and termites
1994 - IRG/WP 94-30037
Boron treatments have been used for many decades for protection of timber from biological attack and also as a fire retardant treatment. In recent years there has been an increased interest in boron treatments as an option for protection of structural timbers' e.g. timber framing used in termite risk areas. This paper reviews efficacy data for both fungi and termites relevant to this end-...
J A Drysdale