Creosoted radiata pine by non-pressure methods
1988 - IRG/WP 3486
Posts of Pinus radiata have been impregnated with creosote by immersion for 1, 3, and 7 days, and by hot-and-cold open tank with hot bath temperatures at 40°C and 60°C. On the basis of the retention rates obtained, suitable procedures are described for wood elements that are going to be in ground contact, and an analysis is made of the way in which the variables tested affect the results....
M V Baonza Merino, C De Arana Moncada


European standardization for wood preservation
1989 - IRG/WP 2335
G Castan


Some aspects of laboratory and field testing methods of antitermite wood preservatives
1973 - IRG/WP 235
Various methods for laboratory testing of antitermite activity of wood preservatives are described. The results of simultaneous tests of three water-borne preservatives, according to the various methods are discussed, and comparison is made with results of field tests on the same three preservatives, showing a fairly good accordance between laboratory results and field results....
M Fougerousse


A method for screening termite baits using Coptotermes lacteus mounds
1984 - IRG/WP 1237
A method with several variations designed to rapidly screen potential bait substrates using Coptotermes lacteus mounds is described. The equipment used in this method is relatively inexpensive, readily prepared in the laboratory, and easily installed into active mounds in the field. Bait substrates are in continuous contact with a 'high termite hazard', and may be monitored with ...
J R J French, P J Robinson


Electron microscopic detection and chemical analysis of three-lamellar structures in wood-destroying fungi
1984 - IRG/WP 1240
In the course of transmission electron microscopical investigations of pine wood decay by various brown- and white-rot fungi extracellular three-lamellar structures (TLS) formed by the fungi were found in specimens stained with ruthenium red. These structures occured in the lumen of the wood cell surrounding the hypha at the outermost layer of the fungal cell wall. In the course of the investigati...
R Foisner, K Messner, H Stachelberger, M Röhr


Utility, deterioration and preservation of marine timbers in India
2005 - IRG/WP 05-40314
Timber is extensively used in India in the marine environment for various purposes due to its several advantages over modern materials. Infact, its use is increasing in recent years, finding wider and wider applications and this scenario is not going to change in the near future. Though, the bio-deterioration problem is found very severe in tropical waters, still indigenous methods are widely empl...
B Tarakanadha, M V Rao, M Balaji, P K Aggarwal, K S Rao


What can DNA fingerprinting, aggression tests and morphometry contribute to the identification of colonies of the Formosan subterranean termite
2000 - IRG/WP 00-10371
Multilocus DNA fingerprinting, aggression tests and morphometry were compared to evaluate their potential for the identification of colonies of the Formosan subterranean termite, Coptotermes formosanus (Isoptera: Rhinotermitidae) in Hawaii. DNA fingerprinting separates the termites from all studied collection sites. Since the genetic similarity between termites from different collection sites lies...
C Husseneder, J K Grace


Detection of defects in standing poles by X-ray techniques
1980 - IRG/WP 2132
The application of X-ray techniques to wood pole inspection procedures has been evaluated. Internal defects were accurately identified using X-ray inspection methods. These methods and their possible influence on the safety and economic aspects of wood pale utilization are discussed....
W D Gardner, R S Johnstone, W Pitt


Working Group II: Sub-group: Methods of testing anti-stain chemicals for protecting sawn lumber during storage, transit
1978 - IRG/WP 2121
R Smith


Non-destructive testing for the detection of defects in poles (letter to members of Sub-group 5 of WG II)
1982 - IRG/WP 2171
IRG Secretariat


European standardization for wood preservation
1990 - IRG/WP 2359
G Castan


Report on a field demonstration of methods for detecting defects in wood poles
1984 - IRG/WP 2232
P I Morris, H Friis-Hansen


Experimental test site to prevent maritime pine logs from bluestaining: water-spraying and water-immersion methods
2003 - IRG/WP 03-10497
Following a storm which led to windfall wood, a research project was launched to develop preservation methods with a low environmental impact for maritime pine logs. These preservation methods are intended to be suitable for large-scale storage areas of maritime pine. In addition the aim was to maintain wood quality during long term storage. An experimental field test with 1 900 m3 of maritime pin...
I Le Bayon, H Callot, D Reuling, C Brunet, P Castéra


Detection of semi-quantitative and qualitative enzymatic activities of blue-stain fungi
2000 - IRG/WP 00-10347
Blue-stain, produced in forests, continues to be a problem in countries of moderate climate. In forestry, in certain geographical areas of Spain, it has been observed that anti-sapstain products have not always been efficient, as their fungicidal effectiveness varies on occasion, depending on the species of wood and microbiota that exist in the region. It is not always easy to identify the species...
M T De Troya, F Llinares, D Muñoz-Mingarro, M J Pozuelo, N Acero, C Rodríguez-Borrajo, A M Navarrete


An appraisal of methods for environmental testing of leachates from salt-treated wood (2)
1998 - IRG/WP 98-50110
For wood preservatives for use in hazard class 4 information on the ecotoxicity of preservatives and ingredients as well as on the effect of losses from impregnated timber is needed for a proper environmental risk assessment. In the evaluation of a suitable test procedure the leaching behaviour of copper-based formulations was studied using analytical and ecotoxicological test methodology. These ...
H W Wegen, A Platen, G M F Van Eetvelde, M Stevens


Detection of brown rot decay in wood by ion mobility spectrometry
1991 - IRG/WP 2377
A test method for the detection of brown rot decay in wood is described and involves a two-step procedure: thermal release of vapours from wood samples followed by analysis using Ion Mobility Spectrometry (IMS), with results being obtained in 5-10 seconds. The advantages, limitations as well as the detection limit of the technique are presented....
A H Lawrence, T Nilsson


Wood preservation in East European countries
1989 - IRG/WP 3527
The paper discusses the main problems of wood preservation in Bulgaria, Czechoslovakia, German DR, Hungary, Poland, Rumania and the USSR. The main types of wood preservatives produced have been presented, as well as the state of standarization to test their properties. There have been considered methods of wood treatment in use and application range of treated wood....
J Wazny


Detection of incipient brown rot decay in wood by fourier transform infrared spectrometry
1987 - IRG/WP 2275
Fourier transform infrared spectrometry was evaluated as a possible method for detecting different levels of brown-rot decay in pine sapwood. By using first derivative spectra and regression analysis, an equation based on 4 absorption peaks, normalized with an internal standard peak, was developed. The correlation between weight loss and absorption was highly significant indicating that this is a ...
D D Nicholas, T Schultz


A comparison between methods for evaluating the water repellency of wood
1989 - IRG/WP 2328
Wood specimens treated with a number of water repellent formulations have been tested for their water repellency according to four laboratory test methods, based on weight increase, swelling and contact angle measurements, in order to assess the degree of agreement between the different methods. Treatments representing formulations with a wide range of water repellent efficiency were tested both i...
R Nussbaum


Collaborative tests on the influence of solvent and drying method on the toxic limit of wood preservatives against Basidiomycetes
1974 - IRG/WP 248
Seven institutes from five countries, Austria, England, France, Germany and the Netherlands have collaborated in a study on the influences of solvent and drying method on the toxic limits of wood preservatives against Basidiomycetes tested according to the agar-block method. Two preservatives, a 25% pentachlorophenol-concentrate and tributyltinoxide were applied to pine sapwood and beech and teste...
T Hof


Fungal degradation of wood treated with metal-based preservatives. Part 2: Redox states of chromium
1996 - IRG/WP 96-10164
Concerns have arisen about the leaching of heavy metals from wood treated with metal-based preservatives, such as chromated copper arsenate (CCA). Of particular concern is the toxic redox state of chromium and arsenic in aging and decayed CCA-treated wood. Generally, hexavalent chromium is more toxic than trivalent chromium and trivalent arsenic is more toxic than pentavalent arsenic. The desired ...
B Illman, S Bajt, T L Highley


CCA fixation experiments. Part 2
1989 - IRG/WP 3505
CCA fixation in wood was measured by both squeezing solution from treated wood that had not been dried and analyzing the solution for copper, chromium and arsenic, as well as using a chromotropic acid test to detect the presence of chromium VI. Both methods provide useful information on the CCA fixation process and illustrate that chromium VI disappears as CCA becomes fixed within wood....
W S McNamara


Termite standards questionnaire survey - First Report
1988 - IRG/WP 1354
Information contained in replies received from IRG members responding to the termite standards questionnaire survey are summarised. Highlighted in the results of this first report are the major termite species in the various zoogeographical regions, their damage ranking to timber-in-service, the chemicals used in control methods, and the status of termite standards in the respondent countries....
J R J French, J P La Fage


Spot-tests for TnBTO and AAC preservatives
1984 - IRG/WP 3279
Nineteen indicator systems were examined as potential alternative spot-tests for preservative penetration in TnBTO- (bis-tributyltin oxide) or AAC- (alkyl ammonium compound) treated wood. Results indicated phenylfluorone as an acceptable alternative to pyrocatechol violet for assessment of TnBTO, and cobaltous thiocyanate or a bromocresol green/quinine sulphate mixture as alternatives to bromophen...
D V Plackett


The Pilodyn instrument as a non-destructive tester of the shock resistance of wood
1978 - IRG/WP 2107
A new non-destructive shock resistance tester, the PILODYN, has been developed. The instrument measures the fracture surface area created by a constant amount of energy. It operates by shooting a blunt pin into wood by an exact amount of energy. The penetration depth is read on a scale. A wide field of application is open to a non-destructive shock resistance tester such as: 1) assessment of the r...
P Hoffmeyer