IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 51 documents. Displaying 25 entries per page.


Electricity pole treatments - Wedding Bells State Forest. Inspection September 1983
1985 - IRG/WP 3334
A survey to study the extent of soft rot in hardwood poles in N.S.W. was commenced in 1975. The results of the survey, published in 1982, indicated that a number of factors contributed towards soft rot attack on poles in service. A detailed rest on pole treatments and maintenance procedures was established in 1976, at a site in Wedding Bells State Forest near Coffs Harbour. The site selected was k...
R S Johnstone, R H Eldridge


Resistance of two commercial cement-bonded rubberwood particle composites to decay and termites
2000 - IRG/WP 00-10338
Two types of cement-bonded rubberwood (Hevea brasiliensis) particle composites (tradenames: Cemboard and Primaflex in Malaysia), were evaluated for termite resistance (prevalent termite: Coptotermes curvignathus) in the field, and decay resistance (test white rot fungi: Schizophyllum commune and Pycnoporus sanguineus; test brown rot fungus: Gloeophyllum trabeum; test soft rot fungi: Phialophora fa...
A A H Wong


Glass splinters as physical termite barriers: Optimized material properties in use with and without insecticidal pretreatment minimizes environmental contaminations
1991 - IRG/WP 1476
The major advantage of physically acting barriers against termites using sand or cinder is to be impenetrable for a number of termite species by showing environmental compatibility in a high degree. The major disadvantage of these barriers is the ability of termites to build galleries over them. Glass or glass-like materials are showing optimum material properties: crushed to a particle size from ...
M Pallaske, A Igarashi


Subterranean termite foraging behaviour and the development of baiting methods used for termite control by the Division of Forest Products
1994 - IRG/WP 94-10058
Given the premise that alternatives to current subterranean termite control measures using organochlorine insecticides and arsenic trioxide have been actively researched by our Division for over ten years, emphasis on baiting methods in controlling these termites has been a major facet of our research. Recently, the new Australian Standard (AS 3660 -1993) was released which outlined the use of phy...
J R J French, J W Creffield, B M Ahmed


List of fungi observed in avalanche barriers located in subalpine and alpine regions
1970 - IRG/WP 17
In the Subalpine region (Schilt-Stein; 1400-1500 m above sea level) the following fungi were observed: Basidiomycetes: Corticium alutaceum, Corticium ochraceum, Corticium sp., Collybia sp., Dacryomyces deliquescens, Exidia glandulosa, Lenzites abietina, Lenzites sepiaria, Lenzites trabea, Osmoporus odoratus, Peniophora pubera, Peniophora sp., Polystictus abietina, Poria placenta, Poria mucida, Po...
O Wälchli


Termite physical barriers: Current status of retrofitting Granitgard around 'mock-up' buildings
1994 - IRG/WP 94-10057
Two years ago a field experiment was designed and installed to evaluate the effectiveness of Granitgard, the commercial name of a grade of crushed granite rock, as a termite physical barrier when retrofitted around 'mock-up' buildings. The field station is located at Walpeup in the semi-arid mallee region of northern Victoria (360 km north of Melbourne), and there are several ind...
J R J French, B M Ahmed


Surface Barriers for Protection of Culture and Heritage Wooden Objects from Insect Attack
2004 - IRG/WP 04-40286
Anoxic treatment is an environment friendly procedure for eradication of wood boring insects in wooden objects of cultural and historical heritage. However, after the anoxic treatment, wooden antiques remain susceptible to further insect attacks. Possible protection against insects could be provided by the so-called post-repression protective barriers. Potential coating materials for such barriers...
M Petric, M Pavlic, B Kricej, M Humar, F Pohleven


Termite physical barriers: update on retrofitting Granitgard™ around 'mock-up' buildings after five years
1997 - IRG/WP 97-10226
This field experiment was installed five years ago (March 1992) to evaluate the effectiveness of graded crushed granite stone, commercially marketed under the name Granitgard™, as a physical barrier when retrofitted around 'mock-up' buildings. The field site is located at Walpeup in the semi-arid mallee region of north-west Victoria (360 km from Melbourne), and there are eight ...
J R J French, B M Ahmed


Prevention of sapstain in logs using water barriers
1997 - IRG/WP 97-30147
Placing logs in ponds or under water sprinklers to keep moisture levels high enough to prevent oxygen tensions rising above inhibitory levels, is a proven method of preventing sapstain. The objective of this experiment was to determine if water barriers significantly reduce the rate of sapstain penetration into logs by maintaining moisture contents, and consequently oxygen tensions, at inhibitory ...
R N Wakeling, D R Eden, C M Chittenden, B Carpenter, I Dorset, J Wakeman, R Kuluz


The resistance of wood coated with different water-borne paints against colonisation by decay fungi
1996 - IRG/WP 96-10165
The susceptibility of wood painted with model paints of known composition to decay fungi was tested without previous weathering. Included in the study were five alkyd emulsion paints and five acrylic paints; one linseed oil paint and two solvent-borne alkyd paints. It was found that several components influenced the susceptibility of these paints. The results of the present study indicate that the...
J Bjurman


Efficacies of physical barriers for preventing blue-stain of Japanese red pine logs
2007 - IRG/WP 07-20359
This paper deals with field trials on physical barriers to prevent blue stain on Japanese red pine logs using a fly screen, bark and leaves of Japanese cedar as covering materials. These barriers arrested blue stain and bark beetle attacks to low levels than control for 1 month except covering with a small amount of bark. Covering with the fly screen and a large amount of bark permissibly suppress...
H Taniuchi, T Koiwa, H Masuya, S Doi


A method and apparatus for rapid assessment of termite barriers.
2007 - IRG/WP 07-20366
This paper describes an apparatus for rapid assessment of barriers to subterranean termite foraging. The method and apparatus arose from the development of a novel physical termite barrier. The barrier had to be flexible, resilient, able to be applied as a liquid and be neither toxic nor repellent. This posed a special problem as existing laboratory assessment techniques did not offer a sufficient...
D McG Ewart


Expected service life of outdoor wooden structures such as guard fences and noise barriers indicated by questionnaire survey
2007 - IRG/WP 07-20372
Forestry Agency, Japan has intended to expand the utilization of domestic wood in many areas such as not only housing constructions also outdoor structures. In order to respond the policy, actual durability and service life of these structures should be clarified, and the guide line for archiving planned service life also should be established. Japan Wood Preservers Industries Association carried ...
K Yamamoto, A Makita, A Yamaguchi, T Shiraishi, K Maeda, D Tezuka, S Katsumata, M Higaki


Effect of barriers on moisture content of treated and non-treated utility poles
2007 - IRG/WP 07-40369
The potential for non-biocidal barriers to slow moisture sorption was investigated using butt treated western redcedar poles immersed in either water or moist soil over a 2 year period. Moisture sorption was initially slowed by the barriers, but openings at the bottoms of the barriers eventually allowed moisture to migrate upward. Moisture levels in wrapped poles eventually reached those found in...
C S Love, J J Morrell


Field Liners as physical barriers to prevent wooden utility pole decay in soil: An accelerated field simulation trial
2008 - IRG/WP 08-20384
Field Liners (FL’s), plastic sleeves used to protect in-ground wooden poles from fungal and termite damage, have been tested before as physical barriers to prevent contact between soil and wood and to retain wood preservative treatment. These earlier studies concentrated mostly on creosote preserved poles and early generation FL’s which were cumbersome in their application. The newer generatio...
A R Howgrave-Graham, L J Cookson, T Hale


Use of biological and low toxicity products against subterranean termites
2009 - IRG/WP 09-20410
The climatology of Mediterranean countries is favourable to the development of termites that cause important damage to wood structures in both furniture and buildings. Until a few years ago the treatment for this type of insect was based on the impregnation of the wood with chemical products. The use of these chemicals is now being restricted in Europe since the publication and harmonization of n...
M T Troya, M J Prieto, F Rubio


Comparison of Micronized Copper Particle Sizes
2010 - IRG/WP 10-30538
The particle sizes of micronized copper formulations derived from treating liquids were compared with those deposited in wood treated with those liquids. The intent was to determine if agglomeration occurs in the liquids during the treatment process, if screening of the agglomerates occurs in the wood and if there are any apparent differences in the particle sizes in the wood. Three formulations...
C R McIntyre


The resistance to Basidiomycetes fungi of chipboard 35 years after their industrial preservation with wood preservative on fluoroborate basis
2011 - IRG/WP 11-40546
The research on wood-based panels’ (WBP) behaviour towards fungi impact demonstrated rather low resistance of wood-based materials to wood rotting fungi. However, these materials are used in construction under conditions favourable to fungi growth. In such conditions WBP treated with wood preservatives should be used. Preservation durability is of great importance in such cases. The resistance o...
A Fojutowski, A Kropacz


Biological performance of wood- and bamboo-polypropylene composites: Effects of particle content, particle size and Zn borate
2012 - IRG/WP 12-40577
Particle content and size of wood material in wood plastic composites (WPCs) can affect efficacy of WPCs against fungi and termites. This study evaluated fungal and termite resistance of WPCs manufactured by using two different levels of particle content (50 and 70%) and three different particle sizes (30, 60, and 100 mesh). In fungal resistance tests, Tyromyces palustris, a standardized test fung...
S N Kartal, S Aysal, E Terzi, T Yoshimura, K Tsunoda


Practical extraction of metals from CCA-treated wood
2014 - IRG/WP 14-50305
The extraction effects of acid concentration, reaction time and temperature in a microwave reactor on recovery of chromated copper arsenate (CCA)-treated wood were evaluated. Extraction of copper, chromium, and arsenic metals from CCA-treated southern pine wood samples with three different wood particle sizes (i.e., (1) 0.5 cm3, (2) 0.5x05x1.0 cm, and (3) 0.5x0.5x1.5 cm) was investigated using a m...
Bin Yu, Chung Y Hse, T F Shupe


Accelerated Weathering Performance of Impregnated Wood Samples Coated with Zinc by Means of Plasma-Assisted Particle Deposition
2016 - IRG/WP 16-30682
Many different methods are currently applied for wood protection against outdoor conditions. The most important of these is the process of impregnation with liquid substances. However, this kind of wood preservatives cannot provide a long-term protection of wooden surfaces. Weathering-resistant surfaces can be obtained by applying UV absorbing agents. In this study, the influence of zinc particles...
A Can, H Sivrikaya


A Comparison on Penetration of Silica Sol in Scots pine and Southern pine wood
2016 - IRG/WP 16-40722
Penetration is one of the most important issues to be considered in wood impregnation with various kinds of chemicals in liquid form. Scots pine (Pinus sylvestris) and Southern pine (Pinus spp.) are two frequently used wood species for treatment, such as preservative treatment. With the development of treating systems, some micro- or nano-sized aqueous modifiers are emerging in the market, which p...
Mingyang Sun, Jinzhen Cao


Effect of Particle Size on Wax Distribution in Paraffin Wax Emulsion Impregnated Wood
2017 - IRG/WP 17-40779
Paraffin wax emulsion impregnation has been a common eco-friendly approach for improving water repellency of wood. In this study, southern pine (Pinus spp.) and Scots pine (Pinus sylvesteris L.) samples were impregnated with paraffin wax emulsions of different solid contents and particle sizes, and then the time domain nuclear magnetic resonance (TD-NMR) was used to elucidate the influence of part...
Wang Wang, Jinzhen Cao, Yiheng Huang


Preventivephysical barriers against subterranean termites species for building protection: How to implement innovative materials to reach efficacy requirements
2018 - IRG/WP 18-40845
As the European regulation dealing with the use of biocides (BPR) for preventive protection of buildings against subterranean termites is leading to more and more pressure on physico-chemical barriers currently used (PT18), some existing developments are focusing attention on physical biocides-free barriers. The main target is then to avoid the use of active ingredients, to stay out of the BPR sco...
N Delourme-Fonseca, P Poveda, F Simon


Physical barriers against marine borers based on synthetic polymers
2020 - IRG/WP 20-30754
Currently in Spain there are no chemical treatments that are really effective against attacks of marine bores in civil constructions within more or less permanent contact with seawater. On the other hand there are also no physical barriers that allow easy placement or execution, and much less offer a minimum guarantee of performance in the medium or long term. In fact, in these recent years there ...
A Lozano, D Lorenzo, M Alonso, J J del Coz, F Álvarez


Previous Page | Next Page