IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 105 documents. Displaying 25 entries per page.


Decay factors in termite in-ground monitoring stations
2012 - IRG/WP 12-10775
Subterranean termites are serious pests of wood in service in much of the world. One of the most common techniques for monitoring and controlling termites is the use of in-ground monitoring stations which comprise a wood or other cellulosic material monitor (cellulosic matrix) and/or a termiticide bait held in a open plastic holder so facilitates examination and the termite access. Wood and other ...
S Duarte, A M Taylor, Jae-Woo Kim, J D Lloyd, M Duarte, L Nunes


The first two years of an area wide management program for the Formosan subterranean termite in the French Quarter, New Orleans, Louisiana
2000 - IRG/WP 00-10357
The Formosan subterranean termite, Coptotermes formosanus, is a serious pest in several parts of the world and is the most destructive insect in Louisiana. The density of the Formosan subterranean termite in the French Quarter, New Orleans, Louisiana, USA is very high. A large area pilot test for area wide management of this insect was begun in 1998 in the French Quarter to reduce densities of ter...
D R Ring, A L Morgan, W D Woodson, A R Lax, X P Hu, E D Freytag, L Mao


Preventing decay in termite monitoring stations
2010 - IRG/WP 10-30546
In-ground monitoring stations and termite baits are widely used in the southern United States with the intent of detecting and eradicating subterranean termite activity near buildings. These stations comprise a wood (or other cellulose material) substrate (monitor) and perhaps a termiticidal toxicant (bait) held in a plastic cage that allows for both easy examination and access by termites. The us...
A M Taylor, Jae-Woo Kim, S Duarte, L Nunes, J D Lloyd


Non-destructive monitoring of structure and moisture dynamics of plywood exposed outdoors to improve service life prediction and fit-for-purpose design
2015 - IRG/WP 15-20570
Plywood is an important construction material yet prone to water uptake, which can decrease strength and increase decay risk. To predict service life and improve fit-for-purpose design, it is crucial to understand the moisture behavior and structural changes of plywood. In this research, several plywood specimens were exposed outdoors for approximately one year. During this period, the moisture di...
W Li, J Van den Bulcke, I De Windt, M Dierick, J Van Acker


Review on protection of timber bridges in Norway and other countries
2017 - IRG/WP 17-40809
Wood plays a major role in design and construction of modern bridges in Norway. Typical elements of those bridges are double impregnated glued laminated members, stress laminated timber decks, slotted-in steel plates, metal cladding of the surfaces of loadbearing members, and cross girders made of steel. Selected examples of timber bridges in Norway are presented. This review paper gives an overvi...
K-C Mahnert, U Hundhausen


Moisture performance of wooden shingles tested on the Golobar cable yarding
2023 - IRG/WP 23-20704
Wood is a traditional roofing material in Europe and other parts of the world. In the 17th century, wooden roofing was generally used on more important buildings, but today it is mainly used on huts and houses in the Alpine regions. As wooden roofing is expensive, we investigated the possibility of extending the service life of the roofing through material selection and details. The roof of the Go...
M Humar, B Lesar, D Kržišnik


Improvements of monitoring the effects of soil organisms on wood in fungal cellar tests
1996 - IRG/WP 96-20093
Accelerated testing the durability of preservative treated timber in a so called "fungal cellar" or "soil-bed" to evaluate its performance in ground contact is widespread practice. In order to obtain a more accurate and reproducible estimate of preservative performance, several institutes, among them the BAM in Berlin, have routinely carried out static bending tests in addition to visual examinati...
I Stephan, S Göller, D Rudolph


An evaluation method for less termite attack execution on thermal insulation for fundation walls
2002 - IRG/WP 02-20245
According to the results by the real scale Japanese building tests, the termite installation was observed at very little spaces between foundation and insulation. The termite penetration spaces between foundation and insulation on foundation systems in Japanese wooden houses were checked by the way of streaming speed of colored water. Because of difficulty for its execution, the parts of outside a...
K Suzuki, Y Tanaka


Detection of feeding behaviour of termites using AE monitoring
1991 - IRG/WP 1514
Using acoustic emission (AE) monitoring, the feeding activity of the termite inhabiting a wood specimen was investigated. The amplitude and the rate of AE from the specimen of Coptotermes formosanus Shiraki was larger than that of Reticulitermes speratus Kolbe. The AE event rate was higher in the specimen with soldiers than without soldiers. The AE event rate decreased according to the resistance ...
Y Imamura, M Tokoro, M Owada, Y Fujii, M Noguchi


Quantitative determination of Chromium: A comparison of three instruments
1995 - IRG/WP 95-50053
A comparison is made between three instruments for measuring levels of chromium in the leachate of copper-chrome-arsenic (CCA) treated timber. These include an atomic absorption spectrophotometer, an inductively coupled plasma spectrometer and the RQflexâ. The RQflexâ is a new hand-held instrument which measures chromium by dipping a ReflectoquantÒ strip into the leachate and inserting the stri...
S Walley, P R S Cobham, P Vinden


Exposure monitoring of creosote vapors
1989 - IRG/WP 3511
Creosote oils contain hundreds of compounds. During impregnation and handling of treated wood the main component in the vapors released in air is naphthalene. Other main components are alkyl naphthalenes, indene, phenol and its methyl derivatives, benzothiophene, diphenyl, acenaphthalene and fluorene. In the measurement of creosote vapors, naphthalene can be used as an indicator agent. One of the ...
P Heikkilä, M Loutamo, V Riihimäki, M Romo


A simple leaching procedure for in-plant monitoring of CCA fixation
1993 - IRG/WP 93-30023
A simple leaching test is described to quantitatively estimate the extent of fixation of chromated copper arsenate (CCA) preservative treated wood products. It is based on the reaction between diphenylcarbazide and unreacted hexavalent chromium leached from borings taken from treated wood during the fixation process. The test requires about 20 minutes to complete and can be set up in a treating pl...
P A Cooper, Y T Ung


Forest products laboratory methodology for monitoring decay in wood exposed above ground
1995 - IRG/WP 95-20074
Research at the Forest Products Laboratory on the durability of wood in service has included a full complement of laboratory and field tests. In this report, we present a review of past and current methods used to evaluate the condition of preservative-treated wood exposed above ground. Current protocols are described for tests on wood packaging, roofing, and dimension lumber....
R C De Groot, T L Highley


Experimental real building evaluation of termite attack - Effect of the space between the mat foundation and the thermal insulation
2000 - IRG/WP 00-10374
For evaluating the termite resistance of the real house foundation, specially in the case of thermal insulation systems for foundation walls, thermal insulation which can be attacked by termite, must be evaluate. Because of the difficulty of the water penetration of thermal insulation, the water barrier systems can be protected against termite attacks, in our opinions. The observation on the proce...
K Suzuki, K Hagio, Y Tanaka


Wood preservatives ecotoxicology on Gammarus pulex (L.) - toward an environmental monitoring method and a getting rid of pollution process
2005 - IRG/WP 05-50224-9
Wood preservatives can have a strong impact on freshwater invertebrates when used close to aquatic ecosystems. It has been reported in Jura that different arthropod taxa, specially crustaceans, have disappeared along several kilometers downstream from factories using insecticides and fungicides as wood preservatives. The crustacean Gammarus pulex (L.) is a relevant bioindicator to characterize th...
O Adam, F Degiorgi, G Crini, P-M Badot


Technique for monitoring absorption during a vacuum pressure process
1992 - IRG/WP 92-3696
A laboratory technique was developed and an apparatus constructed which allowed for the direct and continuous measurement and observation of volumetric uptake of water-borne preservative into wood samples throughout a controlled vacuum-pressure treatment process. Fractional filling of void space was calculated. Graphing (fractional saturation) against time allows prediction of optimum cycle length...
A J Pendlebury, J A Petty


Preservatives treatment and field test monitoring of spruce pole stock: CCA and fumigant treatments
1990 - IRG/WP 3619
The fumigants trichloronitromethane (chloropicrin) and sodium N-methyldithiocarbamate (SNMDC) were used to treat red spruce pole stock, either CCA treated or untreated, through holes bored through the pole's center. The poles were analyzed for the presence of microorganisms immediately before ground installation and again after installation at a pole test site. Monitoring of fumigant move...
A J Pendlebury, B Goodell


The influence of building design on wood decay
2000 - IRG/WP 00-10339
The cheapest and most effective way to prevent wood decay is to KEEP THE WOOD DRY! You and I know that, but we often forget and attempt a preservative solution to a problem better solved with good design and construction. It's also the answer to a frequently missed exam question in my Architecture class. Just as caulking is a poor substitute for proper design, so preservative treatment sh...
W W Wilcox


A deflection test for monitoring decay in miniature beams
1986 - IRG/WP 2269
A laboratory apparatus for assessing decay in small stakes is described. It involves the measurement of deflection in a static bending apparatus using a displacement transducer linked to a microcomputer. Measurements are non-destructive, rapid, accurate and automatic and decay can be assessed repeatedly over long time periods....
S M Gray


Field trials on preserved timber out of ground contact
1978 - IRG/WP 3154
This report describes two different field trials studying the performance of preservative treatments on timber exposed to the weather, but above the ground. Results are presented on the protection afforded against decay, and on the efficiency of water-repellent preservative treatments in controlling the uptake of moisture by the timber. Proposals for a standard field test system are briefly discus...
D F Purslow, N A Williams


Feasibility of termite control using crushed cement-stabilized sludge (Polynite) as a physical barrier and acoustic emission (AE) monitoring
2000 - IRG/WP 00-10381
In Japan, the damages by the subterranean termites (Coptotermes formosanus Shiraki and Reticulitermes speratus Kolbe) are more common. Recently, the more attention is paid to the methods of the termite controls of less- or non-chemical. As one of the non- chemical treatment, physical barrier using particles as basalts 1) , granites, and gravels 2) were investigated in terms of its safety, cost eff...
Y Yanase, M Shibata, Y Fujii, S Okumura, K Iwamoto, T Nogiwa, T Yoshimura, Y Imamura


Feasibility of AE (Acoustic Emission) monitoring for the detection of the activities of wood-destroying insects
1992 - IRG/WP 92-2416
The feasibility of acoustic emission (AE) as a nondestructive testing method for the detection of the wood destroying insects was investigated. AEs were detected from the wood specimens under feeding attack of sugi bark borers or powder-post beetles. However, the feasible monitoring area of an AE sensor is influenced by the attenuation of AE amplitude, so that this could be a problem in the practi...
Y Fujii, Y Imamura, E Shibata, M Noguchi


Generic code of good practices for wood protection facilities. Part 1: Wood protection (antisapstain) facilities
1993 - IRG/WP 93-50003
In general, the potential of high toxicity (aquatic and human) of wood protection (antisapstain) chemicals dictates the need to protect the environment and humans from its harmful effects. This document is a compendium of recommendations for the design and operating practices of wood protection facilities. The suggested recommendations focus on achieving the objectives of protecting the environmen...
G Das, V N P Mathur


Detection of Acoustic Emission (AE) generated by termite attack in a wooden house
1999 - IRG/WP 99-20166
Recently, considerable attention has been paid to methods for termite control, which involves few or no chemicals. To reduce the amount of termiticide needed, it is necessary to detect termite attack in wood as early as possible. The feasibility of acoustic emission (AE) monitoring for the nondestructive detection of termite attack has been discussed previously. In this study, we propose some tech...
Y Fujii, Y Yanase, T Yoshimura, Y Imamura, S Okumura, M Kozaki


Results of survey conducted at Orlando to solicit attendee feedback on program design
1994 - IRG/WP 94-60026
J N R Ruddick


Next Page