IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 147 documents. Displaying 25 entries per page.


Comparison of variable, constant and fluctuating pressure methods
2001 - IRG/WP 01-40212
The objective of this work was to evaluate potential improvements in pressure treatment arising from the use of a control valve. A constant pressure of 1035 kPa was compared to the conventional variable pressure method where the pressure is allowed to drop to 860 kPa as the solution is absorbed by the wood. A fluctuating pressure method (FPM) where the pressure cycles between 1000 and 1070 kPa was...
S M McFarling, P I Morris


Comparison of the FRIM and forest research laboratory methods for screening of anti-sapstain formulations
1999 - IRG/WP 99-20170
Two laboratory methods for screening of anti-sapstain formulations were compared. The method adopted by the Forest Research Institute Malaysia (FRIM) involved 3 weeks assessment of rubberwood (Hevea brasiliensis) blocks, dipped in the candidate formulation and inoculated with mycelial/spore suspension of sapstain (Botryodiplodia theobromae) or decay (Schizophyllum commune) fungi, and incubated on ...
A H H Wong, D R Eden, C M Chittenden, M E Hedley, R N Wakeling


Sulfluramid, a new bait concept for the control of termites
1995 - IRG/WP 95-30075
The annual cost of preventing, controlling and repairing the damage done by termites in the United States of America is in the billions of dollars. Current termite control methodology is generally effective in the control of termite activity. However, new technology (termite foams, termite baits, physical barriers) is emerging which has or will provide new tools to control termites. This report ce...
J B Ballard, T K Porter


Leaching of active components from preservative-treated timber. Stages 2 & 3: Laboratory testing and comparison with semi-field testing
2004 - IRG/WP 04-20303
This part of the project is focussed on leaching from preservative-treated wood obtained by the laboratory test method CEN/OECD draft guideline, February 2003 ”OECD guideline for the testing of chemicals proposal for new guideline XXX. Estimation of Emissions from Preservative-treated Wood to the Environment: Laboratory Method for wood held in the storage yard after treatment and for wooden comm...
N Morsing, B Lindegaard


A comparison between high and conventional incision densities for improving preservative treatment of Douglas-fir heartwood lumber
1993 - IRG/WP 93-40009
Incising is required for the preservative treatment of most wood species from the western United States; however, there is considerable debate about the density of incisions required to achieve adequate treatment. Previous studies have shown that the incision effect on treatment is relatively narrow, suggesting that incision densities should be significantly increased over current practices and st...
S T Lebow, J J Morrell


Clean creosote - its development, and comparison with conventional high temperature creosote
1983 - IRG/WP 3235
Pigment emulsified creosote (PEC) is presently being tested and shows considerable stability in terms of water content, pigment level, pH, viscosity, rheological behaviour and microscopy. Timber samples from several eucalypt species have been treated with PEC and side matched samples treated with conventional high temperature creosote (HTC). The PEC treated specimens showed higher weight retention...
C W Chin, J B Watkins, H Greaves


International collaborative laboratory comparison of two wood preservatives against subterranean termites: Second update
1995 - IRG/WP 95-10117
As was agreed by members at the termite workshop at the 24th annual meeting of IRG in Orlando, USA, in May 1993 to initiate an international subterranean termite laboratory bioassay to compare the various preferred termite protocols used by IRG termitologists was initiated. The author was nominated to co-ordinate this comparative laboratory evaluation of two wood preservatives (CCA and Cu-naphthen...
J R J French


Leaching from CCA-treated wood submerged in seawater: Effect of high loadings, and a comparison between laboratory and marine conditions
1996 - IRG/WP 96-50080
This study of leaching examined the following variables: CCA loading; marine versus laboratory exposure and length of submergence. Blocks of Pinus sylvestris were treated to a range of nominal retentions from 15 to 50 kg/m³. Each block was then divided into three cubes and all transverse faces were sealed. All cubes were allowed to fix at ambient temperature for a minimum of one week. One set of ...
R M Albuquerque, S M Cragg, J D Icely


Fungicidal properties of wood tar being a side product of pyrolysis of previously treated wood with preservatives
2004 - IRG/WP 04-30340
The objective of the paper was to estimate the limit of the fungicidal value of wood tar being a product of pyrolysis of wood previously treated with creosote oil or salt preservative of the CCB type. The effectiveness of wood tar in wood protection against fungi causing brown rot and soft rot was compared to the effectiveness of creosote oil (type WEI-B). Wood was impregnated with alcohol solutio...
B Mazela, M Kielczewski, W Grzeskowiak


Comparison of two laboratory methods for screening potential anti-sapstain chemicals
1993 - IRG/WP 93-10036
Two methods were used to screen a number of potential anti-sapstain chemicals in the laboratory. In one method miniature boards of freshly felled Scots pine sapwood were dip treated with the candidate chemical, sprayed with a suspension of stainers or moulds and incubated for five weeks. In the other method antibiotic assay discs were treated with precise quantities of chemical, plated out on malt...
S M Gray, D J Dickinson


Screening wood preservatives: Comparison of the soil block, agar block and agar plate tests
1993 - IRG/WP 93-20001
Several test procedures have been developed over the years to screen potential biocides for their value as wood preservatives. Each test has inherent advantages and disadvantages. In this paper the relative merits of the soil block, agar block and agar plate tests are compared. Eight commercially available biocides encompassing inorganic and organic systems were tested against four basidiomycete d...
K J Archer, D D Nicholas, T Schultz


Comparison of the in-ground performance of pigment emulsified creosote (PEC) and high temperature creosote (HTC)
2000 - IRG/WP 00-30217
A long-term field trial was conducted in Australia to compare the in-ground performance of two oil-borne preservative formulations, conventional high temperature creosote (HTC) and a modified creosote formulation, pigment emulsified creosote (PEC). Three retentions (50, 100 and 200 kg/m³) were targeted for each formulation. An additional retention of PEC formulation (308 kg/m³), which contained ...
J W Creffield, H Greaves, N Chew, N K Nguyen


Comparison of Temporal Changes in Metal Leaching and Aquatic Toxicity from Wood Treated with CCA and Alternative Preservatives
2005 - IRG/WP 05-50236
This study compares the temporal variation of chemical leaching and aquatic toxicity of wood treated with chromated copper arsenate (CCA) and other copper-based wood preservatives (alkaline copper quaternary (ACQ), copper boron azole (CBA), copper citrate (CC) and copper dimethyldithiocarbamate (CDDC)). Treated wood blocks were leached for 21 days and the leachate collected was analyzed for prese...
B Dubey, T G Townsend, G Bitton, H M Solo-Gabriele


Comparison of various types of bait containers designed to aggregate large numbers of foraging subterranean termites from natural populations in below-ground mound colonies
1995 - IRG/WP 95-10116
At Walpeup in the semi-arid mallee country of north-west Victoria (350 km from Melbourne), there are several indigenous subterranean termite species, none of which build above-ground mound colonies but build their colonies below-ground and/or in trees. This paper describes a baiting experiment in which three types of bait containers were compared in their ability to aggregate large numbers of fora...
J R J French, B M Ahmed


Comparison of the inhibitory effects of borate, germanate, tellurate, arsenite and arsenate on 6-phosphogluconate dehydrogenase
1991 - IRG/WP 1508
Sodium borate inhibits the enzymatic activity of many dehydrogenases, and it is thought that this is due to the complexation of the borate anion with the coenzyme nucleotide. It has been suggested in the past that complexation of this type, leading to enzyme inhibition and other biological effects, is responsible for the inhibition of fungal growth and consequently the protection of boron treated ...
J D Lloyd, D J Dickinson


A comparison of analytical techniques
1995 - IRG/WP 95-20061
This paper compares carefully-controlled weight retentions and analysis by XRF, ICP, combustion methods and a new extraction procedure for the new preservative, Copper(II) Dimethyldithiocarbamate (CDDC). Various experimental parameters such as particle size and drying conditions were investigated. In general, the correlations between and among the procedures are very high. The extraction-colorimet...
A C Gallacher, C R McIntyre, M H Freeman, D K Stokes, W B Smith


Comparison of permethrin and fenvalerate as termiticides and their significance to Australian Quarantine Regulations
1984 - IRG/WP 1230
This paper reports detailed laboratory evaluations of the termiticidal efficacy of permethrin and fenvalerate-treated wood blocks. Comparison between artificially wheathered permethrin-treated blocks and unweathered blocks is given. The effect of a 6-week soil burial period on pyrethroid-treated blocks at a retention of 0.08 kg/m³ is also reported. Toxic or protection threshold values for the two...
J W Creffield, C D Howick


Comparison of the anti-fungal efficacy of Cobra with drill perforation on oscillating pressure treated spruce transmission poles -Laboratory test
1988 - IRG/WP 3469
A laboratory method for measuring the depth of penetration of the fungicidal concentrations effective against basidiomycetes (brown rot) was developed. The tests on CCB oscillating pressure treated spruce transmission poles have shown that the depth of salt penetration can be increased by about 10 mm by a drill perforation before the impregnation. An even better penetration is reached, however, if...
E Graf, B Zgraggen


Comparison of thermally modified wood originating from four industrial scale processes – durability
2002 - IRG/WP 02-40229
This study examined the differences in biological wood properties of heat treated wood originating from four different European industrial heat treatment plants. The manufacturers of heat treated material were: PLATO Hout B.V./Netherlands, Thermo Wood/Finland, New Option Wood/France and Menz Holz/Germany where Oil-Heat treated Wood (OHT) is produced. The results of miniblock tests with basidiomyc...
C R Welzbacher, A O Rapp


International comparison of three field methods for assessing the in-ground resistance of preservative-treated and untreated wood to termites and fungal decay – Summary of observations after five years
2003 - IRG/WP 03-20261
Results are presented from a five-year study conducted in five locations in Australia, Thailand and the USA. Three methods of exposure were assessed (below-ground, graveyard and ground contact) for evaluating the in-ground termite and decay resistance of Pinus radiata D. Don sapwood stakes that had been vacuum pressure impregnated with CCA (Type C) and ACQ (Type D) each at two nominal retentions (...
M Lenz, J W Creffield, T A Evans, B M Kard, C Vongkaluang, Y Sornnuwat, A F Preston


A comparison of the leaching resistance of copper 2-ethanolamine and copper ethylenediamine treated Scots pine
2000 - IRG/WP 00-30233
The depletion of copper from copper 2-ethanolamine and copper ethylenediamine treated Scots pine blocks was investigated. A greater leaching resistance was found for copper 2-ethanolamine, which retained ca. 86% and ca. 50% copper after water and buffer leaching, respectively. Leached amine treated blocks also contained significant residual amine. This was consistent with other observations linked...
Xiao Jiang, J N R Ruddick


Some fundamental thoughts on the prediction of field performance from lab-testing based on comparison of lab and field test results of some copper-free materials
2003 - IRG/WP 03-20269
In the paper results from lab testing (ENV 807 and EN 113) are compared with field results (EN 252) of differently treated wood. Depending on the type of the organic biocide containing material and depending on type of soil and type of decay differences were found in suitability of the lab methods to predict field performance. The attempt is made to interpret the found differences. Furthermore it ...
A O Rapp, U Augusta


A comparison of the diffusion of boron from two types of solid preservative rods into the heartwood of 3 Eucalypt pole species
2000 - IRG/WP 00-30227
The ability of boron to diffuse from polyborate and boron/fluoride rods through the heartwood of three eucalypt pole species (blackbutt, red ironbark and spotted gum) was examined. The aim was simply to determine the effects of rod type, wood species and time on the longitudinal diffusion of boron in eucalypt heartwood. Rapid diffusion of boron from polyborate or boron/fluoride preservative rods o...
P J Beutel, P D Evans


Enzyme immunoassay to detect Postia placenta in field tests: Comparison of plate ELISA with hydrophobic cloth and cotton dipstick
1991 - IRG/WP 2378
Standard indirect enzyme-linked immunosorbent assay in polystyrene 96-well plates was compared to hydrophobic polyester cloth and cotton dipstick for detection of wood-derived antigens from the brown-rot fungus Postia placenta. The ease of handling, larger surface area, and economics of the latter two adsorbents were surveyed for application as field tests for detection of early decay. At high ant...
C A Clausen


Laboratory versus field tests for evaluating wood preservatives: A scientific view
1995 - IRG/WP 95-20076
The relative merits of field tests versus laboratory tests for evaluating wood preservatives are discussed. Many of the problems involved in interpretation of the results are similar for both types of test. One major problem is to select field sites or laboratory tests that are representative for the practical use of treated timber in ground contact. Decay tests with treated wood in unsterile soil...
T Nilsson, M-L Edlund


Previous Page | Next Page