IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 655 documents. Displaying 25 entries per page.


Estimating the age of subterranean termite attack and damage in buildings
2010 - IRG/WP 10-10727
This paper describes physical and experimental methods and a mathematical model (Rotramel 2003) to assist in estimating the age of subterranean termite attack and damage to building structures. Timber, building and termite management industries have to develop new strategies to assess and estimate termite attack and damage in the current climate of global warming. A case study will be used as an e...
J R J French, B M Ahmed Shiday, J Thorpe


Termite legislation in France: Termite control measures and prevention rules in building construction
2010 - IRG/WP 10-20448
Reticulitermes subterranean termites are considered as urban pests in France because they are harmful for wood-based in the South and the southwestern quarter of the country. Since November 2006 new protective measures of building construction have been introduced by the French parliament which must be applied across the country and in overseas territories to prevent termite infestations. All new ...
M Kutnik, M Jequel, I Paulmier, D Ansard


Effect of Nano and Micronized Particles as Wood Preservatives for Termite Control
2013 - IRG/WP 13-30620
Subterranean termites are a major factor in the biodegradation of wood constructor products. In this study the efficacy of wood treated with micronized copper, zinc oxide and their mixture was compared to that of wood treated with soluble amine copper oxide with subterranean termites in a laboratory test. All of the formulations tested were effective in controlling wood degradation by the termites...
M Akhtari, D Nicholas, A Rowlen, M Arefkhani


Effect of Nano and Micronized Particles as Wood Preservatives for Termite Control
2013 - IRG/WP 13-30620
Subterranean termites are a major factor in the biodegradation of wood constructor products. In this study the efficacy of wood treated with micronized copper, zinc oxide and their mixture was compared to that of wood treated with soluble amine copper oxide with subterranean termites in a laboratory test. All of the formulations tested were effective in controlling wood degradation by the term...
M Akhtari, D Nicholas, A Rowlen, M Arefkhani


Termite Management and the U.S. Experience: A Case for Wood Treatment & Integrated Control
2015 - IRG/WP 15-30678
A brief overview of termite control is given using specific experiences from the U.S.A. Five major types of termite treatment now prevail: soil applied chemical barriers, in-structure chemical barriers (in-situ applied wood and foundation treatments), physical barriers, treated wood and termite baits. In general, ‘stand-alone’ pretreatments or ‘primary’ treatments are often discussed and ...
J D Lloyd, K van den Meiracker


Subterranean termite control management in urban areas in Spain. Example of management in the old town of Vigo, Spain
2023 - IRG/WP 23-11006
Termites are wood destroying insects always present in the nature with an important wood decomposition function. In Europe, they are mainly located in the Mediterranean area. In Spain, termites are an important problem in urban areas. It is estimated about 80% of old historic towns in Spain are affected by subterranean termite attacks and it is the most important damage in wood structures and wood...
D Lorenzo, A Lozano, M Touza, J Benito


Control of Asian subterranean termites Coptotermes gestroi (Blattodae: Rhinotermitidae) by a new generation bait system with vegetal extracts-diflubenzuron mixture
2023 - IRG/WP 23-30797
The efficacy of anti-termite bait pebble dosed at 0.3% w/w of Diflubenzuron, and Chitin Synthesis Inhibitor (CSI) and 0.6% w/w of vegetal extract from Berkem Biosolutions®, was evaluated in the laboratory on the Asian subterranean termite Coptotermes gestroi (Wasmann). Four concentrations 33.3%, 50%, 50% bis and 100% as well as two neutral matrices, were used in two in-house developed test method...
F Chopinet, D Messaoudi


Comparative response of Reticulitermes flavipes and Coptotermes formosanus to borate soil treatments
1991 - IRG/WP 1486
Eastern (Reticulitermes flavipes [Kollarl]) and Formosan (Coptotermes formosanus Shiraki) subterranean termite workers (Isoptera: Rhinotermitidae) were exposed to borate-treated sand in an indirect exposure tunneling assay in the laboratory. In the ten day assay period, both termite species readily penetrated sand containing 5000, 10000, or 15000 ppm (wt. of compound / wt. of sand) disodium octabo...
J K Grace


Termite standards questionnaire survey. Second Report
1989 - IRG/WP 1395
Information contained in replies received from IRG members responding to the survey continue to be summarised. Again, highlighted in this second report are the major termite species in the various zoogeographical regions, their damage ranking to timber-in-service, the chemicals used in control methods, and the status of the termite standards in the respondent countries....
J R J French, J P La Fage


Laboratory evaluation of chemicals as termiticides
1986 - IRG/WP 1293
Laboratory procedures are described for screening chemicals against subterranean termites. Fast-acting compounds with persistent termiticidal activity are identified in tests using a soil substrate, and slower-acting bait toxicants are evaluated in a series of tests using cellulose substrates....
S C Jones


Response of the Formosan Subterranean Termite (Coptotermes formosanus) to Cellulose Insulation Treated with Boric Acid in Choice and No-Choice Tests.
2004 - IRG/WP 04-10532
The tunneling ability of the Formosan subterranean termite Coptotermes formosanus Shiraki through a cellulose insulation material containing11.1% boric acid was tested in choice and no-choice bioassays. We examined tunneling behavior and mortality of termites exposed to treated and untreated insulation material in miniature simulated wall voids. In a choice test termites tunneled through untreat...
M E Mankowski, J K Grace


What can DNA fingerprinting, aggression tests and morphometry contribute to the identification of colonies of the Formosan subterranean termite
2000 - IRG/WP 00-10371
Multilocus DNA fingerprinting, aggression tests and morphometry were compared to evaluate their potential for the identification of colonies of the Formosan subterranean termite, Coptotermes formosanus (Isoptera: Rhinotermitidae) in Hawaii. DNA fingerprinting separates the termites from all studied collection sites. Since the genetic similarity between termites from different collection sites lies...
C Husseneder, J K Grace


Termite standards questionnaire survey
1987 - IRG/WP 1324
J R J French, J P La Fage


Studies on the foraging of subterranean termites
2000 - IRG/WP 00-10345
To study the foraging galleries of subterranean termites in soil, early researchers painstakingly excavated underground tunneling system of these cryptic insects. Erhorn (1934) listed a report by Oahu Sugar Co., Ltd. in 1928 showing that runway of Coptotermes formosanus may extend up to 50 m long and 0.3 - 3 m deep. Ratcliffe & Greaves (1940) who excavated foraging galleries of Coptotermes lac...
N-Y Su


Development of a Granitgard® particulate termite barrier for use in tropical Australia
1997 - IRG/WP 97-10190
Granitgard® is superficially simple technology; graded crushed aggregate, sieved to a size range impenetrable to subterranean termites. However, behind this apparent simplicity lies a large research effort. In this paper we describe the laboratory development of a grading of Granitgard suitable for use against the wide range of termites which attack timber in northern Australia, above the Tropic ...
D M Ewart, E R Rawlinson, A D Tolsma, G C Irvin, P R Wiggins


Evaluating the Exterra Termite Interception and Baiting System in Australia
2003 - IRG/WP 03-20267
The Exterraä Termite Interception and Baiting System (Ensystex Inc., Fayetteville, NC) was evaluated in a field experiment near Townsville, Australia. Cellulose-acetate powder containing either 0.05% weight/weight (w/w) or 0.25% w/w chlorfluazuron (Requiemä) was tested for its efficacy in eradicating colonies of the mound-building subterranean termite Coptotermes acinaciformis (Froggatt). Thirte...
B C Peters, S Broadbent


Differences in feeding activity among colonies of Formosan subterranean termite Coptotermes formosanus Shiraki
1983 - IRG/WP 1202
Feeding activities of 7 colonies of the Formosan subterranean termite, Coptotermes formosanus Shiraki, were examined. Wood-consumption rates among colonies differed significantly, ranging from 23.80-78.48 mg/g/day. This large intraspecific variation raised a question of whether differences in feeding activity reported for other termite species were due to interspecific differences. When rates were...
N-Y Su, J P La Fage


A critical review of the AWPA standard method (M12-72) for laboratory evaluation to determine resistance to subterranean termites
1986 - IRG/WP 1298
The American Wood Preservers' Association standard (M12-72) for evaluation of candidate wood preservatives against subterranean termites is reviewed and suggestions for revision are made. The most serious flaws in the current test procedure involve a failure to recognize inter- and intraspecific variation and a lack of quantification of test results....
J P La Fage, M Jones


Treatment of Douglas fir heartwood with disodium octaborate tetrahydrate (Tim-BorÒ ) to prevent attack by the Formosan subterranean termite
1991 - IRG/WP 1487
Toxicity of disodium octaborate tetrahydrate (Tim-BorÒ) to Coptotermes formosanus Shiraki (Isoptera: Rhinotermitidae), and termite feeding on treated Douglas-fir heartwood were evaluated in laboratory and field tests. Feeding on filter papers impregnated with Tim-BorÒ solutions reduced but did not eliminate termite gut protozoan populations. In a forced-feeding laboratory assay, Douglas-fir hear...
M Tamashiro, R T Yamamoto, J K Grace


Biocides - Efficacy assessment and doses for wood preservatives (product type 8). Local/geographical aspects. Termite control as case study
1999 - IRG/WP 99-20181
Currently, the efficacy of a wood preservative, as biocidal product type 8, is assessed as a ‚critical value' (CV), an efficient dose (retention in wood at a given depth of penetration). CVs are planned to be adapted for exposure to basic target organisms (5 hazard classes) and additional requirements concerning the occurrence of local target organisms in relation with climate, building...
G Ozanne


Evaluation by experimentation on site of a new method for termite control
1996 - IRG/WP 96-10173
A new concept of subterranean termite control consists of the installation of toxic baits in or around the infested construction. Dow Elanco has developed a bait system based on Hexaflumuron. This active ingredient is an insect growth regulator with slow acting effect. A lot of trials were conducted in the USA, but none in France until now. We realised on site experiments, in order to estimate the...
A-M Pruvost, M-M Serment, M Jéquel


Termites in Eastern Canada: An updated review and bibliography
1990 - IRG/WP 1431
This report updates Document No. IRG/WP/1333, issued in 1987. The current distribution of termites in eastern Canada and current termite control practices and controversies are explained, and current research is very briefly summarized. Since 1987, Reticulitermes flavipes (Kollar) (Isoptera: Rhinotermitidae) has been discovered in several more municipalities in the province of Ontario, and in Winn...
J K Grace


Tunneling ability of subterranean termites through termiticide-treated soil
1988 - IRG/WP 1375
A test apparatus was designed to facilitate accurate measurement of termite penetration into termiticide-treated soil; three termiticides at 500 ppm were evaluated. Coptotermes formosanus Shiraki workers tunneled significantly farther into chlordane-treated soil than did Reticulitermes flavipes (Kollar). Both species only slightly penetrated chlorpyrifos-treated soil. Neither species penetrated so...
S C Jones


Justification for use of mirex in termite control
1988 - IRG/WP 1346
In August 1987, organochlorines were withdrawn in North America from use in termite control. This has left the industry and the community with reduced options in long term protection of wood and wood products. A case is presented to justify the use of the slow-acting stomach termiticide, mirex, under special permit, for use only in the bait-block method of termite control. This method, while not a...
J R J French


Termite standards questionnaire survey - First Report
1988 - IRG/WP 1354
Information contained in replies received from IRG members responding to the termite standards questionnaire survey are summarised. Highlighted in the results of this first report are the major termite species in the various zoogeographical regions, their damage ranking to timber-in-service, the chemicals used in control methods, and the status of termite standards in the respondent countries....
J R J French, J P La Fage


Previous Page | Next Page