IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 437 documents. Displaying 25 entries per page.


Evaluation of the Virulence of the Termite Species Occurring in the French Tropical Overseas Territories
2018 - IRG/WP 18-10913
The French tropical overseas territories are strongly affected by termites’ activity, which is especially devastating because the species encountered there are among the most virulent in the world. That is why in these regions it is particularly important that producers and users of wood-based products are provided with materials and preservative products whose durability and efficacy has been t...
M Kutnik, I Paulmier, J Vuillemin


Comparative response of Reticulitermes flavipes and Coptotermes formosanus to borate soil treatments
1991 - IRG/WP 1486
Eastern (Reticulitermes flavipes [Kollarl]) and Formosan (Coptotermes formosanus Shiraki) subterranean termite workers (Isoptera: Rhinotermitidae) were exposed to borate-treated sand in an indirect exposure tunneling assay in the laboratory. In the ten day assay period, both termite species readily penetrated sand containing 5000, 10000, or 15000 ppm (wt. of compound / wt. of sand) disodium octabo...
J K Grace


Problems caused by termites in buildings in the State of Sao Paulo
1976 - IRG/WP 150
Termites are the main insects attacking buildings in the State of Sao Paulo - Brazil. Their attack occurs in wood and wooden materials as well as paper, textile, leather and so on....
M S Cavalcante


An evaluation method for less termite attack execution on thermal insulation for fundation walls
2002 - IRG/WP 02-20245
According to the results by the real scale Japanese building tests, the termite installation was observed at very little spaces between foundation and insulation. The termite penetration spaces between foundation and insulation on foundation systems in Japanese wooden houses were checked by the way of streaming speed of colored water. Because of difficulty for its execution, the parts of outside a...
K Suzuki, Y Tanaka


Physical barriers and bait toxicants: The Romeo and Juliet of future termite control
1991 - IRG/WP 1503
Soil chemical barriers are considered by some to be the most important technique for protecting buildings against subterranean termites in Australia (and elsewhere), providing a barrier against termite penetration. However, there is no such thing as a barrier that is 100 per cent +protective. And given the worldwide problems of using organochlorine termiticides, public awareness of chemical pollut...
J R J French


Report and recommendations of the National Termite Workshop held in Melbourne on the 17 April 2002.
2003 - IRG/WP 03-10478
There are two parts to this Report. Part One summaries the outcomes of an industry workshop organised to better scope the subterranean termite problem, identify knowledge gaps including R&D gaps and identifying strategies including cost-effective co-ordination mechanisms for addressing the issue. Part Two is a brief review of the current state of knowledge on subterranean termites of economic ...
B M Ahmed, J R J French


Termite standards questionnaire survey. Second Report
1989 - IRG/WP 1395
Information contained in replies received from IRG members responding to the survey continue to be summarised. Again, highlighted in this second report are the major termite species in the various zoogeographical regions, their damage ranking to timber-in-service, the chemicals used in control methods, and the status of the termite standards in the respondent countries....
J R J French, J P La Fage


Trials on the field control of the Formosan subterranean termite with Amdro® bait
1982 - IRG/WP 1163
Amdro® - treated paper towels were introduced into two field colonies of the Formosan subterranean termite in Hawaii. At the concentration of 180 ppm, the toxicant bait was ineffective one month after the introduction. At higher concentrations (> 6,400 ppm), the baits were eaten initially; however, one week after introduction, termites avoided or covered the baits. The 15,000 ppm baits supress...
N-Y Su, M Tamashiro, J R Yates III


Termite resistance of pine wood treated with chromated copper arsenates
1997 - IRG/WP 97-30128
Two four-week, no-choice laboratory tests were performed with CCA-treated southern yellow pine and radiata pine against Formosan subterranean termites, Coptotermes formosanus. CCA retentions as low as 0.05 kg/m3 (0.03 pcf) provided protection from all but light termite attack (rating of 9 on a 10-point visual scale). Similar and consistent light attack on wafers containing retentions as high as 6....
J K Grace


Termite trail-following substances in Houttuynia cordata
2001 - IRG/WP 01-10409
Termite trail-following active compounds in the plant, Houttuynia cordata Thunb., were studied by a combination of chemical analyses and bioassay using Coptotermes formosanus Shiraki as a test termite. We have found that termites were attracted to methanol extracts from H. cordata. The n-hexane(Hex) extracts, that showed a trail-following activity, were fractionated by a silica-gel column chromato...
W Ohmura, K Yamamoto, M Saegusa, T Ohira, A Kato


Evidence supporting the use of termite baiting systems for long-term structural protection
2000 - IRG/WP 00-10377
The efficacy of the Sentricon Colony Elimination System containing Recruit II termite bait (0.5% hexaflumuron) in controlling active subterranean termite infestations has been demonstrated in numerous studies. This baiting system and other termite baiting systems are now widely used, and generally accepted, tools for remedial termite control in North America, Hawaii, and other parts of the world. ...
J K Grace, N-Y Su


Leaching of components from water-borne paints and fungitoxic effects
1995 - IRG/WP 95-20062
Water-borne model paints, acrylics and alkyd emulsion paints, of known composition were leached according to a procedure modified in accordance with ASTM 6271.1. The effectiveness of fungicidal compounds in the painted specimens before and after leaching was evaluated with a biotest in which Penicillium brevicompactum was used as a test fungus. The leaching of the fungicide Troysan Polyphase accor...
J Bjurman


Physical and biological properties of albizzia waferboards modified with cross-linking agents
1995 - IRG/WP 95-40043
Chemically-modified low-density waferboards with cross-linking agents were produced using a fast-growing species of hardwood albizzia (Paraserienthes falcata Becker) as a raw materials and isocyanate resin as a glue adhesive. For the chemical modification, the vapor-phase formalization of the boards and the pad-dry-cure treatment of wafers with cross-linking agents were employed. The vapor-phase f...
S Yusuf, Y Imamura, M Takahashi, K Minato


Laboratory evaluation of chemicals as termiticides
1986 - IRG/WP 1293
Laboratory procedures are described for screening chemicals against subterranean termites. Fast-acting compounds with persistent termiticidal activity are identified in tests using a soil substrate, and slower-acting bait toxicants are evaluated in a series of tests using cellulose substrates....
S C Jones


Biological control of the Formosan subterranean termite Coptotermes formosanus Shiraki
1971 - IRG/WP 100
M Tamashiro, J K Fujii, P Lai, T E Richardson


A direct method for testing plywood and particle boards against fungal decay
1984 - IRG/WP 2214
A method directly inspired from the French standard testing method of the resistance of particle boards against fungal decay (AFNOR N° 51.295 May 1980) is described. But in that experimentation, the infestation is localized and realized in non sterile conditions. Small blocks of Fagus sylvatica (60 x 20 x 10 mm³) used as " inoculates " are infested with basidiomycetes, in Kolle flask for 4 to 6 ...
L N Trong


Response of the Formosan Subterranean Termite (Coptotermes formosanus) to Cellulose Insulation Treated with Boric Acid in Choice and No-Choice Tests.
2004 - IRG/WP 04-10532
The tunneling ability of the Formosan subterranean termite Coptotermes formosanus Shiraki through a cellulose insulation material containing11.1% boric acid was tested in choice and no-choice bioassays. We examined tunneling behavior and mortality of termites exposed to treated and untreated insulation material in miniature simulated wall voids. In a choice test termites tunneled through untreat...
M E Mankowski, J K Grace


A method for screening termite baits using Coptotermes lacteus mounds
1984 - IRG/WP 1237
A method with several variations designed to rapidly screen potential bait substrates using Coptotermes lacteus mounds is described. The equipment used in this method is relatively inexpensive, readily prepared in the laboratory, and easily installed into active mounds in the field. Bait substrates are in continuous contact with a 'high termite hazard', and may be monitored with ...
J R J French, P J Robinson


What can DNA fingerprinting, aggression tests and morphometry contribute to the identification of colonies of the Formosan subterranean termite
2000 - IRG/WP 00-10371
Multilocus DNA fingerprinting, aggression tests and morphometry were compared to evaluate their potential for the identification of colonies of the Formosan subterranean termite, Coptotermes formosanus (Isoptera: Rhinotermitidae) in Hawaii. DNA fingerprinting separates the termites from all studied collection sites. Since the genetic similarity between termites from different collection sites lies...
C Husseneder, J K Grace


Preliminary attempts towards the development of a small scale termite rearing chamber. Progress report
1983 - IRG/WP 1203
The results suggest that there is no evidence that the volume of the rearing chamber plays a part in the settlement of a colony. These rearing chambers present a factor of productivity (final enumeration)/(initial enumeration) of roughly 2 after one year. 90% of the colony survived. This method of breeding can be considered as feasible and cheap....
M Argoud, J C Palla, R Sternalsky


Termite standards questionnaire survey
1987 - IRG/WP 1324
J R J French, J P La Fage


Termite researcher questionnaire
1985 - IRG/WP 1274
J P La Fage


Sequential exposure of borate treated Douglas-fir to multiple Formosan subterranean termite colonies in a 40-week field test
1993 - IRG/WP 93-10006
Douglas-fir boards (ca. 74.5 g) pressure-treated with disodium octaborate tetrahydrate (DOT) retentions of 0 (controls), 0.88, 1.23, 1.60, or 2.10% (weight/weight) DOT were sequentially exposed to four active field colonies of Formosan subterranean termites, Coptotermes formosanus Shiraki (Isoptera: Rhinotermitidae), in an above-ground field test. Samples were placed in contact with each colony fo...
J K Grace, R T Yamamoto


Results on termite resistance of building materials against Coptotermes formosanus by choice test
1998 - IRG/WP 98-10275
Various building materials, included wood species, wooden board materials, thermal insulation materials and fire-protection materials, were tested for grading of termite resistance against Coptotermes formosanus. The dimension of most specimens were 2x2x2cm3. Ten repeats were prepared. The specimens were put between Akamatsu sapwood control specimens on a laboratory cultured mound colony of termit...
K Suzuki, K Hagio


Studies on the foraging of subterranean termites
2000 - IRG/WP 00-10345
To study the foraging galleries of subterranean termites in soil, early researchers painstakingly excavated underground tunneling system of these cryptic insects. Erhorn (1934) listed a report by Oahu Sugar Co., Ltd. in 1928 showing that runway of Coptotermes formosanus may extend up to 50 m long and 0.3 - 3 m deep. Ratcliffe & Greaves (1940) who excavated foraging galleries of Coptotermes lac...
N-Y Su


Previous Page | Next Page