IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 84 documents. Displaying 25 entries per page.


Computerized axial tomography. A non-destructive method for three-dimensional wood density/moisture content measurement
1987 - IRG/WP 2285
Computerized Axial Tomography (CAT-scanning) - used for medical investigations of the brain - has been evaluated as a nondestructive method of three-dimensional wood density/moisture content measurements. Density can be measured with an accuracy of ±3 kg/m³, and the accuracy in average moisture content is ±1% below and above fibre saturation point. It is theoretically possible that measurements...
L O Lindgren


Application of non-destructive techniques (durometric and ultrasonic) to evaluate the degradation of woods in service by Gloeophyllum trabeum
2001 - IRG/WP 01-20220
In order to establish the degree of degradation of wood used in construction, it is necessary to employ non-destructive methods (ultrasonic, durometric, densitometric). In this study, ultrasonic and Pilodyn durometric techniques have been applied to try to establish parameters of relationship between the values obtained by both, for their immediate application to wood in service. As a method of re...
M T De Troya, L Palaia, A Navarrete, V Galvañ, R Molina, A Guijarro, J Camacho


NMR T1 relaxation time as a non-destructive method for the study of decay in wood
1992 - IRG/WP 92-2406
The NMR spectroscopic technique of measuring the T1 spin-lattice relaxation times has been investigated for its potential in the detection of microbial decay in wood. The T1 NMR analyses were carried out on samples of Scots pine and European beech that had been exposed to decay and non-decay fungi representing each of the important groups colonising wood. Decay in the test material was also assess...
P W McCormack, A E G Cass, R J Murphy


Arbeitsverfahren zum Herstellen und mikroskopischen Auswerten von Dünnschnitten aus Holz-Bohrkernen. [Working method for producing and evaluating microscopically thin cuts of bore samples]
1980 - IRG/WP 2133
Bore samples are important specimens; e.g. they are in use to investigate poles in service. On the basis of known methods of microtomy a technique is described which permits the production of longitudinal cuts from bore samples. For this purpose, the bore sample is glued onto a mounting; the surface of cut is coated with a polystyrene solution. The cut thus consolidated can be stained, drained, an...
S Cymorek


New methods for nondestructive inspection of timber in buildings
1995 - IRG/WP 95-20070
In these years older buildings are renewed in most European countries on a large scale, and new techniques are needed for both inspection and eradication of fungal attacks. Heat treatment as a means of eradicating the dry rot fungus has been used in Denmark during the last decade. This technique minimises the structural damage to the building, whilst at the same time reducing costs by up to 50%. T...
B Madsen, O V Frederiksen


Evaluation of bending strength by non-destructive methods of Ezomatzu with white pocket rot
1991 - IRG/WP 2371
The possibility of application of three non-destructive methods was examined for evaluation of bending strength of ezomatsu (Picea jezoensis CARR.) with white pocket rot. As non-destructive methods, the measurements of ultrasonic wave propagation time, impact-induced stress wave propagation time and penetration depth of pin of "PILODYN Wood Tester" were applied to compare with visual evaluation of...
T Tanaka


Termatrac: microwave technology for non-destructive detection of insect pests in timber
2002 - IRG/WP 02-20253
Termatrac is a microwave instrument that has been developed in Australia to detect termite movement within timber and wall cavities. We present data from an investigation into the usefulness of the instrument in detecting drywood and subterranean termites in timber. The West Indian drywood termite Cryptotermes brevis (Walker) was detected in a wooden chair. The subterranean termites Coptotermes ac...
B C Peters, J W Creffield


The potential application of rapid gas-chromatographic assay of microbial respiration to the monitoring of wood decay in field trial situations
1983 - IRG/WP 2196
Gas chromatographic detection of microbial activity (C02 production) within stakes in a field trial situation would appear to provide a sensitive, non-destructive and relatively rapid method for the quantitative assessment of preservative treatments. Most consistent results were obtained when stakes were removed from the soil, washed, saturated with water and incubated in sealed PVC tubes at 25°C...
M A Line


Assessment of the Termatrac™ system - a new microwave based technology for non-destructive detection of termites
2003 - IRG/WP 03-20265
Termites can be difficult to detect reliably and many detection methods are destructive to property or disturbing to the termites (which may interfere with remedial treatment). The reliability of Termatrac™, a new Australian device for the detection of termites in an unobtrusive manner, based on novel microwave technology, was tested in the field. Termite presence was assessed as indicated by th...
T A Evans


Effect of post-treatment drying schedule on the modulus of elasticity of CCA-treated southern pine dimension stock using nondestructive methods
1987 - IRG/WP 3413
This paper describes the results from the nondestructive testing for modulus of elasticity (MOE) of southern pine (Pinus sp.) 2 x 6's treated with chromated copper arsenate and redried using three commercial kiln schedules. The data indicate that redrying CCA-treated southern pine dimension stock treated to above-ground retentions (4 kg/m³) has no deleterious effect on the MOE, regardles...
H M Barnes, S Moore


Nondestructive assessment of biodegradation in southern pine sapwood exposed to attack by natural populations of decay fungi and subterranean termites
1994 - IRG/WP 94-20042
Field methods for evaluating decay resistance of experimentally treated materials lack a means for quantitative measurement of residual strength. Quantitative relationships between speed of impact-induced waves travelling parallel to the grain and residual compressive strength have been demonstrated in softwood attacked by brown rot-decay fungi, but the effects of termites have not been documented...
R C De Groot, R J Ross, W Nelson


Limitations of the Pilodyn when assessing decay in graveyard test stakes
1982 - IRG/WP 2168
The following examination was designed to evaluate more precisely the usefulness of the Pilodyn for routine, objective assessments of the condition of field test stakes and to examine its limitations, particularly in respect to: 1.) The importance of variables other than extent of decay which may affect Pilodyn readings; 2.) Practicality of obtaining multiple readings in decayed and non-decayed re...
M E Hedley


Co-operative research project on L-joint testing. Sampling after 4 years exposure
1987 - IRG/WP 2274
In September 1983, Document No: IRG/WP/2208 was distributed giving guidance on sampling after 8 months exposure and including tables on which to record the test results. Similarly in September 1984, Document No: IRG/WP/2233 was distributed concerning sampling after 18 months exposure. No major problems have been notified to Princes Risborough Laboratory concerning the sampling method. It is theref...
J K Carey, A F Bravery


Chemical analysis of wood waste - The problem of sampling
1999 - IRG/WP 99-20168
A quantitative analysis of the content of active substances in wood is often demanded in quality control after processing and for the proper waste management. As a measure for quality control, analysis has the advantage that the type of preservative is known and assumptions can be made about its distribution in the treated wood.W aste wood may have been treated by a wide range of organic and inorg...
A Peylo, R-D Peek


Permeability measurements on surface layers for detecting wood with abnormally high permeability
1988 - IRG/WP 2298
Wet storage of timber during the warm period of the year may lead to an increased permeability of the wood, an undesirable phenomenon for several wood industries and also for many end-uses. Neither before nor after drying, such wood with "wet storage damage" can be visually distinguished from wood with a normal permeability. A non-destructive method for inspecting the permeability of surface layer...
J B Boutelje, G Hägglund


The effect of moisture content on the electrical resistance of timber as detected by a pulsed current reistance meter (Shigometer)
1984 - IRG/WP 2212
The literature concerning the use of the Shigometer® for detecting decay in standing trees and wood poles is reviewed and the differences of opinion over the effect of timber moisture content on electrical resistance are highlighted. A simple experiment designed to test this effect is described and the implications of the results for testing poles in service are discussed. There was a large diffe...
P I Morris, D J Dickinson


The use of low cost X-ray fluorescence instruments in the determination of copper chromium and arsenic in preservative treated wood
1987 - IRG/WP 2278
Internal quality control in timber treatment plants can be pursued by analysis of preservative treatment solutions and treated timber. Treaters must proceed with costly and lengthy analyses through analytical laboratories. An alternative approach for the timber treater, is to use low cost analysers (L.C.A.'s) based upon x-ray fluorescence. Detailed comparisons have been made between stand...
J Norton, L E Leightley


Examination of power poles by computerized tomography
1980 - IRG/WP 2142
The technique known as computed axial tomography (CAT or CT) has become widely known because of the success it has achieved in medical imaging and diagnostics. It has now been used to give non-destructive crosssectional pictures of a variety of industrial objects, including wooden power poles, with a spatial resolution of about 1 mm (0.04 in.). It is obvious the benefits that would be derived from...
J A Taylor, I L Morgan, H Ellinger


A non-destructive testing technique for wood poles
1987 - IRG/WP 2293
A method has been developed to evaluate the stiffness and condition of a wood pole based on structural dynamics. This paper describes the results of tests performed on nearly 200 wood utility poles across Western Canada. A high correlation exists between the dynamic non-destructive test and direct mechanical tests. The need for an accurate non-destructive testing technique is demonstrated by the f...
W M Murphy, D E Franklin, R A Palylyk


Leaching from field test stakes. Results from two different methods of analysis
1993 - IRG/WP 93-50013
Field test stakes treated with Boliden K33 containing copper, chromium and arsenic exposed at three different fields in Sweden and rejected due to decay, have in two studies been analysed regarding leaching and remaining preservatives. The stakes have been exposed during 20 to 43 years. The density of the stakes and content of copper, chromium and arsenic have been determined in the top part of th...
F G Evans, M-L Edlund


Detection of termite attack in wood using acoustic emission
1989 - IRG/WP 2331
Acoustic emission (AE) is the elastic wave produced by the strain energy released in the process of fracture of a material and propagates through it. The object of this report is to detect AEs produced by the termite activities and to evaluate the possibility of using an AE monitoring test to nondestructively detect the termite attack in wood. It was revealed that AEs were detected from the specim...
Y Fujii, M Noguchi, Y Imamura, M Tokoro


Hole delimination inside round timber via ultrasonic techniques
1990 - IRG/WP 2358
A fast and economic circular scanning method to localize and evaluate holes inside round timber is presented. This method consists in measuring transit times of the ultrasonic wave by fixing the transmitter probe in the perimeter of the sample, then moving the receiver probe every ten degrees until completion of the circle. The scanning is done with a cheap and light instrument. Tests are made wit...
G Prieto, A Fernández Cancio


An Investigation on Use and Durability of Some Industrial and Domestic Woods of Iran against Destructive Factors in Caspian Sea
2008 - IRG/WP 08-10636
In this study the use of domestic and commercial woods of the Caspian Sea forest fringes and evaluation of their durability against marine destructive factors were investigated. The samples of elm (Zelkova carpinifolia), oak (Quercus castanifolia), beech (Fagus orientalis), Maple (Acer insgin), Alder (Alnus subcordata), and horn beech (Carpinus betulus) species were impregnated with CCA (Chrome–...
S M Kazemi


Stress wave and visual analysis of treated and non treated fence posts after 15 years in field test
2010 - IRG/WP 10-20449
Wood preservation may play an important role in protecting tropical rain forest. Basically, it can reduce pressure on natural resources by increasing wood durability. Field tests are conducted to simulate final use of woods under different environmental conditions. Visual analysis, non destructive testing, and non destructive evaluation techniques were applied to assess wood resistance and chemica...
A Florian da Costa, R Faustino Teles, J Costa Gonçalves


Non-destructive evaluation of termite and decay damaged to timber-in- service
2010 - IRG/WP 10-20451
A leading joint research project was financed by the ARC, engaging some of the leading Universities in Australia, to look at field techniques to determine if timber-in-service is infested with termites and decay fungi after which microwave technology will be employed to eliminate the termites and/or decay in-situ. The next step will be to quantify the damage caused on the sectional dimensions of t...
C Adam, B M Ahmed Shiday, G Brodie


Previous Page | Next Page