IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 669 documents. Displaying 25 entries per page.


Termite resistance of borate-treated lumber in a three-year above-ground field test in Hawaii
2000 - IRG/WP 00-30236
A protected above-ground field test simulating the sill plate (dodai) used in conventional Japanese housing construction was established in both Hawaii and Japan to examine the efficacy of disodium octaborate tetrahydrate (DOT, 2% and 3% shell and through) wood treatments. In Hawaii, chromated copper arsenate (CCA, 4 kg/m3) and ammoniacal copper zinc arsenate (ACZA, 4 kg/m3) were included in the t...
J K Grace, R J Oshiro, A Byrne, P I Morris, K Tsunoda


Biocides - Efficacy assessment and doses for wood preservatives (product type 8). Local/geographical aspects. Termite control as case study
1999 - IRG/WP 99-20181
Currently, the efficacy of a wood preservative, as biocidal product type 8, is assessed as a ‚critical value' (CV), an efficient dose (retention in wood at a given depth of penetration). CVs are planned to be adapted for exposure to basic target organisms (5 hazard classes) and additional requirements concerning the occurrence of local target organisms in relation with climate, building...
G Ozanne


Detection of Acoustic Emission (AE) generated by termite attack in a wooden house
1999 - IRG/WP 99-20166
Recently, considerable attention has been paid to methods for termite control, which involves few or no chemicals. To reduce the amount of termiticide needed, it is necessary to detect termite attack in wood as early as possible. The feasibility of acoustic emission (AE) monitoring for the nondestructive detection of termite attack has been discussed previously. In this study, we propose some tech...
Y Fujii, Y Yanase, T Yoshimura, Y Imamura, S Okumura, M Kozaki


International comparison of three field methods for assessing the in-ground termite resistance of materials - highlights after two years
1999 - IRG/WP 99-20157
First-year results of a comparative study, evaluating the in-ground termite resistance of a range of materials, including CCA and ACQ-treated timbers, using the below-ground exposure, ground contact and graveyard methods against diverse termite faunas were provided in IRG/WP/98-20132. Further annual inspections have confirmed early trends and identified notable differences between sites and method...
M Lenz, J W Creffield, A F Preston, B M Kard, C Vongkaluang, Y Sornnuwat


Antifeedant activities of flavonoids and their related compounds against the subterranean termite, Coptotermes formosanus Shiraki
1999 - IRG/WP 99-10305
Antifeedant activities of some flavonoids and their related compounds against the subterranean termite, Coptotermes formosanus Shiraki were examined with no-choice and two-choice tests. The activities of these compounds were considered in relation to their chemical structures. All flavonoids tested showed antifeedant activities whereas catechinic acid without A-ring and pyran ring in the molecule ...
W Ohmura, S Doi, M Aoyama, S Ohara


A real scale evaluation method and results on termite resistance of housing wall systems and floor framings
1999 - IRG/WP 99-10314
For evaluating the termite resistance of real scale houses especially housing wall systems and floor framings, a experimental building was prepared. After initial feeding of termite, this house was constructed. In this experimental building, several parts which were built by different wall systems and floor framing. The room temperature of these parts were controlled. Water can be provided in the ...
K Suzuki, K Okada, K Hagio, Y Tanaka


Results on termite resistance of building materials against Coptotermes formosanus by choice test
1998 - IRG/WP 98-10275
Various building materials, included wood species, wooden board materials, thermal insulation materials and fire-protection materials, were tested for grading of termite resistance against Coptotermes formosanus. The dimension of most specimens were 2x2x2cm3. Ten repeats were prepared. The specimens were put between Akamatsu sapwood control specimens on a laboratory cultured mound colony of termit...
K Suzuki, K Hagio


Attractive factors of steam-treated larch wood to termite feeding
1998 - IRG/WP 98-10256
The hot water extractives from steam-treated Japanese larch wood were studied to understand the chemical properties of attractive factors of the treated wood to feeding behavior of a subterranean termite, Coptotermes formosanus. Hot water extractives were fractionated and analyzed using chromatography, gel filtration, and NMR methods. The stimulants yielded by the steam treatment were comprised o...
S Doi, Y Kurimoto, W Ohmura, M Aoyama, S Ohara


Termite resistance of Malaysian and exotic woods with plantation potential: Laboratory evaluation
1998 - IRG/WP 98-10280
The resistance of selected Malaysian woods to attack by the representative aggressive subterranean termite Coptotermes formosanus Shiraki (Isoptera: Rhinotermitidae) was evaluated in four-week, no-choice laboratory tests. This is part of an ongoing effort between the Forest Research Institute Malaysia and the University of Hawaii to document the termite resistance of Malaysian timber species of po...
J K Grace, A A H Wong, C H M Tome


Comparison of three methods for assessing the in-ground termite resistance of treated timber, durable timber and plastics at sites in Australia, USA and Thailand - First results
1998 - IRG/WP 98-20132
The in-ground resistance of materials to attack by subterranean termites is most commonly assessed with one form or another of the conventional graveyard method, despite the significant shortcomings of this method. In Australia, an alternative method, in which all samples of test materials are placed below-ground, has been in use for more than 10 years. The method provides reliable exposure of sam...
M Lenz, A F Preston, J W Creffield, K J Archer, B M Kard, C Vongkaluang, Y Sornnuwat


Occurrence of termite species on decaying heartwood specimens exposed 18 to 23 years at an Australian site
1998 - IRG/WP 98-10270
The occurrence of species of subterranean termites on hardwood and softwood specimens (including preservative-treated), exposed in-ground at a semi-arid site at Walpeup (north-western Victoria), 18 to 23 years after installation, is reported. This paper presents maps of the cumulative occurrence on specimens, after six annual inspections, of the following species: Coptotermes acinaciformis, Hetero...
J W Creffield, J-D Thornton, G C Johnson


Termite resistance of Malaysian and exotic woods with plantation potential: Field evaluation
1998 - IRG/WP 98-10289
An in-ground resistance of selected Malaysian and exotic timbers to attack by a representative aggressive subterranean Coptotermes termite was evaluated as part of an on-going collaborative research between the Forest Research Institute of Malaysia and the University of Hawaii on termite control of building timbers under humid tropical conditions. A test site at FRIM, highly susceptible to the sub...
A H H Wong, J K Grace, L H Kirton


A novel chemical barrier system, KORDON® TMB, for the protection of buildings against subterranean termites using a synthetic matrix as carrier for the chemical
1998 - IRG/WP 98-10264
Kordon TMB is a new chemical barrier system for installation beneath concrete slab-on-ground constructions using a matrix other than soil as carrier for the termiticide. The product consists of a synthetic foraminous web (blanket) carrying the synthetic pyrethroid deltamethrin. The blanket is laminated on the upper side to a standard 0.2mm thick moisture vapour membrane of low density polyethylene...
M Lenz, P Morrow, S Runko


Termite resistance of pine wood treated with chromated copper arsenates
1997 - IRG/WP 97-30128
Two four-week, no-choice laboratory tests were performed with CCA-treated southern yellow pine and radiata pine against Formosan subterranean termites, Coptotermes formosanus. CCA retentions as low as 0.05 kg/m3 (0.03 pcf) provided protection from all but light termite attack (rating of 9 on a 10-point visual scale). Similar and consistent light attack on wafers containing retentions as high as 6....
J K Grace


Development of a Granitgard® particulate termite barrier for use in tropical Australia
1997 - IRG/WP 97-10190
Granitgard® is superficially simple technology; graded crushed aggregate, sieved to a size range impenetrable to subterranean termites. However, behind this apparent simplicity lies a large research effort. In this paper we describe the laboratory development of a grading of Granitgard suitable for use against the wide range of termites which attack timber in northern Australia, above the Tropic ...
D M Ewart, E R Rawlinson, A D Tolsma, G C Irvin, P R Wiggins


An overview of termite control in buildings in Kenya
1997 - IRG/WP 97-10242
Termites are well known pests of wooden products and structural timber and are responsible for considerable damage in the building sector in sub-Saharan Africa. A general diagnostic survey of damaging termite species in agriculture, forestry and buildings was carried out for the first time in Kenya (1991-1992). Termite species implicated in damage to wooden materials and structural timber in build...
G R S Ochiel, W Gitonga, L Toft


Laboratory evaluation of fipronil (a phenyl pyrazole) as a candidate termiticide in the protection of wood against the subterranean termite, Coptotermes acinaciformis (Froggatt) Rhinotermitidae
1997 - IRG/WP 97-10225
In this laboratory evaluation, radiata pine wood blocks (50 x 25 x 15 mm3) were impregnated with fipronil (a phenyl pyrazole) at various concentrations (0, 5, 10, 20, 40, 80, 100 and 200 ppm). Half the treated blocks underwent a leaching schedule for 5 days, while the remainder were unleached after treatment. Five replicates per treatment regime were presented to the test termite, Coptotermes acin...
B M Ahmed, J R J French, P Kwint, G Webb


Distribution of cellulases in the body of Coptotermes formosanus and the probability that the termite uses glucose as an energy and carbon sources
1997 - IRG/WP 97-10202
We assayed extracts of the digestive system and of the whole body of Coptotermes formosanus to determine where the various cellulases, glucose, and related substances were concentrated and to detect pyruvate dehydrogenase activity in the hindgut-removed body in order to verify its full cellulolytic system. About 20%, 18% and 36% of the total exo-1,4-ß-glucanase activity of C. formosanus were dete...
S Itakura, H Tanaka, A Enoki


Termite and decay resistance of particleboard composed of white cypress pine and radiata pine
1997 - IRG/WP 97-10200
Phenol-formaldehyde bonded particleboard was manufactured from blends of non-durable radiate pine (P. radiate) and heartwood of the naturally durable species, white cypress pine (C. glaucophylla). Board specimens were subjected to bioassays using two termite species, M. darwiniensis and C. acinaciformis, and the basidiomycete fungi, C. puteana and P. ostreatus, and the durability of specimens was ...
P D Evans, J W Creffield, J S G Conroy, S C Barry


Use of a stainless steel mesh to exclude formosan subterranean termites
1997 - IRG/WP 97-10199
Physical barriers are gaining in popularity world-wide as methods of preventing subterranean termite penetration and attack on structures. Sized particle barriers of crushed basalt or granite are approved for use in building construction in Hawaii and Australia. TERMI-MESH, a marine grade 316 steel mesh, was recently developed in Australia and is approved there, and now in Hawaii, for use as a ter...
J K Grace, J R Yates III, C H M Tome, R J Oshiro


Control of termite attack using a trapping method and acoustic emission (AE) monitoring a case study at an electric power plant
1997 - IRG/WP 97-10224
To prevent subterranean termites (Coptotermes formosanus Shiraki and Reticulitermes speratus Kolbe) from invading the buildings of an electric power plant and to control their attack, artificial traps were buried around the buildings. The attack of the termites in and around the traps was monitored by detecting acoustic emissions (AE) generated by the feeding behavior of the workers. The cylindric...
Y Fujii, Y Imamura, E Iwatsubo, S Yamamoto


Laboratory evaluation of JB-TB003 as potential bait toxicant against the subterranean termite, Coptotermes acinaciformis in Australia. subterranean termite, Coptotermes acinaciformis in Australia
1997 - IRG/WP 97-10214
In this laboratory evaluation, Coptotermes acinaciformis actively attacked in the first week of testing Pinus radiata wood blocks (50 x 25 x 15 mm3) treated with concentrations of JB-TB003 (i.e. 25, 50, 100, 200 and 400 ppm); the blocks with highest concentration were the most attractive. Results were similar whether blocks were leached or unleached. The earliest mortality occurred in the 400 ppm ...
B M Ahmed, J R J French, A R Valcke, P Blunt


Effects of steaming heat treatment of wood on the stimulation of termite feeding
1997 - IRG/WP 97-10212
At the 26th IRG conference, we reported that steamed Japanese larch heartwood samples were suffered a serious attack by subterranean termite, Coptotermes formosanus both in choice and no-choice feeding tests. This is possibly caused by the yield of termites stimulants in the wood samples resulting from the steaming process. Since the steaming heat treatment has often been applied to other several ...
S Doi, Y Kurimoto, M Takahashi, T Yoshimura


Termite physical barriers: update on retrofitting Granitgard™ around 'mock-up' buildings after five years
1997 - IRG/WP 97-10226
This field experiment was installed five years ago (March 1992) to evaluate the effectiveness of graded crushed granite stone, commercially marketed under the name Granitgard™, as a physical barrier when retrofitted around 'mock-up' buildings. The field site is located at Walpeup in the semi-arid mallee region of north-west Victoria (360 km from Melbourne), and there are eight ...
J R J French, B M Ahmed


International collaborative laboratory comparison of two wood preservatives against subterranean termites: Third update and first report
1996 - IRG/WP 96-10174
At the 24th annual meeting of IRG in Orlando, USA, in May 1993 an international subterranean termite laboratory bioassay to compare the various preferred termite protocols used by IRG termitologists was initiated. The author was nominated to co-ordinate this comparative laboratory evaluation of two wood preservatives, copper-chrome-arsenic (CCA) and copper naphthenate (Cu-Na) against the subterran...
J R J French


Previous Page | Next Page