Lab-scale termite damage synthesis using least squares generative adversarial networks
2020 - IRG/WP 20-20674
This manuscript investigated the feasibility of least squares generative adversarial networks (LSGAN) to generate synthetic images of lab-scale termite damage based on AWPA E1 standard, to push machine-learning forward into wood science field and to ameliorate the lack of a termite damage dataset. We leveraged LSGAN to learn the distribution of 203 uniquely termite damaged samples from previous ex...
D J V Lopes


Estimation of residual compressive strength on cross laminated timber with biodeterioration damage
2021 - IRG/WP 21-40918
CLT is susceptible to biodeterioration such as fungal decay and termite attack during long-term use for buildings. It is necessary to know the residual strength performance of biodegraded CLT for estimating future performance and aging of CLT. In this study, compression tests of CLT damaged by brown rot fungi and termites were conducted to clarify the relationship between residual strength and mas...
R Inoue, T Mori, K Kambara, W Ohmura


Comparative response of Reticulitermes flavipes and Coptotermes formosanus to borate soil treatments
1991 - IRG/WP 1486
Eastern (Reticulitermes flavipes [Kollarl]) and Formosan (Coptotermes formosanus Shiraki) subterranean termite workers (Isoptera: Rhinotermitidae) were exposed to borate-treated sand in an indirect exposure tunneling assay in the laboratory. In the ten day assay period, both termite species readily penetrated sand containing 5000, 10000, or 15000 ppm (wt. of compound / wt. of sand) disodium octabo...
J K Grace


Problems caused by termites in buildings in the State of Sao Paulo
1976 - IRG/WP 150
Termites are the main insects attacking buildings in the State of Sao Paulo - Brazil. Their attack occurs in wood and wooden materials as well as paper, textile, leather and so on....
M S Cavalcante


An evaluation method for less termite attack execution on thermal insulation for fundation walls
2002 - IRG/WP 02-20245
According to the results by the real scale Japanese building tests, the termite installation was observed at very little spaces between foundation and insulation. The termite penetration spaces between foundation and insulation on foundation systems in Japanese wooden houses were checked by the way of streaming speed of colored water. Because of difficulty for its execution, the parts of outside a...
K Suzuki, Y Tanaka


Phoracantha semipunctata Fab. dans le sud-ouest Espagnol: Lutte et dommages
1985 - IRG/WP 1250
L G Tirado


Trend in entomology of wood in use and in storage in Nigeria
1978 - IRG/WP 180
The current and potential impact of biotic agents of wood deterioration in Nigeria is reviewed, with emphasis on the insects and marine borers, their recognition and mode of damage. Some essential areas have no doubt been neglected and these are highlighted, while future lines of approach are outlined....
M O Akanbi


Physical barriers and bait toxicants: The Romeo and Juliet of future termite control
1991 - IRG/WP 1503
Soil chemical barriers are considered by some to be the most important technique for protecting buildings against subterranean termites in Australia (and elsewhere), providing a barrier against termite penetration. However, there is no such thing as a barrier that is 100 per cent +protective. And given the worldwide problems of using organochlorine termiticides, public awareness of chemical pollut...
J R J French


Report and recommendations of the National Termite Workshop held in Melbourne on the 17 April 2002.
2003 - IRG/WP 03-10478
There are two parts to this Report. Part One summaries the outcomes of an industry workshop organised to better scope the subterranean termite problem, identify knowledge gaps including R&D gaps and identifying strategies including cost-effective co-ordination mechanisms for addressing the issue. Part Two is a brief review of the current state of knowledge on subterranean termites of economic ...
B M Ahmed, J R J French


Trials on the field control of the Formosan subterranean termite with Amdro® bait
1982 - IRG/WP 1163
Amdro® - treated paper towels were introduced into two field colonies of the Formosan subterranean termite in Hawaii. At the concentration of 180 ppm, the toxicant bait was ineffective one month after the introduction. At higher concentrations (> 6,400 ppm), the baits were eaten initially; however, one week after introduction, termites avoided or covered the baits. The 15,000 ppm baits supress...
N-Y Su, M Tamashiro, J R Yates III


Termite resistance of pine wood treated with chromated copper arsenates
1997 - IRG/WP 97-30128
Two four-week, no-choice laboratory tests were performed with CCA-treated southern yellow pine and radiata pine against Formosan subterranean termites, Coptotermes formosanus. CCA retentions as low as 0.05 kg/m3 (0.03 pcf) provided protection from all but light termite attack (rating of 9 on a 10-point visual scale). Similar and consistent light attack on wafers containing retentions as high as 6....
J K Grace


Termite trail-following substances in Houttuynia cordata
2001 - IRG/WP 01-10409
Termite trail-following active compounds in the plant, Houttuynia cordata Thunb., were studied by a combination of chemical analyses and bioassay using Coptotermes formosanus Shiraki as a test termite. We have found that termites were attracted to methanol extracts from H. cordata. The n-hexane(Hex) extracts, that showed a trail-following activity, were fractionated by a silica-gel column chromato...
W Ohmura, K Yamamoto, M Saegusa, T Ohira, A Kato


Evidence supporting the use of termite baiting systems for long-term structural protection
2000 - IRG/WP 00-10377
The efficacy of the Sentricon Colony Elimination System containing Recruit II termite bait (0.5% hexaflumuron) in controlling active subterranean termite infestations has been demonstrated in numerous studies. This baiting system and other termite baiting systems are now widely used, and generally accepted, tools for remedial termite control in North America, Hawaii, and other parts of the world. ...
J K Grace, N-Y Su


Physical and biological properties of albizzia waferboards modified with cross-linking agents
1995 - IRG/WP 95-40043
Chemically-modified low-density waferboards with cross-linking agents were produced using a fast-growing species of hardwood albizzia (Paraserienthes falcata Becker) as a raw materials and isocyanate resin as a glue adhesive. For the chemical modification, the vapor-phase formalization of the boards and the pad-dry-cure treatment of wafers with cross-linking agents were employed. The vapor-phase f...
S Yusuf, Y Imamura, M Takahashi, K Minato


Laboratory evaluation of chemicals as termiticides
1986 - IRG/WP 1293
Laboratory procedures are described for screening chemicals against subterranean termites. Fast-acting compounds with persistent termiticidal activity are identified in tests using a soil substrate, and slower-acting bait toxicants are evaluated in a series of tests using cellulose substrates....
S C Jones


Biological control of the Formosan subterranean termite Coptotermes formosanus Shiraki
1971 - IRG/WP 100
M Tamashiro, J K Fujii, P Lai, T E Richardson


Conservation of wooden cultural property
1994 - IRG/WP 94-30038
A survey of the conservation of wooden archtitectual monuments, art objects and archaeological finds is presented. Each of the three areas has typical conservation problems which reqire the use of selected wood preservatives and consolidation agents. Furthermore specific protection and consolidation methods are necessary. A precise damage diagnosis with non-destructive testing methods is the first...
A Unger, W Unger


Über Wespen als Holzverderber - Schäden, Ursachen, Bekämpfung
1978 - IRG/WP 189
Observations and a number of actual cases over recent years show that wasps have been associated more frequently with damage to wood. The nature of such damage and the agents involved are as follows: 1. Decay following infestation by Woodwasps (Siricidae). 2. Punctate marks caused by superficial gnawing and also boring into wood by larvae of the Dock sawfly (Tenthredinidae). 3. Damage due to super...
S Cymorek


Response of the Formosan Subterranean Termite (Coptotermes formosanus) to Cellulose Insulation Treated with Boric Acid in Choice and No-Choice Tests.
2004 - IRG/WP 04-10532
The tunneling ability of the Formosan subterranean termite Coptotermes formosanus Shiraki through a cellulose insulation material containing11.1% boric acid was tested in choice and no-choice bioassays. We examined tunneling behavior and mortality of termites exposed to treated and untreated insulation material in miniature simulated wall voids. In a choice test termites tunneled through untreat...
M E Mankowski, J K Grace


Termite and decay protection - A superficial barrier field test
1983 - IRG/WP 3257
Samples of Pinus radiata were given a superficial barrier treatment and installed in the ground at two sites for five years to observe termite and fungal attack. The three best treatments of the series were Denso petroleum tape, Koppers hot dip tar enamel, and Arquad 2C/75 alkyl ammonium compound. As new fungicides and insecticides become available they are being added to the test using the same s...
R S Johnstone, W D Gardner


A method for screening termite baits using Coptotermes lacteus mounds
1984 - IRG/WP 1237
A method with several variations designed to rapidly screen potential bait substrates using Coptotermes lacteus mounds is described. The equipment used in this method is relatively inexpensive, readily prepared in the laboratory, and easily installed into active mounds in the field. Bait substrates are in continuous contact with a 'high termite hazard', and may be monitored with ...
J R J French, P J Robinson


What can DNA fingerprinting, aggression tests and morphometry contribute to the identification of colonies of the Formosan subterranean termite
2000 - IRG/WP 00-10371
Multilocus DNA fingerprinting, aggression tests and morphometry were compared to evaluate their potential for the identification of colonies of the Formosan subterranean termite, Coptotermes formosanus (Isoptera: Rhinotermitidae) in Hawaii. DNA fingerprinting separates the termites from all studied collection sites. Since the genetic similarity between termites from different collection sites lies...
C Husseneder, J K Grace


An investigation concerning Camponotus spp. distribution and damage in buildings in Sweden
1985 - IRG/WP 1248
This is a report of an investigation by a Swedish insurance company on the occurrences of damage by Carpenter ants during 1974 to 1981. The distribution of damage in walls, roofs and floors of both permanent homes and summer-houses has been assessed. It is concluded that the increased frequency of attack is becoming economically serious....
V Butovitsch, K-J Hedqvist, C Tornberg


Preliminary attempts towards the development of a small scale termite rearing chamber. Progress report
1983 - IRG/WP 1203
The results suggest that there is no evidence that the volume of the rearing chamber plays a part in the settlement of a colony. These rearing chambers present a factor of productivity (final enumeration)/(initial enumeration) of roughly 2 after one year. 90% of the colony survived. This method of breeding can be considered as feasible and cheap....
M Argoud, J C Palla, R Sternalsky


Sequential exposure of borate treated Douglas-fir to multiple Formosan subterranean termite colonies in a 40-week field test
1993 - IRG/WP 93-10006
Douglas-fir boards (ca. 74.5 g) pressure-treated with disodium octaborate tetrahydrate (DOT) retentions of 0 (controls), 0.88, 1.23, 1.60, or 2.10% (weight/weight) DOT were sequentially exposed to four active field colonies of Formosan subterranean termites, Coptotermes formosanus Shiraki (Isoptera: Rhinotermitidae), in an above-ground field test. Samples were placed in contact with each colony fo...
J K Grace, R T Yamamoto


Previous Page | Next Page