Your search resulted in 90 documents. Displaying 25 entries per page.
Utilization of curcumin for detection of presence of boron in wood
1982 - IRG/WP 3191
It has been shown that curcumin is not a reliable reagent for detecting boron in wood that has been attacked by fungi...
M-L Edlund
Detection of feeding behaviour of termites using AE monitoring
1991 - IRG/WP 1514
Using acoustic emission (AE) monitoring, the feeding activity of the termite inhabiting a wood specimen was investigated. The amplitude and the rate of AE from the specimen of Coptotermes formosanus Shiraki was larger than that of Reticulitermes speratus Kolbe. The AE event rate was higher in the specimen with soldiers than without soldiers. The AE event rate decreased according to the resistance ...
Y Imamura, M Tokoro, M Owada, Y Fujii, M Noguchi
Electron microscopic detection and chemical analysis of three-lamellar structures in wood-destroying fungi
1984 - IRG/WP 1240
In the course of transmission electron microscopical investigations of pine wood decay by various brown- and white-rot fungi extracellular three-lamellar structures (TLS) formed by the fungi were found in specimens stained with ruthenium red. These structures occured in the lumen of the wood cell surrounding the hypha at the outermost layer of the fungal cell wall. In the course of the investigati...
R Foisner, K Messner, H Stachelberger, M Röhr
Introduction to a field demonstration of various instruments and methods for the detection of defects in poles
1984 - IRG/WP 2228
H Friis-Hansen
Detection of semi-quantitative and qualitative enzymatic activities of blue-stain fungi
2000 - IRG/WP 00-10347
Blue-stain, produced in forests, continues to be a problem in countries of moderate climate. In forestry, in certain geographical areas of Spain, it has been observed that anti-sapstain products have not always been efficient, as their fungicidal effectiveness varies on occasion, depending on the species of wood and microbiota that exist in the region. It is not always easy to identify the species...
M T De Troya, F Llinares, D Muñoz-Mingarro, M J Pozuelo, N Acero, C Rodríguez-Borrajo, A M Navarrete
Detection of defects in standing poles by X-ray techniques
1980 - IRG/WP 2132
The application of X-ray techniques to wood pole inspection procedures has been evaluated. Internal defects were accurately identified using X-ray inspection methods. These methods and their possible influence on the safety and economic aspects of wood pale utilization are discussed....
W D Gardner, R S Johnstone, W Pitt
Non-destructive testing for the detection of defects in poles (letter to members of Sub-group 5 of WG II)
1982 - IRG/WP 2171
IRG Secretariat
Detection of brown rot decay in wood by ion mobility spectrometry
1991 - IRG/WP 2377
A test method for the detection of brown rot decay in wood is described and involves a two-step procedure: thermal release of vapours from wood samples followed by analysis using Ion Mobility Spectrometry (IMS), with results being obtained in 5-10 seconds. The advantages, limitations as well as the detection limit of the technique are presented....
A H Lawrence, T Nilsson
Fungal degradation of wood treated with metal-based preservatives. Part 2: Redox states of chromium
1996 - IRG/WP 96-10164
Concerns have arisen about the leaching of heavy metals from wood treated with metal-based preservatives, such as chromated copper arsenate (CCA). Of particular concern is the toxic redox state of chromium and arsenic in aging and decayed CCA-treated wood. Generally, hexavalent chromium is more toxic than trivalent chromium and trivalent arsenic is more toxic than pentavalent arsenic. The desired ...
B Illman, S Bajt, T L Highley
The Pilodyn instrument as a non-destructive tester of the shock resistance of wood
1978 - IRG/WP 2107
A new non-destructive shock resistance tester, the PILODYN, has been developed. The instrument measures the fracture surface area created by a constant amount of energy. It operates by shooting a blunt pin into wood by an exact amount of energy. The penetration depth is read on a scale. A wide field of application is open to a non-destructive shock resistance tester such as: 1) assessment of the r...
P Hoffmeyer
Detection of trace organics by ion mobility spectrometry
1990 - IRG/WP 3635
Ion Mobility Spectrometry (IMS) is a time of flight analytical technique that is suited to detect chemicals in the low parts per billion range. Some of the advantages of IMS are: operation at atmospheric pressure, fast response time (0.1-10 sec), and the ability to characterize individual chemical species in complex matrices without any prior sample preparation. In this paper, the utility of IMS i...
A H Lawrence
A bibliography of organic solvent-based wood preservatives
1973 - IRG/WP 322
H Alliot
Detection of incipient brown rot decay in wood by fourier transform infrared spectrometry
1987 - IRG/WP 2275
Fourier transform infrared spectrometry was evaluated as a possible method for detecting different levels of brown-rot decay in pine sapwood. By using first derivative spectra and regression analysis, an equation based on 4 absorption peaks, normalized with an internal standard peak, was developed. The correlation between weight loss and absorption was highly significant indicating that this is a ...
D D Nicholas, T Schultz
Methods of assessing decay in poles in service with the Pilodyn wood tester
1978 - IRG/WP 2107 A
H Friis-Hansen
CCA fixation experiments. Part 2
1989 - IRG/WP 3505
CCA fixation in wood was measured by both squeezing solution from treated wood that had not been dried and analyzing the solution for copper, chromium and arsenic, as well as using a chromotropic acid test to detect the presence of chromium VI. Both methods provide useful information on the CCA fixation process and illustrate that chromium VI disappears as CCA becomes fixed within wood....
W S McNamara
Spot-tests for TnBTO and AAC preservatives
1984 - IRG/WP 3279
Nineteen indicator systems were examined as potential alternative spot-tests for preservative penetration in TnBTO- (bis-tributyltin oxide) or AAC- (alkyl ammonium compound) treated wood. Results indicated phenylfluorone as an acceptable alternative to pyrocatechol violet for assessment of TnBTO, and cobaltous thiocyanate or a bromocresol green/quinine sulphate mixture as alternatives to bromophen...
D V Plackett
Electronic noses for detection of rot in wood
1996 - IRG/WP 96-20098
In an ongoing project an electronic nose is being studied and developed for detection of volatile organic compounds (VOC) emitted from wood colonised and decayed by fungi. The electronic nose consists of an array of gas sensors with different selectivity patterns for different groups of volatile organic compounds (VOC). The use of pattern recognition routines implemented by artificial neural netwo...
K Nilsson
The use of the Pilodyn for detecting soft-rot decay in CCA treated eucalypt poles
1986 - IRG/WP 2251
A 6 Joule Pilodyn unit with 2.5 mm diameter pin was used to inspect CCA treated eucalypt poles, suspected of suffering groundline soft-rot decay. Pole plugs were removed at the inspection region and the amount of soft-rot decay present determined microscopically. High correlation (R² = 0.73) was obtained between the amount of soft-rot and Pilodyn pin penetration. The Pilodyn is recommended as a u...
L E Leightley, G A Willoughby
Feasibility of AE (Acoustic Emission) monitoring for the detection of the activities of wood-destroying insects
1992 - IRG/WP 92-2416
The feasibility of acoustic emission (AE) as a nondestructive testing method for the detection of the wood destroying insects was investigated. AEs were detected from the wood specimens under feeding attack of sugi bark borers or powder-post beetles. However, the feasible monitoring area of an AE sensor is influenced by the attenuation of AE amplitude, so that this could be a problem in the practi...
Y Fujii, Y Imamura, E Shibata, M Noguchi
Detection of Acoustic Emission (AE) generated by termite attack in a wooden house
1999 - IRG/WP 99-20166
Recently, considerable attention has been paid to methods for termite control, which involves few or no chemicals. To reduce the amount of termiticide needed, it is necessary to detect termite attack in wood as early as possible. The feasibility of acoustic emission (AE) monitoring for the nondestructive detection of termite attack has been discussed previously. In this study, we propose some tech...
Y Fujii, Y Yanase, T Yoshimura, Y Imamura, S Okumura, M Kozaki
Examination of the Pilodyn as a non-destructive test method for detecting decay in CCA treated eucalypt poles
1982 - IRG/WP 2177
Below groundline condition of 274 CCA treated eucalypt poles comprising 13 different species was examined using 6 and 12 Joule Pilodyn units with 2 and 2.5 mm diameter pins. The data obtained was used to calculate regressions of density on pin penetration. A decrease in density was accompanied by an increase in pin penetration. The best correlation was found using the 6 Joule, 60 x 2.5 mm² diamet...
L E Leightley
A bibliography of organic solvent-based wood preservatives
1973 - IRG/WP 313 E
H Alliot
Introduction to keynote: Perspective in urban termite biology and management in Southeast Asia
2012 - IRG/WP 12-10786
This keynote lecture will provide a perspective on the pest status of termites in Southeast Asia, the damages they cause to the urban structures, important biological and behavioural characteristics, detection methods and the various management strategies available....
Chow-Yang Lee
Detection of termite attack in wood using AE monitoring
1990 - IRG/WP 2355
An acoustic emission (AE) monitoring method for detecting termite activity in wood was applied to lumber of 3 by 3 cm to 10 by 10 cm square, 1 m long. Furthermore, the propagation of AEs due to the feeding activities of termites in the specimens and the locations of AE sources were analyzed. Also discussed was the feasibility of the method applied to posts out in the field of subterranean termites...
Y Fujii, M Owada, M Noguchi, Y Imamura, M Tokoro
A Long-term Observation of Termite Activity in The Nest by Continuous Acoustic Emission (AE) Monitoring
2003 - IRG/WP 03-20280
In order to evaluate the influence of temperature on the termite activity, acoustic emission (AE) monitoring was applied to two nests of Coptotermes formosanus SHIRAKI; a nest in the stem of a standing tree and a nest in the underground of a wooden house, respectively. Temperature change in and around the nests were continuously measured for about one year using thermocouples at four points; the c...
Y Yanase, Y Fujii, S Okumura, T Yoshimura, Y Imamura