Practical considerations of the Formosan subterranean termite in Louisiana: A 50-year-old problem
2000 - IRG/WP 00-10330
In an eleven-year censusing (1989 through 1999) in the French Quarter of New Orleans and surrounding areas, Coptotermes formosanus alate numbers were found to be increasing dramatically in all years but one. Moreover, in parks and neighborhoods in New Orleans and Lake Charles, LA, as well as in Sam Houston Jones State Park near Lake Charles surveyed in 1998, alarmingly high numbers of this exotic ...
G Henderson


Formosan Subterranean Termite Resistance to Heat Treatment of Scots Pine and Norway Spruce
2003 - IRG/WP 03-40264
New challenges to the durability of wood building materials have arisen in the U.S. The Formosan subterranean termite (Coptotermes formosanus Shiraki) now infests sizable portions of the U.S. south and their range is extending. Heat treatments offer a unique opportunity for wood-based composites because many of the process techniques already employ various thermal applications and could be easil...
W R Smith, A O Rapp, C R Welzbacher, J E Winandy


Preliminary indications of the natural durability of Spruce bark board
1999 - IRG/WP 99-10312
A board material made from pressed bark, with no added adhesive, has been developed by Forintek's composites group and tested for durability by Forintek's treated-wood group and the University of Hawaii. This material was also manufactured with veneers in a one-step process. Since one role of bark on the tree is protection against pests and diseases, barkboard was expected to hav...
P I Morris, J K Grace, G E Troughton


The response of the Formosan subterranean termite (Coptotermes formosanus Shiraki) to different boron compounds
2007 - IRG/WP 07-10609
Although boric acid and other boron compounds have been used since the 1800s as insecticides, their mode of action is not well understood. Borate salts, in particular sodium and zinc formulations, are effective wood preservatives and are used extensively in Hawai’i to protect building materials from both drywood (Kalotermitidae) and subterranean (Rhinotermitidae) termites. The Formosan subterra...
M C Gentz, J K Grace


Foraging Behavior of the Formosan Subterranean Termite (Isoptera: Rhinotermitidae) in Response
2007 - IRG/WP 07-10605
Foragers of the Formosan subterranean termite, Coptotermes formosanus Shiraki, were allowed to tunnel in two dimensional, sand filled arenas containing Douglas-fir (Pseudotsuga menziesii [Mirb.] Franco) wafers pressure treated with disodium octaborate tetrahydrate (DOT) to an average retention of 1.77 % BAE on one side of each arena, and untreated wafers of Douglas-fir on the other side. Arenas w...
C E Campora, J K Grace


Problems caused by termites in buildings in the State of Sao Paulo
1976 - IRG/WP 150
Termites are the main insects attacking buildings in the State of Sao Paulo - Brazil. Their attack occurs in wood and wooden materials as well as paper, textile, leather and so on....
M S Cavalcante


Report and recommendations of the National Termite Workshop held in Melbourne on the 17 April 2002.
2003 - IRG/WP 03-10478
There are two parts to this Report. Part One summaries the outcomes of an industry workshop organised to better scope the subterranean termite problem, identify knowledge gaps including R&D gaps and identifying strategies including cost-effective co-ordination mechanisms for addressing the issue. Part Two is a brief review of the current state of knowledge on subterranean termites of economic ...
B M Ahmed, J R J French


Laboratory evaluation of chemicals as termiticides
1986 - IRG/WP 1293
Laboratory procedures are described for screening chemicals against subterranean termites. Fast-acting compounds with persistent termiticidal activity are identified in tests using a soil substrate, and slower-acting bait toxicants are evaluated in a series of tests using cellulose substrates....
S C Jones


Physical barriers and bait toxicants: The Romeo and Juliet of future termite control
1991 - IRG/WP 1503
Soil chemical barriers are considered by some to be the most important technique for protecting buildings against subterranean termites in Australia (and elsewhere), providing a barrier against termite penetration. However, there is no such thing as a barrier that is 100 per cent +protective. And given the worldwide problems of using organochlorine termiticides, public awareness of chemical pollut...
J R J French


Studies on the foraging of subterranean termites
2000 - IRG/WP 00-10345
To study the foraging galleries of subterranean termites in soil, early researchers painstakingly excavated underground tunneling system of these cryptic insects. Erhorn (1934) listed a report by Oahu Sugar Co., Ltd. in 1928 showing that runway of Coptotermes formosanus may extend up to 50 m long and 0.3 - 3 m deep. Ratcliffe & Greaves (1940) who excavated foraging galleries of Coptotermes lac...
N-Y Su


Development of a Granitgard® particulate termite barrier for use in tropical Australia
1997 - IRG/WP 97-10190
Granitgard® is superficially simple technology; graded crushed aggregate, sieved to a size range impenetrable to subterranean termites. However, behind this apparent simplicity lies a large research effort. In this paper we describe the laboratory development of a grading of Granitgard suitable for use against the wide range of termites which attack timber in northern Australia, above the Tropic ...
D M Ewart, E R Rawlinson, A D Tolsma, G C Irvin, P R Wiggins


Evaluating the Exterra Termite Interception and Baiting System in Australia
2003 - IRG/WP 03-20267
The Exterraä Termite Interception and Baiting System (Ensystex Inc., Fayetteville, NC) was evaluated in a field experiment near Townsville, Australia. Cellulose-acetate powder containing either 0.05% weight/weight (w/w) or 0.25% w/w chlorfluazuron (Requiemä) was tested for its efficacy in eradicating colonies of the mound-building subterranean termite Coptotermes acinaciformis (Froggatt). Thirte...
B C Peters, S Broadbent


A critical review of the AWPA standard method (M12-72) for laboratory evaluation to determine resistance to subterranean termites
1986 - IRG/WP 1298
The American Wood Preservers' Association standard (M12-72) for evaluation of candidate wood preservatives against subterranean termites is reviewed and suggestions for revision are made. The most serious flaws in the current test procedure involve a failure to recognize inter- and intraspecific variation and a lack of quantification of test results....
J P La Fage, M Jones


Baiting techniques for subterranean termite control
1983 - IRG/WP 1205
The use of artificial baits, with and without toxins, have proved effective in attracting large numbers of non-mound and mound building subterranean termites in both urban and rural areas. An outline is presented of a termite baiting program which emphasises concurrent laboratory and field investigations on termite ecology, behaviour and physiology...
J R J French, J P Robinson


Tunneling ability of subterranean termites through termiticide-treated soil
1988 - IRG/WP 1375
A test apparatus was designed to facilitate accurate measurement of termite penetration into termiticide-treated soil; three termiticides at 500 ppm were evaluated. Coptotermes formosanus Shiraki workers tunneled significantly farther into chlordane-treated soil than did Reticulitermes flavipes (Kollar). Both species only slightly penetrated chlorpyrifos-treated soil. Neither species penetrated so...
S C Jones


Envelope treatment to protect softwood timbers from damage by subterranean termites
2003 - IRG/WP 03-30313
Two aboveground field trials were conducted in Australia to determine the effectiveness of envelope treatments of deltamethrin and permethrin for the protection of softwood framing timbers against termite damage. Radiata pine Pinus radiata D.Don and slash pine Pinus elliottii Englem., were treated with Tanalithä T (a novel solvent) to achieve 5-mm-depth envelopes. Details of a field trial against...
B C Peters, J W Creffield


Preliminary evaluation of borate baits and dusts for eastern subterranean termite control
1990 - IRG/WP 1433
Borates are of potential use in the development of baiting systems for subterranean termite control. In the 15-day laboratory assays reported here, the oral toxicity of disodium octaborate tetrahydrate to Reticulitermes flavipes (Kollar) was evaluated under choice and no-choice conditions. These assays suggest a range of 2500 to 5000 ppm to be applicable in developing baits, and that concentration...
J K Grace, A Abdallay, J M Sisson


Studies on the infesting behaviour of the Formosan termite, Coptotermes formosanus Shiraki and its physical control
1983 - IRG/WP 1174
An outline of termite damage to buildings in Japanese National Railways, wood-infesting behavior, attacked traces in PVC-sheathed cables by termites, detection method of termites and the physical control method of the Formosan termite are given in the present paper....
K Yamano


A method to evaluate the effeetiveness of bait application using a transferred nest of Coptotermes formosanus Shiraki (Isoptera: Rhinotermitidae)
1999 - IRG/WP 99-20161
Although a survey of monitoring stations can tell us the decline of termite activity after application of baits, it seems questionable to conclude an eradication of a Whole colony of subterranean termites if the termites move out their foraging territory. Only reliable method to ensure the success of bait application is to determine the absence of living termites in their nest in accordance with a...
K Tsunoda, T Yoshimura, H Matsuoka, Y Hikawa


Eastern subterranean termite responses to three soil pesticides
1990 - IRG/WP 1432
In laboratory assays simulating field conditions, tunneling and mortality of Reticulitermes flavipes (Kollar) workers were evaluated in sand treated with aqueous solutions of formulated chlorpyrifos, isofenphos, and disodium octaborate tetrahydrate. Chlopyrifos and isofenphos were evaluated at concentrations of 500 and 1000 ppm (weight of active ingredient / weight of sand), and disodium octaborat...
J K Grace


Laboratory evaluation of fipronil (a phenyl pyrazole) as a candidate termiticide in the protection of wood against the subterranean termite, Coptotermes acinaciformis (Froggatt) Rhinotermitidae
1997 - IRG/WP 97-10225
In this laboratory evaluation, radiata pine wood blocks (50 x 25 x 15 mm3) were impregnated with fipronil (a phenyl pyrazole) at various concentrations (0, 5, 10, 20, 40, 80, 100 and 200 ppm). Half the treated blocks underwent a leaching schedule for 5 days, while the remainder were unleached after treatment. Five replicates per treatment regime were presented to the test termite, Coptotermes acin...
B M Ahmed, J R J French, P Kwint, G Webb


Bioassays of extracts from scaly ash (Ganophyllum falcatum B1) against the subterranean termite Coptotermes acinaciformis (Froggatt)
1983 - IRG/WP 1206
Scaly ash, Ganophyllum falcatum B1. wood shavings were extracted by methanol, and fractionated with ethyl acetate, diethyl ether and water, and the anti-termitic properties of these materials bioassayed against the subterranean termite Coptotermes acinaciformis (Froggatt). Laboratory techniques were developed to overcome the problem of limited extractive materials. The results of the various bioas...
J R J French, J P Robinson, J W Creffield


The effectiveness of deltamethrin against subterranean termites (final report)
1993 - IRG/WP 93-30011
Two series of block tests of Pinus sp were treated by dipping them for 1 (one) minute in a solution with 0.015 (w/w) and 0.05 (w/w) of deltamethrin, respectively. In both cases, an average retention of 47 kg/m³ (0.32 l/m) was reached. One part of the block tests remained under laboratory conditions during 9 months, and the other was stored during equal period of time in a theater basement submitt...
P A Zanotto


International comparison of three field methods for assessing the in-ground termite resistance of materials - highlights after two years
1999 - IRG/WP 99-20157
First-year results of a comparative study, evaluating the in-ground termite resistance of a range of materials, including CCA and ACQ-treated timbers, using the below-ground exposure, ground contact and graveyard methods against diverse termite faunas were provided in IRG/WP/98-20132. Further annual inspections have confirmed early trends and identified notable differences between sites and method...
M Lenz, J W Creffield, A F Preston, B M Kard, C Vongkaluang, Y Sornnuwat


Laboratory evaluation of borate formulations as wood preservatves to control the subterranean termite coptotermes acinaciformis (isoptera: Rhinotermitidae) in Australia
2001 - IRG/WP 01-30266
The termiticidal efficacy of Borocol (sodium octaborate tetrahydrate), boric acid, bore-ester-7 and tri- methyl borate was evaluated in laboratory bioassays against Coptotermes acinaciformis (Froggatt). Seasoned sapwood blocks of Pinus radiata D. Don, and Eucalyptus regnans (F. Muell) were impregnated with the various borate compounds. There were marked differences in mass loss and mortality rate ...
B M Ahmed, J R J French, P Vinden


Previous Page | Next Page