Your search resulted in 76 documents. Displaying 25 entries per page.
Japanese Classification of Wooden Building Members for ISO Use Classes according to the Building Code in Japan.
2006 - IRG/WP 06-20337
Because of the international approve of use class system for the biological degradation of wood by ISO/DIS 21887 and ISO/DIS 21892, Japanese committee of ISO/TC165/SC1 asked to the JWPA for classify the wooden commodities by use class of these draft ISO. The JWPA was prepared a draft use class model in Japan. Japanese building code systems are described and Japanese draft use class system is also ...
K Suzuki
Work programme of CEN/TC 38 (April 1999) and European publications
1999 - IRG/WP 99-20165
Scope of the CEN/TC38: Standardization of the characteristics of natural or conferred durability of wood and its derived materials against biological agents, including the characteristics of protection products and associated processes to obtain this durability. This applies in particular to: - the identification of hazard classes-, - the test methods (wood preservatives and treated wood and wood ...
R Hüe
Second international symposium on wood preservation "The challenge safety-environment" 8-9 February 1993, Cannes-Mandelieu, France
1993 - IRG/WP 93-50001
Contains the following 34 Documents (IRG/WP 93-50001/1 - IRG/WP 93-50001/34) and 4 abstracts:
A methodology for the life-cycle assessment of treated timber products (IRG/WP 93-50001/1)
Initial results and observations of a model system to assess the efficacy and environmetal impact of preservative treated wood (IRG/WP 93-50001/2)
Borates as wood preservatives - an environmental, health and safe...
Anonymous
Towards harmonisation of regional approaches for an International Standard for the approval of wood preservatives
1997 - IRG/WP 97-20122
Recent proposals from the European Standards body (CEN) for an ISO Standard on wood preservatives has initiated debate on whether there is any prospect of an acceptable common approach among ISO member countries, to a harmonised framework of hazard classes, with agreed supporting biological tests, leading to a unified rationale for demonstrating compliance with minimum performance standards for sp...
A F Preston, A F Bravery
Quality of timber impregnated with preservatives of class AB
after three years in service
2002 - IRG/WP 02-20241
Quality of impregnated timber is most often expressed by penetration and retention of the preservative used. Relatively less information is available about the performance of the final product, e.g. decks, panels etc. regarding product’s surface checks, deformations and overall appearance. Together with the timber durability, the above mention features are of esthetical importance in the above g...
N Terziev
European standardization for wood preservation
1991 - IRG/WP 2365
Since the last IRG 21 conference in New-Zealand, there one meeting of the plenary committee and several meetings of working groups. The interprative documents prepared by CCE for expliciting the essential requirements of the CCE Directive on the construction products and specially: mechanical resistance and stability / hygiene, health and environment / safety in use
are waited to valid the progra...
Anonymous
Sawn timber of fir (Abies alba Mill.) - Treatability and usability for the Hazard Classes 3 and 4
1999 - IRG/WP 99-40147
Within a national research project, tests on the treatability on sawn timber of fir (Abies alba Mill.) in oscillation pressure, vacuum pressure and double-vacuum processes have been worked out with 95 trunks taken from 3 different altitude levels (up to a height of 590 metres, 600 to 990 metres and over 1000 metres) and from 4 different regions of Switzerland. As the treatability of round wood can...
E Graf, T Bör
Revised South African standards for wood preservation: Protocols for approval of wood preservatives
1995 - IRG/WP 95-20072
In 1994 the South African timber treatment industry completed its revision of the South African Bureau of Standards (SABS) Code of Practice for the preservative treatment of timber. These revisions were undertaken in parallel with changes to the SABS specifications for preservative treated timber. As a result of shortcomings in the previous wood preservative classification system which was based o...
D Conradie, P Turner, W E Conradie, A D Currie, I S J Burger
Summary report: Symposium "The challenge - Safety and Environment"
1990 - IRG/WP 3590
This summary, presented orally to the audience before the closure of the meeting, received on the principles a wide consensus. It has been written down to be submitted for presentation and discussion at the IRG/21st meeting in ROTORUA, 13-18 may 1990. It cantains summaries from Dr C R Coggins, chairman of Session I (PESTICIDES AND FORMULATIONS); Dr B Hegarty, chairman of Session II (TREATED WOOD);...
Anonymous
Proceedings from the wood preservation symposium "The Challenge - Safety and Environment" 19-20 February 1990, Cannes, France
1990 - IRG/WP 3600
Contains the List of Participants and the following 29 Documents (IRG/WP/3562-3590):
Canadian code of good practices - Recommendations for design and operation of wood preservation facilities. (IRG/WP/3582)
Current models used by the European health authorities to evaluate the vililization of active ingredients from treated wood used inside dwellings. (IRG/WP/3565)
Creosote and cancer. (IRG/WP/...
Anonymous
Environmental situations on wood preservation industries in Japan
1995 - IRG/WP 95-50040-21
Because of environmental civil oppinions, Ministry of Agriculture, Forestry and Fisheries in Japan, reviesed "the standards for sawn lumber" in 1994. For the possibilities of the use of preservatives out of CCA, by the using of the hazard levels, new products like ACQ, DDAC and emulsified zinc-naphthenate can be used in the standards. Since 1994, the permitable limit of the arsenic in the waste wa...
K Suzuki
Wood preservation requirements in Queensland, Australia
1983 - IRG/WP 3227
In Queensland the preservative treatment and utilization of timber must comply with the Timber Users' Protection Act. Preservative retention levels and penetration patterns must be complied with. Analytical zones are specified for removing samples for chemical analysis of preservative retention. The required retention levels have been expressed as percent weight of oven dry wood weight. T...
L E Leightley, M J Kennedy
Proceedings of the 3rd international wood preservation symposium "The Challenge - Safety and Environment" 6-7 February 1995, Cannes-Mandelieu, France
1995 - IRG/WP 95-50040
Contains the following 35 Documents (IRG/WP 95-50040/1 - IRG/WP 93-50040/35), conclusions (summaries of the sessions chairmen) and some poster abstracts:
Le pin: Matériau à contact alimentaire [Pine wood as a material for food contact] (IRG/WP 95-50040/1); The use of a physical field model to study the effects of remedially treated timber on the growth of perennial ryegrass (Lolium perenne) and...
Anonymous
Studies and experiences of occurrence and development of soft rot in salt-treated poles of pine (Pinus sylvestris) installed in Swedish transmission lines in the years 1940-1945
1977 - IRG/WP 277
The present work describes the result of microscopic examinations of some 2,000 borings extracted from 20 to 23-year-old salt-treated poles (Scots pine) from the southern and central parts of Sweden. The purpose was to map out the occurrence of soft rot in Sweden and its influence on the mechanical strength of the poles as well as to contribute to the development of new and more satisfactory metho...
H Friis-Hansen
European standardization for wood preservation. Progress report 91-92
1992 - IRG/WP 92-2398
Since the IRG 22 conference in Kyoto, CEN/TC 38 Plenary met twice in relation with several working group meetings. 5 upon 6 of the interpretative documents have been prepared by adhoc groups of the Standing Committee for Construction within the scope of the 89/106/EEC directive on Construction Products. The expected requirements attached to wood preservation are both requirements 1) and 3): 1) mec...
R Hüe
Categories in wood preservation hazard, risk, and use
1994 - IRG/WP 94-20048
In various countries hazard-, risk-, or use-categories have been established. The different terms seem to be only a sophisticated language problem, but they are rather a basic principle of the philosophy of wood preservation which is going to obtain importance with respect to the low reputation of chemical wood preservatives in an increasing number of countries. Whilst hazard signifies the fact th...
H Willeitner
Performance criteria for approving new wood preservatives for ground contact
1994 - IRG/WP 94-20021
Protocols for testing novel formulations prior to approval or registration as wood preservatives are being developed in a number of countries, e.g. Australia, New Zealand, USA. One aspect which must be addressed is the effectiveness in tests relative to that of currently approved formulations which would be acceptable to approving authorities. It is assumed that natural exposure testing is a prere...
M E Hedley
Evaluation of wood preservatives for Nordic wood preservation class AB
2002 - IRG/WP 02-30297
In the Nordic countries there are restrictions in the use of wood preservatives based on chromium and arsenic. For above ground use, class AB according to the Nordic system, only
copper based preservatives are allowed in Sweden. Thus several new preservatives, copper based or metal free are now used. They have been approved by the Nordic Wood Preservation Council after passing laboratory tests ag...
M-L Edlund, J Jermer
The risk assessment process. Point of view of a biocide manufacturer [Évaluation du risque. Point de vue d'un fabricant de biocide]
1990 - IRG/WP 3568
Risk assessment is an inherent part of our everyday lives. The risk assessment equation combines Hazards and Exposure. For the Wood Preservation Industry, the hazards may be characterised by the toxicity a the ecotoxicity of chemicals and the exposure by the identification of exposed people, of the exposure routes and exposure frequency. To quantify the exposure, good co-operation is required betw...
D Baur
Is Field Test Data from 20 x 20mm Stakes Reliable? Effects of Decay Hazard, Decay Type and Preservative Depletion Hazard
2006 - IRG/WP 06-20327
Effects of decay hazard, decay type and preservative depletion hazard on the performance of variously preservative treated 20 x 20 x 500 mm Radiata pine and Fagus sylvatica test stakes across 13 field test sites in New Zealand and Queensland Australia were determined.
Radiata pine treated with an ammoniacal copper quaternary preservative (ACQ) (1.56% m/m a.i.) and copper chrome arsenate (CCA) (...
R Wakeling
A New Decay Hazard Map for North America Using the Scheffer Index
2008 - IRG/WP 08-10672
Wood decay experts in the USA and Canada use the Scheffer Index for above-ground wood decay potential to decide among design and treatment options to ensure the durability of wood construction. This paper provides an updated North American decay hazard map and includes data on Central America. Index values calculated from recent climate data are higher than published values due to directional or c...
P I Morris, J Wang
Decay Hazard Classifications in China for Exterior Above-Ground Wood
2007 - IRG/WP 07-20357
A decay hazard map for exterior above-ground wood structures is presented based on Scheffer’s Climate Index, with the major purpose of promoting awareness for proper protection of wood structures in different locations in China. A very large area in the South, including southern Yunnan, most of Sichuan Province and Chongqing, and part of Hunan, Hubei, Anhui, Jiangxi, and Zhejiang, as well as all...
J Wang, X Wu, M Jiang, P I Morris
Emission Rates of Active Substances from Preserved Wood in Use Class 3
2008 - IRG/WP 08-50256
The evaluation of an active substance or a biocidal product under the Biocidal Products Directive (BPD) requires that an environmental risk assessment is carried out. The risk assessment for wood preservatives includes scenarios for preserved wood (e.g. cladding on a house), in which the
predicted environmental concentration (PEC) in soil is calculated, using an emission rate for the active subs...
E F Baines
Effect of different ASAs (alkenyl succinic anhydrides) on the treatment of biological protection of wood in use class 4
2008 - IRG/WP 08-40440
The alkenyl suscinic anhydrides (ASAs) used in this work are adducts resulting from the maleinization reaction of fatty acid alkyl esters. Various products with different alkyl groups were synthesized from rapeseed (Brassica napus) oil esters, rich in oleic acid. The liquids obtained showed a viscosity similar to that of vegetable oils and a brown color. When applied into wood, a thermal treatment...
C Vaca-Garcia, O Pignolet
Ensure Durable Wood-Frame Construction under the Climate and Biological Hazards in Shanghai
2009 - IRG/WP 09-20413
This paper provides technical background for developing durability-related provisions for the Shanghai wood-frame construction code. It summarizes the related climate, decay and termite hazards in this area as well as traditional durability solutions used for wood and wood hybrid constructions in China. The overall durability principles or philosophy used throughout this durability chapter are to ...
Jieying Wang, Chun Ni, Jiahua Zhang