Quantification of creosote and fluoride in remedially-treated poles
1997 - IRG/WP 97-40097
Three creosoted transmission poles were put into service in 1961 and they were subsequently remedially-treated with a proprietary fluoride remedial paste formulation in 1981. The poles were removed from service in 1996 and their ground-contact regions were analysed for creosote and fluoride contents. It was found that the poles were undecayed. Creosote retentions decreased down the profiles of the...
B P Hill


Extending the useful life of creosoted electricity distribution poles in service
1993 - IRG/WP 93-50001-16
Creosoted transmission poles have provided good service over many decades in a whole range of environments. The use of save biocides for secondary treatments has the potential to extend the life of such poles. These techniques, together with a full understanding of the modes of failure, make it possible to establish new strategies to further improve the environmental benefits of treated wooden pol...
D J Dickinson, B Calver


Some observations on causes of failure of preservative treated natural round transmission poles in Nigeria
1977 - IRG/WP 291
Treated natural round transmission poles in Nigeria have been discovered to be attacked underground as early as two years after planting. Termites and rot fungi attack the inner tissues and leave a pattern characteristic for the species of the pole. Tectona grandis, Nauclea diderrichii and Wide Pore pine, the major species for transmission poles in Nigeria show these attacks. A form of termite shi...
M A Odeyinde


Soft rot and bacterial decay in preservative treated eucalypt power transmission poles
1982 - IRG/WP 1155
Bacterial type decay was observed in CCA and PCP treated eucalypt power transmission poles. Detailed observations made with the SEM revealed bacterial colonisation and decay, especially in fibres. Plug samples taken from poles throughout Queensland were examined for preservative retention and presence of soft-rot decay. The severity of decay was different according to location, retention and speci...
L E Leightley


Proposal for further work on pretreatment decay
1988 - IRG/WP 1374
Pretreatment decay is a world wide problem sometimes ignored by pole producers. Words like "poles are not worse now than they were 50 years ago" or "we have always handled poles in this way without trouble" are weak defences. All other industries try to make their products better, so why not the impregnation industry? Or is the pole industry right? What do we know about the long term effect of pre...
M-L Edlund


A short note on fungal decay in K33-treated poles
1982 - IRG/WP 1169
Soft rot cavities and erosion of the lumen have been found in K33-treated Pinus sylvestris poles from the years 1956-66 by microscopic studies. Poor treatment quality has been proved for some of these poles. The microscopy showed an unusual pattern of attack, and pre-treatment decay is suspected but not yet proved. Sounding the poles and using the Pilodyn indicated decay, but poking did not. Quant...
H Friis-Hansen


A baiting technique to monitor the development and control of decay in transmission poles
1981 - IRG/WP 2149
P I Morris, D J Dickinson


Transmission poles with sub-standard retentions protected by Field Liners outperform standard poles in service
1997 - IRG/WP 97-40095
Eucalyptus cloeziana 12m transmission poles were treated with sub-standard creosote retentions of 80kg/m3 and Field Liners were fitted to the poles before they were placed in service at Umbumbulu, Kwazulu Natal. Poles treated with standard creosote retentions of 130kg/m3 but without Field Liners were also placed in service in the same area. Core samples were taken from both groups of poles after 1...
M R Behr, G D Shelver, A A W Baecker


Patterns of bacterial attack in preservative treated eucalypt power transmission poles
1984 - IRG/WP 1223
Patterns of bacterial decay have been examined using light and scanning electron microscopy. Two morphologically distinct patterns have been recognised in preservative treated eucalypt power transmission poles. Bacterial Decay I (BDI) involves the removal of the secondary wall layers initiating with erosion of the S3 layer from the cell lumen. As decay progresses the S2 layer and S1 layer are degr...
G A Willoughby, L E Leightley


Life cycle analysis of utility poles. A Swiss case study
1995 - IRG/WP 95-50040-05
Use of preservative-treated wood products faces increasing public and political pressure because of environmental concerns regarding the chemicals used to protect the wood. However, critics usually focus only on one single aspect of the whole life cycle of treated wood products, disregarding other environmental effects of timber utilization. To evaluate the ecological consequences of wooden utilit...
T Künniger, K Richter


Isolation and identification of bacteria from CCA-treated eucalypt power transmission poles
1987 - IRG/WP 1317
Bacteria have been isolated from CCA treated Eucalyptus maculata poles which possessed characteristic bacterial decay patterns. Cultures were isolated on a number of different media which had been inoculated with a splinter of degraded wood. Primary tests indicated that most isolates belonged to the genera Pseudomonas and Bacillus. The species Pseudomonas cepacia was most frequently isolated....
G A Willoughby, A C Hayward, L E Leightley


The evaluation of the occurrence of soft rot in creosoted wooden poles
1988 - IRG/WP 1368
The occurrence of soft rot decay in creosoted wooden poles for overhead power lines was investigated by collection of field samples, their subsequent microscopic examination and statistical analysis of the data collected. Examination of samples collected from 296 poles revealed that approximately 15% of the pole population studied (Eastern Electricity Board) showed the presence of soft rot decay. ...
A Wylde, D J Dickinson


Sampling variation in a copper chrome arsenic treated power transmission pole
1990 - IRG/WP 2351
The Queensland Forest Service routinely samples poles treated at all treatment plants throughout the State. Each treatment plant is issued with a Certificate of Registration and the accompanying documents list the different levels of preservative retention required for performance in various service conditions. The posted levels represent the.minimum permissible, and it is to these concentrations ...
J Norton


Soft rot studies on CCA treated eucalypt power transmission poles
1981 - IRG/WP 1132
Initial results found for sixty CCA treated eucalypt poles, from a soft-rot survey are discussed. Retentions of CCA within above and below ground pole samples were variable. The variation was attributed mostly to biodegradation and effect of soil environment, rather than leaching. Bacterial decay was found in many poles and was severe in some cases. Although found in the presence of soft-rot decay...
L E Leightley


The rate of losses of creosote from power transmission poles during storage
1998 - IRG/WP 98-50101-24
The purpose of this work was to study the rate of losses of creosote from power transmission poles and its consequences on the expected life of the poles stored for a long period in horizontal position. Apart from this main target of the study, the results could allow a rough estimate of the load of creosote substances on the soil especially when the poles are stored and this load accumulates over...
Z Vassou, A Satanakis, C Koutsikopoulus, J Petinarakis


Butt-end incising to improve penetration and retention of creosote in Eucalyptus saligna power transmission poles in Kenya. Preliminary results
2002 - IRG/WP 02-40249
Incising as a possible technique to improve penetration and retention of creosote in the butt end of Eucalyptus saligna power transmission poles in Kenya was investigated. Debarked, butt-end samples from whole poles were seasoned (15% MC), incised using four patterns of incisions, sealed at the top or small diameter end, and pressure treated with a mixture of creosote-furnace oil (60/40 mix) at a...
R Venkatasamy


Preliminary modelling of methylisothiocyanate movement through Douglas fir transmission poles
1988 - IRG/WP 3466
Methylisothiocyanate is a volatile solid that is the active ingredient of several registered and experimental wood fumigants. Information on the sorption and diffusion of this chemical in Douglas-fir heartwood and sapwood was used to develop a two-dimensional model of fumigant movement within a single horizontal cross-section of a transmission pole. The model indicated that dry wood (14% MC) stron...
A R Zahora, P E Humphrey, J J Morrell


Field Liners™ prevent creosote migration from transmission poles to soil during service
1996 - IRG/WP 96-40067
A full scale trial utilised 150 12m Eucalyptus grandis transmission poles treated with standard retentions of creosote according to SABS Method 457. One hundred poles had Field Liners™ applied while 50 did not. The 150 poles were used to complete an electricity transmission line in Southern KwaZulu-Natal. After 18 months service, incremental cores were taken from 15 cm below the ground lines of ...
M R Behr, G D Shelver, A A W Baecker


The use of spruce for transmission poles
1973 - IRG/WP 326
A series of preservative treatments with creosote using Lowry and Rueping schedules was undertaken. From these treatments the most suitable impregnation conditions for water stored Sitka spruce (Picea sitchensis) and Norway spruce (Picea abies) transmission poles were determined. Preservative distribution and permeability values for poles of both species were used to decide the optimum season and ...
J A Dunleavy, D J Balfe, J P Prendergast


Evaluation of a utility pole inspection procedure
1996 - IRG/WP 96-20084
Methods were developed and are currently being utilized to appraise residual strength of utility poles based on visual assessment of increment cores. Strength tests, mycological descriptions and anatomical analyses were performed on eight utility poles taken out of service and one new (never in service) pole. Samples were obtained from increment cores removed from 6 levels in the pole: 2 feet, gro...
S E Anagnost, C J K Wang


Failure of overhead power transmission and telecommunication poles in Tanzania: Causes, preventive and remedial measures
1988 - IRG/WP 3465
Unless measures are considered urgently to combat massive pole failures occuring in service, it is likely that wooden poles may soon become unpopular. Consequently, pole users may be forced to use costlier alternatives such as underground cables and concrete or steel poles. In trying to countercheck this trend, this paper names the main agents of pole failure, discusses different models of pole fa...
K K Murira


Electricity pole treatments - Wedding Bells State Forest. Inspection September 1983
1985 - IRG/WP 3334
A survey to study the extent of soft rot in hardwood poles in N.S.W. was commenced in 1975. The results of the survey, published in 1982, indicated that a number of factors contributed towards soft rot attack on poles in service. A detailed rest on pole treatments and maintenance procedures was established in 1976, at a site in Wedding Bells State Forest near Coffs Harbour. The site selected was k...
R S Johnstone, R H Eldridge


Soft rot fungi found in copper/chrome/arsenic treated hardwood power transmission poles in Queensland
1978 - IRG/WP 185
In Queensland the effective service life of copper/chrome/arsenic (CCA) treated hardwood telegraph and power transmission poles is being dramatically shortened due to attack by soft rot decay fungi. The Australian Wood Preservation and Pole Industries are funding research into this serious soft rot problem involving C.S.I.R.O. and the University of Queensland. The C.S.I.R.O. is actively engaged wi...
L E Leightley


Hyphal tunnelling of belian (Eusideroxylon zwageri) wood cell walls
1996 - IRG/WP 96-10152
Belian (Eusideroxylon zwageri) is highly regarded among the naturally durable Malaysian hardwoods. Visual inspections at the groundline of belian transmission poles from Sarawak, Malaysia, showed only surface decay of wood after 20 years in service. The cause of decay in belian was investigated by light and transmission electron microscopy. Light microscopy of transverse sections of surface tissue...
A P Singh, A H H Wong


Further studies on soft rot decay in CCA treated Eucalyptus power transmission poles in Queensland, Australia
1980 - IRG/WP 1115
Preliminary results on the examination of fungi isolated from CCA treated Eucalyptus power transmission poles were presented at the 10th Annual IRG Meeting. Since then further examination and identification of fungal isolates has been completed together with screening tests for wood decay ability and tolerance to creosote and CCA and its components. Chemical analyses for CCA retention have also be...
L E Leightley