IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 472 documents. Displaying 25 entries per page.


Evaluating the Exterra Termite Interception and Baiting System in Australia
2003 - IRG/WP 03-20267
The Exterraä Termite Interception and Baiting System (Ensystex Inc., Fayetteville, NC) was evaluated in a field experiment near Townsville, Australia. Cellulose-acetate powder containing either 0.05% weight/weight (w/w) or 0.25% w/w chlorfluazuron (Requiemä) was tested for its efficacy in eradicating colonies of the mound-building subterranean termite Coptotermes acinaciformis (Froggatt). Thirte...
B C Peters, S Broadbent


Field test results for the elimination of subterranean termite (Coptotermes formosanus) colonies by a bait system containing the IGR hexaflumuron
1997 - IRG/WP 97-10222
Field studies were conducted at Chichijima (Ogasawara Islands, Tokyo) to determine the effectiveness of a termite bait system (commercial name: Sentricon* system) containing hexaflumuron (Insect Growth Regulator: IGR) in the elimination of subterranean termite (Coptotermes formosanus) colonies. The level of subterranean termite activity on Ogasawara Islands is high resulting in extensive damage to...
K Suzuki, Y Morita, K Yamauchi


Practical applications of steamed larch wood to a termite bait system using chlorfluazuron
2003 - IRG/WP 03-10464
Less chemical strategies are required for decrease of damages to residents from chemicals such as organic phosphates and carbamates those are usually used to prevent termite attacks on wooden buildings. One of the strategies is a bait system that has already been employed in the termite-infested areas. We tried to use steamed larch wood as a monitor wood and a bait matrix to stimulate feeding acti...
S Doi, S Shibutani, K Hanada, T Miyahara


Termite baiting system: A new dimension of termite control in the Philippines
2007 - IRG/WP 07-10608
The performance of a baiting system and efficacy of an insect growth regulator (IGR), chlorfluazuron, was evaluated against three economically important species of subterranean termites in the Philippines i.e., Coptotermes vastator Light, Microcerotermes losbañosensis Oshima and Macrotermes gilvus Hagen. Preliminary tests were conducted on secondary nests of M. losbañosensis and mounds of M. gil...
C M Garcia, M Y Giron, S G Broadbent


Control of Asian subterranean termites Coptotermes gestroi (Blattodae: Rhinotermitidae) by a new generation bait system with vegetal extracts-diflubenzuron mixture
2023 - IRG/WP 23-30797
The efficacy of anti-termite bait pebble dosed at 0.3% w/w of Diflubenzuron, and Chitin Synthesis Inhibitor (CSI) and 0.6% w/w of vegetal extract from Berkem Biosolutions®, was evaluated in the laboratory on the Asian subterranean termite Coptotermes gestroi (Wasmann). Four concentrations 33.3%, 50%, 50% bis and 100% as well as two neutral matrices, were used in two in-house developed test method...
F Chopinet, D Messaoudi


Trials on the field control of the Formosan subterranean termite with Amdro® bait
1982 - IRG/WP 1163
Amdro® - treated paper towels were introduced into two field colonies of the Formosan subterranean termite in Hawaii. At the concentration of 180 ppm, the toxicant bait was ineffective one month after the introduction. At higher concentrations (> 6,400 ppm), the baits were eaten initially; however, one week after introduction, termites avoided or covered the baits. The 15,000 ppm baits supress...
N-Y Su, M Tamashiro, J R Yates III


Physical barriers and bait toxicants: The Romeo and Juliet of future termite control
1991 - IRG/WP 1503
Soil chemical barriers are considered by some to be the most important technique for protecting buildings against subterranean termites in Australia (and elsewhere), providing a barrier against termite penetration. However, there is no such thing as a barrier that is 100 per cent +protective. And given the worldwide problems of using organochlorine termiticides, public awareness of chemical pollut...
J R J French


Evidence supporting the use of termite baiting systems for long-term structural protection
2000 - IRG/WP 00-10377
The efficacy of the Sentricon Colony Elimination System containing Recruit II termite bait (0.5% hexaflumuron) in controlling active subterranean termite infestations has been demonstrated in numerous studies. This baiting system and other termite baiting systems are now widely used, and generally accepted, tools for remedial termite control in North America, Hawaii, and other parts of the world. ...
J K Grace, N-Y Su


Laboratory evaluation of chemicals as termiticides
1986 - IRG/WP 1293
Laboratory procedures are described for screening chemicals against subterranean termites. Fast-acting compounds with persistent termiticidal activity are identified in tests using a soil substrate, and slower-acting bait toxicants are evaluated in a series of tests using cellulose substrates....
S C Jones


A method for screening termite baits using Coptotermes lacteus mounds
1984 - IRG/WP 1237
A method with several variations designed to rapidly screen potential bait substrates using Coptotermes lacteus mounds is described. The equipment used in this method is relatively inexpensive, readily prepared in the laboratory, and easily installed into active mounds in the field. Bait substrates are in continuous contact with a 'high termite hazard', and may be monitored with ...
J R J French, P J Robinson


Justification for use of mirex in termite control
1988 - IRG/WP 1346
In August 1987, organochlorines were withdrawn in North America from use in termite control. This has left the industry and the community with reduced options in long term protection of wood and wood products. A case is presented to justify the use of the slow-acting stomach termiticide, mirex, under special permit, for use only in the bait-block method of termite control. This method, while not a...
J R J French


A method to evaluate the effeetiveness of bait application using a transferred nest of Coptotermes formosanus Shiraki (Isoptera: Rhinotermitidae)
1999 - IRG/WP 99-20161
Although a survey of monitoring stations can tell us the decline of termite activity after application of baits, it seems questionable to conclude an eradication of a Whole colony of subterranean termites if the termites move out their foraging territory. Only reliable method to ensure the success of bait application is to determine the absence of living termites in their nest in accordance with a...
K Tsunoda, T Yoshimura, H Matsuoka, Y Hikawa


Detection of Acoustic Emission (AE) generated by termite attack in a wooden house
1999 - IRG/WP 99-20166
Recently, considerable attention has been paid to methods for termite control, which involves few or no chemicals. To reduce the amount of termiticide needed, it is necessary to detect termite attack in wood as early as possible. The feasibility of acoustic emission (AE) monitoring for the nondestructive detection of termite attack has been discussed previously. In this study, we propose some tech...
Y Fujii, Y Yanase, T Yoshimura, Y Imamura, S Okumura, M Kozaki


Preference of the Formosan subterranean termite for wood previously damaged by conspecifics
1988 - IRG/WP 1338
In a laboratory choice test, groups of termites from five colonies of Coptotermes formosanus Shiraki were presented with wood blocks which had sustained previous termite damage: 1) by nestmates, 2) by conspecifics from another colony, 3) by another termite species, Reticulitermes virginicus Banks, and 4) no damage. Coptotermes formosanus preferred wood previously damaged by conspecifics over that ...
J P La Fage, K S Delaplane


Colony elimination of Reticulitermes speratus (Kolbe) (Isoptera:Rhinotermitidae) by bait system
1997 - IRG/WP 97-10189
Following a two-year estimation of the foraging populations and territory of Reticulitermes speratus (Kolbe) by triple mark recapture program at Uji campus of Kyoto University, bait stations (commercialized products containing hexaflumuron) were set up in the foraging territory in October 1995 to eliminate the colony. Inspections demonstrated that the number of test stakes with foraging termites d...
K Tsunoda, H Matsuoka, T Yoshimura, K Yamauchi


Tanalith T - a new preservative system for protecting house frames in Australia from termite attack.
2003 - IRG/WP 03-30306
The sawn timber industry in Australia has expressed a desire for a new low cost termite treatment. The treatment needs to be on-line in the dry mill, minimising material handling costs and with a very fast processing time to meet timber flow through the dry mill. The preservative, Tanalith® T, forms an envelope on both Pinus radiata and Pinus elliotti sawn timber. Field trials conducted in Aus...
P R S Cobham, J Snow


Bait box technique for remedial subterranean termite contro
1995 - IRG/WP 95-10115
The bait box technique, as described in this paper, was first used as a method to apply the dust toxicant, arsenic trioxide, to large numbers of aggregated subterranean termites. Over the last twelve years or so the technique has been refined, and in recent years, gained acceptance as an alternative subterranean termite control measure by members of the Australian pest control industry. This baiti...
J R J French, B M Ahmed, D M Ewart


Estimation of oral toxicity of boron as a bait toxicant and the trophallactic effects between individual members of termite colonies.
2003 - IRG/WP 03-10495
In recent years, because of the favourable environmental characteristics of boron, researchers in the wood preservation industries have refocussed on the use of boron as a major wood preservative against wood-destroying insects. Currently the greatest use of boron compounds is in remedial treatments. Boron has been found to have slow-acting toxicity against subterranean termites. Because of thi...
B M Ahmed


Acceleration of boric acid uptake into the subterranean termite, Coptotermes formosanus Shiraki using steamed larch wood
2000 - IRG/WP 00-10353
Laboratory tests were done to measure the efficacy of addition of steamed larch (Larix leptolepis (Sieb. et Zucc.) Gord.) heartwood extracts for the uptake of boric acid against the termite, Coptotermes formosanus Shiraki. Paper discs were treated with the water-soluble fraction obtained from hot-water extracts of steamed larch wood (S-Water) with or without 0.01-2.0% boric acid, followed by expos...
W Ohmura, S Doi, S Ohara


Sulfluramid, a new bait concept for the control of termites
1995 - IRG/WP 95-30075
The annual cost of preventing, controlling and repairing the damage done by termites in the United States of America is in the billions of dollars. Current termite control methodology is generally effective in the control of termite activity. However, new technology (termite foams, termite baits, physical barriers) is emerging which has or will provide new tools to control termites. This report ce...
J B Ballard, T K Porter


Field tests of molybdenum and tungsten baits for termite control
2004 - IRG/WP 04-30345
Molybdenum and tungsten compounds are slow acting to termites and show a high termiticidal efficacy. In our previous papers, we have already reported that those are useful as termiticidal ingredients of bait formulations. The demand for natural rubber is still on the increase. However some kinds of termites inhabiting rubber plantations damage rubber trees and pose a serious threat. To cope with...
Y Katsuda, K Nakayama, C Vongkaluang


The use of the Sentricon Termite Colony Elimination System for controlling termites in difficult control sites in Northern California
2000 - IRG/WP 00-10361
Some termite elimination trials in Northern California with the Sentricon Termite Colony Elimination System are presented - one of a large establish-ment, one of a single family residence with a long history of termite damage, one with a single family residence where other chemical treatments had repeatedly failed, and one single family residence in which the termites had not reached the house but...
D H Kistner, R J Sbragia


Biological resistances of wood-metaborate composites using the borax solution system
2001 - IRG/WP 01-30259
Combinations of wood and metaborate composite were prepared from sapwood specimens of Japanese cedar (Cryptomeria japonica) and the borax and metallic salts system using the diffusion-penetrated process. Wood-metaborate composites were produced as follows: water-saturated specimens were first impregnated by a saturated borax solution and then diffuse-penetrated with Zn2+, Ca2+, or Pb2+ solution. B...
Liang Lin, T Furuno


Laboratory evaluation of JB-TB003 as potential bait toxicant against the subterranean termite, Coptotermes acinaciformis in Australia. subterranean termite, Coptotermes acinaciformis in Australia
1997 - IRG/WP 97-10214
In this laboratory evaluation, Coptotermes acinaciformis actively attacked in the first week of testing Pinus radiata wood blocks (50 x 25 x 15 mm3) treated with concentrations of JB-TB003 (i.e. 25, 50, 100, 200 and 400 ppm); the blocks with highest concentration were the most attractive. Results were similar whether blocks were leached or unleached. The earliest mortality occurred in the 400 ppm ...
B M Ahmed, J R J French, A R Valcke, P Blunt


Field evaluation of several bait toxicants for subterranean termite control: A preliminary report
1988 - IRG/WP 1376
Since 1983, field studies have been conducted to evaluate the effectiveness of several bait toxicants in reducing subterranean termite populations at the Chipola Experimental Forest in Florida. Tests with fenoxycarb (Ro 13-5223), Ro 16-1295, and Avermectin B1 indicated that fenoxycarb showed the most promise. Large numbers of presoldiers and intercastes have continued to occur in plots treated wit...
S C Jones


Next Page